期刊论文详细信息
The Permanente Journal
Bilateral Large Pneumothoraxes Following Implantable Cardioverter-Defibrillator Generator Change: A Case Report ofan Uncommon Event Complicating a Common Procedure
Ritin Bomb, MD, FACC1 
关键词: Bilateral Large Pneumothoraxes Following Implantable Cardioverter-Defibrillator Generator Change A Case Report ofan Uncommon Event Complicating a Common Procedure;   
DOI  :  10.7812/TPP/16-086E-pub: 06/19/2" />
学科分类:医学(综合)
来源: Permanente Medical Group
PDF
【 摘 要 】

Introduction: A bilateral large spontaneous pneumothorax to our knowledge has never been reported after a device implantation. We report an unusual case of a patient developing spontaneous bilateral large pneumothoraxes after an implantable cardioverter-defibrillator generator and lead revision without evidence of any obvious traumatic cardiac injury.Case Presentation: A 79-year-old white man was scheduled for implantable cardioverter-defibrillator generator change and addition of an atrial lead. Approximately one hour after the procedure, he suddenly went into respiratory distress with profuse sweating, and pallor with falling oxygen saturation and blood pressure. Chest x-ray showed bilateral large pneumothoraxes.Discussion: In our literature search, we found no reports of large bilateral pneumothorax in the absence of any traumatic cardiac or lung injury. Rupture of bilateral pleura during subclavian access or presence of pleuropleural communication or a right atrial microperforation could be possible causes.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201904281554095ZK.pdf 22535KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:34次