Revista Brasileira de Engenharia Agrícola e Ambiental | |
Mapping of potential use of evaporative cooling systems in Southeastern Brazil | |
Carvalho, Valcimar F.1  Silva, Mariano P.2  Yanagi Junior, Tadayuki1  Ferreira, Leandro1  Damasceno, Flávio A.1  | |
[1] UFLA, Lavras;UFV, Viçosa | |
关键词: fogging; thermal index; poultry INTRODUÇÃO A exemplo de Brasil; em climas tropicais e subtropicais; os elevados valores de temperatura de bulbo seco do ar (Tbs) se encontram entre os principais fatores que interferem negativamente na produção de frangos de corte (Tinôco; 1996); | |
DOI : 10.1590/S1415-43662009000300020 | |
学科分类:农业科学(综合) | |
来源: Universidade Federal de Campina Grande * Centro de Ciencias e Tecnologia | |
【 摘 要 】
In present research the potential use of evaporative cooling systems (ECS) associated to tunnel ventilation system (TVS) for broiler reared in Southeastern Brazil was studied. Four configuration systems were tested: (a) TVS, (b) TVS associated to a pad cooling system with 40% efficiency (TVSPAD40), (c) TVS associated to a pad cooling system with 70% efficiency (TVSPAD70) and (d) TVSPAD70 associated to a misting system (TVSPAD70+MIST). Thermal environment was characterized by temperature-humidity index, and the chicken performance was estimated by daily feed intake, daily weight gain and feed conversion. Climatic data from 1980 to 2001, released through Reanalysis-2 Project from NCEP/NCAR were used in this research. The benefitial effect of the use of ECS with TVSPAD70+MIST for providing better production condition was verified, especially during September and October for almost all the southeastern region, mainly in northern and northwestern part of the Minas Gerais State.
【 授权许可】
CC BY-NC
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201911300776900ZK.pdf | 637KB | download |