期刊论文详细信息
The Journal of Engineering
Performance evaluation of a transformerless multiphase electric submersible pump system
Ahmed A. Hakeem1  Ayman Samy Abdel-Khalik1  Ahmed Abbas Elserougi1  Shehab Ahmed2  Ahmed Mohamed Massoud3 
[1] Department of Electrical Engineering, Alexandria University, Alexandria, Egypt;ECEN Department, Texas A&M University at Qatar, Doha, Qatar
关键词: sinusoidal output voltage;    filter networks;    low-voltage variable-frequency drive;    five-phase modular winding induction machine;    transformerless multiphase electric submersible pump system;    filter-less operation;    overvoltage problems;    boost-inverter;    voltage boosting capability;    step-up transformer;    travelling wave phenomenon;   
DOI  :  10.1049/joe.2014.0148
学科分类:工程和技术(综合)
来源: IET
PDF
【 摘 要 】

Using of low-voltage variable-frequency drive followed by a step-up transformer is the most preferable way to feed an electrical submersible pump motor. The existence of long feeder between the motor and drive systems usually causes over-voltage problems because of the travelling wave phenomenon, which makes the employment of filter networks on the motor or inverter terminals mandatory. The so-called boost-inverter inherently can solve this problem with filter-less operation as it offers a direct sinusoidal output voltage. As boost inverters have voltage boosting capability, it can provide a transformer-less operation as well. This study investigates the performance of a five-phase modular winding induction machine fed from a boost-inverter through a long feeder. A simulation study using a 1000 Hp system and experimental investigation on a 1 Hp prototype machine are used to support the presented approach.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201902022961051ZK.pdf 845KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:6次