期刊论文详细信息
Acta Chromatographicae
Development of an innovative gas chromatography-mass spectrometry method for assessment of formaldehyde in the workplace atmosphere
Dugheri Stefano1  Pompilio Ilenia2  Montalti Manfredi2  Arcangeli Giulio2  Mucci Nicola2  Colpo Marco3 
[1] 1Laboratorio di Igiene e Tossicologia Industriale, Azienda Ospedaliero-Universitaria Careggi, Largo P. Palagi 1, 50100 Firenze, ItalyAuthor for correspondence: stefano.dugheri@unifi.it ,Bonari Alessandro @@2Dipartimento di Medicina Sperimentale e Clinica, Università degli Studi di Firenze, Largo G.A. Brambilla 3, 50139 Firenze, Italy;2Dipartimento di Medicina Sperimentale e Clinica, Università degli Studi di Firenze, Largo G.A. Brambilla 3, 50139 Firenze, Italy;3Dipartimento di Statistica, Informatica e Applicazioni, Università degli Studi di Firenze, Viale G.B. Morgagni 67, 50139 Firenze, Italy
关键词: Formaldehyde;    fast gas chromatography;    air sampling;    automation;   
DOI  :  10.1556/1326.2016.00102
学科分类:化学(综合)
来源: Akademiai Kiado Rt.
PDF
【 摘 要 】

World consumption of formaldehyde (FA) is forecast to grow at an average annual rate of about 4% from 2015 to 2020 with world production to exceed 52 million tons in 2017. From the first day of January 2016, the Commission Regulation No. 91/2015 established the FA classification through an indication from European Chemical Agency as category 2 mutagenic and category 1B carcinogen. A novel method for the determination of gaseous FA in air is presented herewith. The sampling was carried out using a miniaturized cartridge by means of a medium-flow pumping system (1.0 L min-1, 5–60 min) and absorption of FA vapors on 2,4-dinitrophenylhydrazine. Cartridge desorption removing the excess derivatizing agent based upon solid-phase extraction was performed by an innovative xyz robotic system on-line with fast gas chromatography (GC)—mass spectrometry (MS). Through the generation of standard atmospheres of known concentration of FA, we evaluated the precision (relative standard deviation for n = 10, 8.8%), lower limit of quantification (0.072 µg/cartridge), and linearity (from 0.125—64 µg/cartridge with correlation coefficient of 0.99) of the method. The described procedure combines the efficiency of fast GC—MS systems with both the high throughput of autosampler and the quantitative accuracy of FA-dinitrophenylhydrazone for measuring American Conference of Governmental Industrial Hygienists TLV Ceiling.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201902186370775ZK.pdf 5593KB PDF download
  文献评价指标  