期刊论文详细信息
The Journal of Engineering
DAB-based PET in MVDC traction and shipboard applications with distribution and redundant control
  1    1    1 
[1] Department of Electrical Engineering, Tsinghua University, Beijing, People's Republic of China;
关键词: voltage control;    ships;    power convertors;    power electronics;    power transformers;    DC-DC power convertors;    AC-DC power convertors;    DAB-based PET;    shipboard applications;    redundant control;    medium-voltage DC grid;    traction;    large-scale ships;    lower loss;    higher reliability;    higher controllability;    simpler system architecture;    key elements;    MVDC grid;    power electronic transformers;    great advantage;    relatively smaller volume;    higher flexibility;    traditional line transformers;    AC/DC converters;    distribution DC PET;    input series output parallel dual active bridge;    power supply system;    12 DABs;    input voltage;    output voltage;    distributed voltage balancing;    redundancy control;    great controllability;    redundant modules;    great reliability;    voltage 10.0 kV;    voltage 380.0 V;   
DOI  :  10.1049/joe.2018.8439
来源: publisher
PDF
【 摘 要 】

Medium-voltage DC (MVDC) grid has drawn more interest in the application of traction and large-scale ships, for its lower loss, higher reliability, higher controllability and simpler system architecture. DC breaker and DC distribution are the key elements in the MVDC grid, and the power electronic transformers (PETs) have shown great advantage in the MVDC grid for its relatively smaller volume and higher flexibility compared to the traditional line transformers and AC/DC converters. In this study, a distribution DC PET based on input series output parallel dual active bridge (DAB) is proposed in the application of power supply system in traction and large scale ships. The DC PET consists of 12 DABs with an input voltage of 10 kV and the output voltage of 380 V. Strategies are proposed for distributed voltage balancing and redundancy control in the proposed PET. Simulations were done in MATLAB/Simulink. In the simulation, waveforms in the normal working conditions and the module fault status is shown, and the result shows that the proposed DC PET has great controllability and flexibility and by adding redundant modules, it keeps great reliability while fault occurs.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201910106510527ZK.pdf 1819KB PDF download
  文献评价指标  
  下载次数:1次 浏览次数:3次