| Archives of Thermodynamics | |
| The influence of external cooling system on the performance of supercritical steam turbine cycles | |
| Wojciech KosmanInstitute of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, PolandOther articles by this author:De Gruyter OnlineGoogle Scholar1  | |
| [1] Institute of Power Engineering and Turbomachinery, Silesian University of Technology, Konarskiego 18, 44-100 Gliwice, Poland | |
| 关键词: Keywords: Steam turbine; Supercritical steam; Cooling; Efficiency; | |
| DOI : 10.2478/v10173-010-0019-4 | |
| 学科分类:能源(综合) | |
| 来源: Polska Akademia Nauk * Oddzial w Gdansku, Instytut Maszyn Przeplywowych / Polish Academy of Sciences, Institute of Fluid-Flow Machinery | |
PDF
|
|
【 摘 要 】
The problem presented in this paper refers to the concepts applied to the design of supercritical steam turbines. The issue under the investigation is the presence of a cooling system. Cooling systems aim to protect the main components of the turbines against overheating. However the cooling flows mix with the main flow and modify the expansion line in the steam path. This affects the expansion process in the turbine and changes the performance when compared to the uncooled turbine. The analysis described here investigates the range of the influence of the cooling system on the turbine cycle. This influence is measured mainly through the change of the power generation efficiency. The paper explains the approach towards the assessment of the cooling effects and presents results of the modeling for three supercritical steam cycles.
【 授权许可】
Unknown
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| RO201902182369453ZK.pdf | 26KB |
PDF