期刊论文详细信息
International Journal of Information Technology
Validation of Solar PV Inverter Harmonics Behaviour at Different Power Levels in a Test Network
Wilfred Fritz
关键词: Harmonics;    power quality;    pulse width modulation;    total harmonic distortion.;   
DOI  :  10.1999/1307-6892/10009974
学科分类:计算机应用
来源: World Academy of Science, Engineering and Technology (W A S E T)
PDF
【 摘 要 】

Grid connected solar PV inverters need to be compliant to standard regulations regarding unwanted harmonic generation. This paper gives an introduction to harmonics, solar PV inverter voltage regulation and balancing through compensation and investigates the behaviour of harmonic generation at different power levels. Practical measurements of harmonics and power levels with a power quality data logger were made, on a test network at a university in Germany. The test setup and test results are discussed. The major finding was that between the morning and afternoon load peak windows when the PV inverters operate under low solar insolation and low power levels, more unwanted harmonics are generated. This has a huge impact on the power quality of the grid as well as capital and maintenance costs. The design of a single-tuned harmonic filter towards harmonic mitigation is presented.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910285826570ZK.pdf 553KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:9次