| 卷:196 | |
| Novel analytical procedure using a combination of hollow fiber supported liquid membrane and dispersive liquid-liquid microextraction for the determination of aflatoxins in soybean juice by high performance liquid chromatography - Fluorescence detector | |
| Simao, Vanessa ; Merib, Josias ; Dias, Adriana N. ; Carasek, Eduardo | |
| Univ Fed Santa Catarina | |
| 关键词: Hollow fiber supported liquid membrane; Dispersive liquid-liquid microextraction; Soybean juice; Aflatoxins; Sample preparation; | |
| DOI : 10.1016/j.foodchem.2015.09.018 | |
| 学科分类:食品科学和技术 | |
PDF
|
|
【 摘 要 】
This study describes a combination between hollow fiber membrane and dispersive liquid-liquid microextraction for determination of aflatoxins in soybean juice by HPLC. The main advantage of this approach is the use of non-chlorinated solvent and small amounts of organic solvents. The optimum extraction conditions were 1-octanol as immobilized solvent; toluene and acetone at 1:5 ratio as extraction and disperser solvents (100 mu L), NaCl at 2% of the sample volume and extraction time of 60 min. The optimal condition for the liquid desorption was 150 mu L acetonitrile:water (50:50 v/v) and desorption time of 20 min. The linear range varied from 0.03 to 21 mu g L-1, with R-2 coefficients ranging from 0.9940 to 0.9995. The limits of detection and quantification ranged from 0.01 mu g L-1 to 0.03 mu g L-1 and from 0.03 mu g L-1 to 0.1 mu g L-1, respectively. Recovery tests ranged from 72% to 117% and accuracy between 12% and 18%. (C) 2015 Elsevier Ltd. All rights reserved.
【 授权许可】
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| JA201706070002932K.pdf | KB |
PDF