期刊论文详细信息
Malaria Journal
Detection of low-density Plasmodium falciparum infections using amplicon deep sequencing
  1    2    2    2    2    2    2    3 
[1] grid.66859.34, Genomics Platform, Broad Institute of MIT and Harvard, 02142, Cambridge, MA, USA;grid.66859.34, Infectious Disease and Microbiome Program, Broad Institute of MIT and Harvard, 02142, Cambridge, MA, USA;000000041936754X, grid.38142.3c, Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, 02115, Boston, MA, USA;grid.66859.34, Infectious Disease and Microbiome Program, Broad Institute of MIT and Harvard, 02142, Cambridge, MA, USA;000000041936754X, grid.38142.3c, Department of Immunology and Infectious Diseases, Harvard T.H. Chan School of Public Health, 02115, Boston, MA, USA;College of Natural, Behavioral, and Health Sciences, Simmons University, 02115, Boston, MA, USA;
关键词: Targeted amplicon deep sequencing;    Haplotype calling;    Multiplicity of infection;    Multiclonal infection;    Within-host diversity;    Molecular epidemiology;    Molecular surveillance;    Malaria;    Plasmodium;   
DOI  :  10.1186/s12936-019-2856-1
来源: publisher
PDF
【 摘 要 】

BackgroundDeep sequencing of targeted genomic regions is becoming a common tool for understanding the dynamics and complexity of Plasmodium infections, but its lower limit of detection is currently unknown. Here, a new amplicon analysis tool, the Parallel Amplicon Sequencing Error Correction (PASEC) pipeline, is used to evaluate the performance of amplicon sequencing on low-density Plasmodium DNA samples. Illumina-based sequencing of two Plasmodium falciparum genomic regions (CSP and SERA2) was performed on two types of samples: in vitro DNA mixtures mimicking low-density infections (1–200 genomes/μl) and extracted blood spots from a combination of symptomatic and asymptomatic individuals (44–653,080 parasites/μl). Three additional analysis tools—DADA2, HaplotypR, and SeekDeep—were applied to both datasets and the precision and sensitivity of each tool were evaluated.ResultsAmplicon sequencing can contend with low-density samples, showing reasonable detection accuracy down to a concentration of 5 Plasmodium genomes/μl. Due to increased stochasticity and background noise, however, all four tools showed reduced sensitivity and precision on samples with very low parasitaemia (< 5 copies/μl) or low read count (< 100 reads per amplicon). PASEC could distinguish major from minor haplotypes with an accuracy of 90% in samples with at least 30 Plasmodium genomes/μl, but only 61% at low Plasmodium concentrations (< 5 genomes/μl) and 46% at very low read counts (< 25 reads per amplicon). The four tools were additionally used on a panel of extracted parasite-positive blood spots from natural malaria infections. While all four identified concordant patterns of complexity of infection (COI) across four sub-Saharan African countries, COI values obtained for individual samples differed in some cases.ConclusionsAmplicon deep sequencing can be used to determine the complexity and diversity of low-density Plasmodium infections. Despite differences in their approach, four state-of-the-art tools resolved known haplotype mixtures with similar sensitivity and precision. Researchers can therefore choose from multiple robust approaches for analysing amplicon data, however, error filtration approaches should not be uniformly applied across samples of varying parasitaemia. Samples with very low parasitaemia and very low read count have higher false positive rates and call for read count thresholds that are higher than current default recommendations.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910109893866ZK.pdf 1745KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:5次