期刊论文详细信息
Archives of Thermodynamics
Changes of the thermodynamic parameters in failure conditions of the micro-CHP cycle
Eugeniusz IhnatowiczThe Szewalski Institute of Fluid Flow Machinery of Polish Academy of the Sciences, Fiszera 14, 80-231 Gda?sk, PolandOther articles by this author:De Gruyter OnlineGoogle Scholar1  Robert MatyskoCorresponding authorThe Szewalski Institute of Fluid Flow Machinery of Polish Academy of the Sciences, Fiszera 14, 80-231 Gda?sk, PolandEmailOther articles by this author:De Gruyter OnlineGoogle Scholar1  Jaros?aw MikielewiczThe Szewalski Institute of Fluid Flow Machinery of Polish Academy of the Sciences, Fiszera 14, 80-231 Gda?sk, PolandOther articles by this author:De Gruyter OnlineGoogle Scholar1 
[1] The Szewalski Institute of Fluid Flow Machinery of Polish Academy of the Sciences, Fiszera 14, 80-231 Gda?sk, Poland
关键词: Keywords: Micro-CHP system;    Transient model;    Failure states;    Multifuel boiler system;    Heating system;   
DOI  :  10.2478/aoter-2014-0003
学科分类:能源(综合)
来源: Polska Akademia Nauk * Oddzial w Gdansku, Instytut Maszyn Przeplywowych / Polish Academy of Sciences, Institute of Fluid-Flow Machinery
PDF
【 摘 要 】

The paper presents the calculations for the failure conditions of the ORC (organic Rankine cycle) cycle in the electrical power system. It analyses the possible reasons of breakdown, such as the electrical power loss or the automatic safety valve failure. The micro-CHP (combined heat and power) system should have maintenance-free configuration, which means that the user does not have to be acquainted with all the details of the ORC system operation. However, the system should always be equipped with the safety control systems allowing for the immediate turn off of the ORC cycle in case of any failure. In case of emergency, the control system should take over the safety tasks and protect the micro-CHP system from damaging. Although, the control systems are able to respond quickly to the CHP system equipped with the inertial systems, the negative effects of failure are unavoidable and always remain for some time. Moreover, the paper presents the results of calculations determining the inertia for the micro-CHP system of the circulating ORC pump, heat removal pump (cooling condenser) and the heat supply pump in failure conditions.

【 授权许可】

Unknown   

【 预 览 】
附件列表
Files Size Format View
RO201902181670083ZK.pdf 588KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:21次