| The Journal of Engineering | |
| Alternate arm modular multilevel converter energy balancing via overlap onset control | |
|   1    2    3  | |
| [1] Department of Electrical and Computer Engineering, University of Manitoba, Winnipeg, Canada;Manitoba Hydro, Winnipeg, Canada;RTDS Technologies, Winnipeg, Canada; | |
| 关键词: EMTP; power system simulation; power system CAD; zero current switching; HVDC power convertors; voltage control; switching convertors; power capacitors; overlap onset control; AAC commutation; output voltage quality; steady-state converter models; capacitor voltage regulation method; AAC operating range; alternate arm modular multilevel converter; OOCs; energy balancing; submodule voltage regulation; zero-current switching controls; electromagnetic transient simulation; PSCAD-EMTDC; | |
| DOI : 10.1049/joe.2018.8787 | |
| 来源: publisher | |
PDF
|
|
【 摘 要 】
This study introduces a novel method called overlap onset control (OOC) to balance and maintain alternate arm modular multilevel converter (AAC) submodule capacitor voltages at their desired value. OOC performs zero-current switching and controls the timing of AAC commutation to regulate submodule voltages while retaining output voltage quality. The study uses steady-state converter models to develop the mathematical foundations behind the proposed capacitor voltage regulation method and then presents electromagnetic transient simulation results in PSCAD/EMTDC to demonstrate OOC's ability to extend the AAC operating range.
【 授权许可】
CC BY
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201910105075397ZK.pdf | 5099KB |
PDF