期刊论文详细信息
Frontiers in Energy Research
Startup Thermal Analysis of a Supercritical-Pressure Light Water-Cooled Reactor CSR1000
Shan, Jianqiang1  Yuan, Yuan2 
[1] School of Nuclear Science and Technology, Xian Jiaotong University, China;Sino-French Institute of Nuclear Engineering and Technology, Sun Yat-sen University, China
关键词: Supercritical water reactor;    SCTRAN;    Heat transfer coefficients;    heat transfer;    control system;    Startup;   
DOI  :  10.3389/fenrg.2018.00127
学科分类:能源(综合)
来源: Frontiers
PDF
【 摘 要 】

Supercritical-pressure light water-cooled reactors (SCWR) are the only water cooled reactor types in Generation IV nuclear energy systems. Startup systems, and their associated startup characteristic analyses, are important components of the SCWR design. To analyze the entire startup system, we propose a wall heat transfer model in a paper, based on the results from a supercritical transient analysis code named SCTRAN developed by Xi’an Jiao tong Tong University. In this work, we propose a new heat transfer mode selection process. Additionally, the most appropriate heat transfer coefficient selection method is chosen from existing state-of-the-art methods. Within the model development section of the work, we solve the problem of discontinuous heat transfer coefficients in the logic transformation step. When the pressure is greater than 19 Mpa, a look-up table method is used to obtain the heat transfer coefficients with the best prediction accuracy across the critical region. Then, we describe a control strategy for the startup process that includes a description of the control objects for coolant flow rate, heat-exchange outlet temperature, system pressure, core thermal power, steam drum water-level and the once-through direct cycle loop inlet temperature. Different control schemes are set-up according to different control objectives of the startup phases. Based on CSR1000 reactor, an analytical model, which includes a circulation loop and once-through direct cycle loop is established, and four startup processes, with control systems, are proposed. The calculation results show that the thermal parameters of the circulation loop and the once-through direct cycle meets all expectations. The maximum cladding surface temperature remains below the limit temperature of 650℃. The feasibility of the startup scheme and the security of the startup process are verified.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910253795330ZK.pdf 3393KB PDF download
  文献评价指标  