Preoperative Topical Intranasal Fluorescein in Diagnosis of Cerebrospinal Fluid Rhinorrhea
Saboori, Masih1  Amini, Zhale2  Hashemi Jazi, Seyed Mostafa3  Raisi, Mostafa4 
[1] Department of Internal Medicine, Isfahan University of Medical Sciences, Isfahan, Iran;Department of Neurosurgery, Isfahan University of Medical Sciences, Isfahan, Iran;Department of Otolaryngology, Isfahan University of Medical Sciences, Isfahan, Iran;Poursina Hakim Digestive Disease Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
关键词: cerebrospinal fluid;    endoscope;    fluorescein;    Intrathecal;    rhinorrhea;    skull base;    Topical;   
DOI  :  10.4103/atr.atr_87_18
学科分类:医学(综合)
来源: Kashan University of Medical Sciences
PDF
【 摘 要 】

Background and Objectives: The preoperative diagnosis of cerebrospinal fluid (CSF) leak site is necessary for the management of CSF rhinorrhea. At present, intrathecal fluorescein is a common approach for it; however, regarding drawbacks, its value is limited. This study aimed at examining the effects of topical intranasal fluorescein (TINF) on the preoperative diagnosis of CSF rhinorrhea and intraoperative localization of CSF fistula. Patients and Methods: In this cross‑sectional study, 32 consecutive patients with CSF rhinorrhea were recruited. Topical intranasal 10% fluorescein was placed in common sites of leakage, the middle turbinate meatus, the roof of the ethmoid plate, and sphenoethmoidal recesses. Change of the color of fluorescein indicated the presence of CSF, and thus, the site of the fistula could be outlined. The accuracy rates of diagnosis of leak site identified by TINF were compared with those by available imaging modalities, CSF analysis, intraoperative findings, and follow‑up. Results: The cause of the leak was traumatic in 22 patients and nontraumatic in 10 patients. Preoperative accuracy rate of the location of CSF fistula was estimated 58.3% by available imaging study. The preoperative diagnosis rate of CSF rhinorrhea and the CSF fistula site localization rate by TINF were both 100%. No recurrence was found during the follow‑up for 2–12 months. No complication had been reported. Conclusions: Preoperative TINF is an easy, quick, sensitive, safe, and accurate tool in localization of the site of the CSF fistulas and can be considered as a viable noninvasive alternative to the intrathecal fluorescein technique for preoperative diagnosis of CSF rhinorrhea.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201910253245150ZK.pdf 373KB PDF download