期刊论文详细信息
Journal of Hand and Microsurgery
Tensile Strength of Flexor Tendon Repair Using Barbed Suture Material in a Dynamic Ex Vivo Model
M. Henle1  R. H. Meffert1  K. Schmidt1  R. K. Zahn1  Philip H. Zeplin1 
[1] Department of Trauma, Hand, Plastic and Reconstructive Surgery, Wuerzburg University Hospital, Oberduerrbacher Str. 6, 97080 Wuerzburg, Germany
关键词: Barbed suture;    Load to failure;    Tenorrhaphy;    Dynamic testing;    Tensile strength;    Ex vivo;   
DOI  :  10.1007/s12593-012-0063-1
学科分类:外科医学
来源: Thieme Medical and Scientific Publishers Pvt. Ltd.
PDF
【 摘 要 】

The purpose of this study was to compare two sutures; a knotted polydioxane with a knotless barbed in a 4-strand Kirchmayr-Kessler suture technique. Human flexor digitorum tendons were separated into four groups. Group 1 – polydioxane; Group 2 - barbed suture; Group 3 and 4 – same as group 1 and 2 with an additional peripheral running suture. In each group the repaired tendons were subjected to linear and cyclical loads. No difference in maximum tensile strength after linear and cyclical force could be detected between the knotted polydioxane suture and the knotless barbed suture. On linear force tests an additional circumferential repair increased the maximum tensile strength of both sutures. Cyclical force loading did not lead to a reduction of maximum strength. Following linear and cyclical loading the 4-strand barbed suture achieved maximum tensile strengths comparable to the 4-strand repair using the polydioxane suture. Barbed suture repair may offer the advantage of knotless suture techniques.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201911300323292ZK.pdf 175KB PDF download
  文献评价指标  