Acta Polytechnica | |
Temperature of Steel Columns under Natural Fire | |
P. Studecká1  F. Wald1  L. Kroupa1  | |
关键词: steel structures; fire design; fire test; compartment temperature; protected steel; natural fire; | |
DOI : | |
来源: Czech Technical University in Prague, Faculty of M | |
【 摘 要 】
Current fire design models for time-temperature development within structural elements as well as for structural behaviour are based on isolated member tests subjected to standard fire regimes, which serve as a reference heating, but do not model natural fire. Only tests on a real structure under a natural fire can evaluate future models of the temperature developments in a fire compartment, of the transfer of heat into the structure and of the overall structural behaviour under fire. To study overall structural behaviour, a research project was conducted on an eight storey steel frame building at the Cardington Building Research Establishment laboratory on January 16, 2003. A fire compartment 11×7 m was prepared on the fourth floor. A fire load of 40 kg/m 2was applied with 100 % permanent mechanical load and 65 % of imposed load. The paper summarises the experimental programme and shows the temperature development of the gas in the fire compartment and of the fire protected columns bearing the unprotected floors.
【 授权许可】
Unknown
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201911300840167ZK.pdf | 323KB | download |