期刊论文详细信息
Journal of Water Reuse and Desalination
Synthetic organic polymer fouling in municipal wastewater reuse reverse osmosis
Veenendaal, G.1  Msuya, M.2  Ekowati, Y.2  Salinas Rodriguez, S. G.2  Schippers, J. C.2  Kennedy, M. D.2 
[1] NieuWater BV, Postbus 18, 9400 AA Assen, The Netherlands and WMD Water, Lauwers 3, 9405 BL Assen, The Netherlands;UNESCO-IHE Institute for Water Education, Westvest 7, 2611 AX Delft, The Netherlands
关键词: cationic synthetic polymers;    fouling;    reverse osmosis;    wastewater reuse;   
DOI  :  10.2166/wrd.2014.046
学科分类:工程和技术(综合)
来源: IWA Publishing
PDF
【 摘 要 】

A full scale waste water reuse plant suffered from irreversible fouling of the reverse osmosis (RO) membranes. The major suspect of fouling is cationic organic polymers applied in the wastewater sludge treatment. Thus, the purpose of this research is to study the effect of six cationic polymers, applied in the plant, on RO membrane performance. The filtration and adsorption experiments with 4 mg C/L polymer solutions were performed in laboratory RO set ups for 5–7 days. Scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were used to analyze polymers. Fouling prediction was calculated with Modified Fouling Index-ultrafiltration (MFI-UF) constant flux values. A flux decline of 30–50% was observed after filtration experiments. In adsorption experiments, the resistance increased from 6 to 35%. The MFI-UF results showed the rate of fouling was around 1 bar/month. The base-acid cleaning was able to reduce the resistance of the fouled membrane with irreversible fouling resistance, 6–7%. SEM images showed that the fouling layer after cleaning did not appear in the membrane. The FTIR spectra of the membrane after cleaning were similar to virgin membrane. However, several adsorption peaks on the membrane after cleaning were not restored to the initial state.

【 授权许可】

CC BY-NC-ND   

【 预 览 】
附件列表
Files Size Format View
RO201904022428308ZK.pdf 585KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:12次