期刊论文详细信息
International Journal of Information Technology
Bipolar PWM and LCL Filter Configuration to Reduce Leakage Currents in Transformerless PV System Connected to Utility Grid
Shanmuka Naga Raju
关键词: Photovoltaic;    PV;    pulse width modulation;    PWM;    perturb and observe;    phase locked loop.;   
DOI  :  10.1999/1307-6892/10009243
学科分类:计算机应用
来源: World Academy of Science, Engineering and Technology (W A S E T)
PDF
【 摘 要 】

This paper  presents PV system without considering transformer connected to electric grid. This is considered more economic compared to present PV system. The problem that occurs when transformer is not considered appears with a leakage current near capacitor connected to ground. Bipolar Pulse Width Modulation (BPWM) technique along with filter L-C-L configuration in the circuit is modeled to shrink the leakage current in the circuit. The DC/AC inverter is modeled using H-bridge Insulated Gate Bipolar Transistor (IGBT) module which is controlled using proposed Bipolar PWM control technique. To extract maximum power, Maximum Power Point Technique (MPPT) controller is used in this model. Voltage and current regulators are used to determine the reference voltage for the inverter from active and reactive current where reactive current is set to zero. The PLL is modeled to synchronize the measurements. The model is designed with MATLAB Simulation blocks and compared with the methods available in literature survey to show its effectiveness.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910282926156ZK.pdf 550KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:22次