期刊论文详细信息
Bulletin of the Polish Academy of Sciences. Technical Sciences
Full-bridge MMC DC fault ride-through and STATCOM operation in multi-terminal HVDC grids
G. TsolaridisAalborg University, Aalborg, DenmarkOther articles by this author:De Gruyter OnlineGoogle Scholar1  R. TeodorescuAalborg University, Aalborg, DenmarkOther articles by this author:De Gruyter OnlineGoogle Scholar1  P. BauerDelft University of Technology, Delft, The NetherlandsOther articles by this author:De Gruyter OnlineGoogle Scholar2  E. KontosCorresponding authorDelft University of Technology, Delft, The NetherlandsEmailOther articles by this author:De Gruyter OnlineGoogle Scholar2 
[1] Aalborg University, Aalborg, Denmark;Delft University of Technology, Delft, The Netherlands
关键词: Keywords: DC current control;    DC fault;    HVDC converters;    HVDC transmission;    MMC;    multiterminal networks;    STATCOM;   
DOI  :  10.1515/bpasts-2017-0070
学科分类:工程和技术(综合)
来源: Polska Akademia Nauk * Centrum Upowszechniania Nauki / Polish Academy of Sciences, Center for the Advancement of Science
PDF
【 摘 要 】

This paper investigates a control structure to enhance the DC fault ride-through capability of a full-bridge modular multilevel converter (MMC) station, while ensuring a stable controlled operation as a STATCOM during DC faults without the need for fault isolation. Taking advantage of the switching states of a full-bridge submodule, a DC current controller is proposed, which provides the DC voltage reference for the modulation when a DC fault is detected. By changing the outer controllers strategy from DC voltage or active power control to converter energy control during a fault, the decoupling of the converter operation from the DC side dynamics is realized. In this paper, the focus is on the control methodology at all times of operation and the evaluation of the STATCOM control during a fault. To this end, extensive simulations were performed on a three-terminal high voltage direct current (HVDC) grid in radial configuration and a pole-to-pole DC fault case was investigated. The results showed that the AC voltage and current were controlled within limits at all times, while the full-bridge MMC was able to provide reactive power support to the AC grid. Moreover, using the proposed control methodology, the transients at the operation transition points between STATCOM and inverter/rectifier operation were minimized and the stations were able to safely ride through the fault.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201902182020749ZK.pdf 4093KB PDF download
  文献评价指标  
  下载次数:26次 浏览次数:23次