The Journal of Engineering | |
Capacity guaranteed control method for air conditioning cluster joining power grid frequency regulation | |
Zihao Li1  Wenchuan Wu2  | |
[1] Department of Electrical Engineering , Tsinghua University , Beijing , People's Republic of China | |
关键词: buildings; power grid frequency regulation; secondary frequency control; AC aggregations; AC cluster; houses; secondary frequency regulation service; primary frequency control; air conditioning cluster; virtual power plant; load frequency control; heuristic simulated search algorithm; | |
DOI : 10.1049/joe.2018.8348 | |
学科分类:工程和技术(综合) | |
来源: IET | |
【 摘 要 】
For the thermal inertia of houses and buildings, air conditioning (AC) cluster shows the potential in load frequency control. In this study, the authors propose a complete control framework for friendly accepting ACs to participate in secondary frequency regulation service without causing discomfort. An aggregator is hired to continually estimate the regulation capacity of ACs cluster by a heuristic simulated search algorithm, which could be guaranteed in a given duration. The external characteristics of the AC aggregations are set like a virtual power plant, which takes a droop curve for primary frequency control and a translation character for secondary frequency control. Simulation shows the capability for AC aggregations in load frequency control.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201910254149705ZK.pdf | 3270KB | download |