期刊论文详细信息
The Journal of Thoracic and Cardiovascular Surgery
Four-dimensional flow cardiovascular magnetic resonance in aortic dissection: Assessment in an ex vivo model and preliminary clinical experience
Hector W. de Beaufort1  Dipan J. Shah2 
[1] Houston Methodist DeBakey Heart & Vascular Center, Houston, Tex;Thoracic Aortic Research Center, IRCCS Policlinico San Donato, San Donato Milanese, Italy
关键词: aorta;    aortic dissection;    4D-flow MRI;    ex vivo model;   
DOI  :  10.1016/j.jtcvs.2018.06.022
学科分类:心脏病和心血管学
来源: Mosby, Inc.
PDF
【 摘 要 】

ObjectiveFour-dimensional flow cardiovascular magnetic resonance may improve assessment of hemodynamics in patients with aortic dissection. The purpose of this study was to evaluate the feasibility and accuracy of 4-dimensional flow cardiovascular magnetic resonance assessment of true and false lumens flow.MethodsThirteen ex vivo porcine aortic dissection models were mounted to a flow loop. Four-dimensional flow cardiovascular magnetic resonance and 2-dimensional phase-contrast cardiovascular magnetic resonance measurements were performed, assessed for intraobserver and interobserver variability, and compared with a reference standard of sonotransducer flow volume measurements. Intraobserver and interobserver variability of 4-dimensional flow cardiovascular magnetic resonance were also assessed in 14 patients with aortic dissection and compared with 2-dimensional phase-contrast cardiovascular magnetic resonance.ResultsIn the ex vivo model, the intraobserver and interobserver measurements had Lin's correlation coefficients of 0.98 and 0.96 and mean differences of 0.17 (±3.65) mL/beat and −0.59 (±5.33) mL/beat, respectively; 4-dimensional and sonotransducer measurements had a Lin's concordance correlation coefficient of 0.95 with a mean difference of 0.35 (±4.92) mL/beat, respectively. In patients with aortic dissection, the intraobserver and interobserver measurements had Lin's concordance correlation coefficients of 0.98 and 0.97 and mean differences of −0.95 (±8.24) mL/beat and 0.62 (±10.05) mL/beat, respectively; 4-dimensional and 2-dimensional flow had a Lin's concordance correlation coefficient of 0.91 with a mean difference of −9.27 (±17.79) mL/beat because of consistently higher flow measured with 4-dimensional flow cardiovascular magnetic resonance in the ascending aorta.ConclusionsFour-dimensional flow cardiovascular magnetic resonance is feasible in patients with aortic dissection and can reliably assess flow in the true and false lumens of the aorta. This promotes potential future work on functional assessment of aortic dissection hemodynamics.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910255212003ZK.pdf 3942KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:13次