期刊论文详细信息
EXCLI Journal
Development of competitive lateral flow immunoassay coupled with silver enhancement for simple and sensitive salivary cortisol detection
Wilasinee Suwanjang2  Amara Apilux3  Sirirat Rengpipat4  Orawon Chailapakul5 
[1] Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok 10330, Thailand;Center for Research and Innovation, Faculty of Medical Technology, Mahidol University, 999 Phutthamonthon 4 Road, Salaya, Nakhon Pathom 73170, Thailand;Department of Clinical Chemistry, Faculty of Medical Technology, Mahidol University, 999 Phutthamonthon 4 Road, Salaya, Nakhon Pathom 73170, Thailand;Department of Microbiology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok 10330, Thailand;Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Patumwan, Bangkok 10330, Thailand
关键词: cortisol;    lateral flow immunoassay;    silver enhancement;    gold nanoparticles;   
DOI  :  10.17179/excli2018-1824
学科分类:过敏症与临床免疫学
来源: University of Mainz, University of Leipzig
PDF
【 摘 要 】

Cortisol is known as a stress biomarker. The measurement of cortisol levels is an early warning indicator for health conditions and diagnosis of stress-related diseases. Herein, a lateral flow immunoassay using a gold nanoparticle label with a silver enhancement system was developed for the simple, sensitive and rapid detection of cortisol. The developed assay was based on a competitive platform of which cortisol-BSA conjugate was immobilized at the test zone to compete with an analyte. The quantitative analysis was performed using gold nanoparticles (AuNPs) as signal labeling. Sequentially, the silver enhancement solution was applied in order to enhance the sensitivity of the assay with the results easily seen by the naked eye. Using this system, the limit of detection (LOD) was found to be 0.5 ng/mL with a 3.6 fold more sensitive detection than without the enhancement system (LOD = 1.8 ng/mL). The salivary cortisol analysis was in the range of 0.5-150 ng/mL (R2 = 0.9984), which is in the clinical acceptable range. For the semi-quantitative analysis, the intensity color of the results was analyzed using an image processing program. The proposed method was successfully applied to detect cortisol in saliva. In addition, the results from our method also complied with the ones of those obtained by using the commercial enzyme-linked immunosorbent assay (ELISA). This developed assay offers great promise for a non-invasive screening test of salivary cortisol.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910280270306ZK.pdf 107KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:15次