期刊论文详细信息
Bulletin of the Korean Chemical Society
Study on the Cause and Mechanism of Repeating Noise According to the Curing Conditions of Electrodeposition Coating
SungUk Choi1  DongUk Lee2 
[1] Body & Trim Development Team Namyang R&D Center, Hyundai Motor Company Gyenggido 445706 Republic of Korea;Department of Industrial Chemistry Pukyong National University Busan 608739 Republic of Korea
关键词: Electrodeposition coating;    Curing;    Noise;    Vibration;    Adhesion;   
DOI  :  10.1002/bkcs.11433
学科分类:化学(综合)
来源: Korean Chemical Society
PDF
【 摘 要 】

In this study, methods and specimens were developed and evaluated to determine the cause of noise resulting from electrodeposition coating penetration. The noise was evaluated using various coating curing temperatures and ambient temperatures. The electrodeposition coating penetrating the gaps exhibited repeating contact, and repeating noise was observed. As a result, it was confirmed that electrodeposition coating undergoes insufficient curing at curing temperatures of 150°C or less. Furthermore, the adhesion strength of the electrodeposition coating surface tends to increase with decreasing curing temperature, thereby increasing the noise magnitude. Consequently, noise is generated by electrodeposition coating penetrating gaps when the coating surfaces are separated due to the stickiness caused by insufficient curing.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910258706707ZK.pdf 85KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:13次