期刊论文详细信息
IJEMS (Indonesian Journal of Environmental Management and Sustainability)
Box Behken design for optimization of COD removal from Palm oil mill effluent (POME) using Reverse osmosis (RO) membrane
Muneer ba Abbad^21  Muhammad Said^12  Siti Rozaimah Sheik Abdullah^33 
[1] Hadhramout University of Science &Technology^2;Sriwijaya University^1;Universiti Kebangsaan Malaysia^3
关键词: POME;    RO membrane;    Box Behken;    COD;   
DOI  :  10.26554/ijems.2019.3.4.39-46
学科分类:地球科学(综合)
来源: ARTS Publishing Corp
PDF
【 摘 要 】

The optimization of COD removal from palm oil mill effluent (POME) using the Reverse Osmosis (RO) membrane was investigated. Experimental conditions for reduce the COD value of POME were achieved successfully using the Box Behken design. The values of affecting factors (POME concentration, pH and Transmembrane pressure were optimized according to the polynomial regression model. The predicted conditions to produce lower COD values were found to be POME concentration (vol. %) =28.30, pH =10.75 and Transmembrane pressure= 0.69 kPa. The predicted of COD value was 24.137 mg/l which in good agreed with experiment value as 25.763 mg/l was obtained.

【 授权许可】

CC BY-NC-SA   

【 预 览 】
附件列表
Files Size Format View
RO201911040042332ZK.pdf 669KB PDF download
  文献评价指标  