期刊论文详细信息
Acta Polytechnica
COMPARISON OF MATHEMATICAL MODELS FOR HEAT EXCHANGERS OF UNCONVENTIONAL CHP UNITS
Peter Durcansky1 
[1]University of Zilina
关键词: heat exchanger;    CFD simulation;    hot air engine;   
DOI  :  
来源: Czech Technical University in Prague, Faculty of M
PDF
【 摘 要 】
An unconventional CHP unit with a hot air engine is designed as the primary energy source with fuel in the form of biomass. The heat source is a furnace designed for combustion of biomass, whether in the form of wood logs or pellets. The transport of energy generated by the biomass combustion to the working medium of a hot-air engine is ensured by a special heat exchanger connected to this resource. The correct operation of the hot-air engine is largely dependent on an appropriate design of the exchanger. The paper deals with the calculation of the heat exchanger for the applications mentioned, using criterion equations, and based on CFD simulations.
【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201911300923529ZK.pdf 838KB PDF download