【 摘 要 】
Mixed incineration of municipal solid waste (MSW) in existing coal gangue power plant is a potentially high-efficiency and low-cost MSW disposal way. In this paper, the co-combustion and pollutants emission characteristic of MSW and coal gangue was investigated in a circulating fluidized bed (CFB) combustor. The effect of MSW blend ratio, bed temperature and excess air ratio was detailedly studied. The results show the NOx and HCl emission increases with the increasing MSW blend ratio and the SO2 emission decreases. With the increase of bed temperature, the CO emission decreases while the NOx and SO2 emission increases. The HCl emission is nearly stable in the temperature range of 850–950 °C. The increase of excess air ratio gradually increases the NOx emission but has no significant effect on the SO2 emission. The HCl emission firstly increases and then decreases with the increase of excess air ratio. For a typical CFB operating condition with excess air ratio of 1.4, bed temperature of 900 °C and MSW blend ratio of 10%, the original CO, NOx, SO2 and HCl emissions are 52, 181, 3373 and 58 mg/N m3 respectively.
【 授权许可】
CC BY
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
RO201910101178780ZK.pdf | 951KB | download |