期刊论文详细信息
Proceedings of the International Conference on Coastal Engineering
SEISMIC STABILITY OF CAISSON TYPE BREAKWATER
Zeynep Tugce Yuksel1  yalcin yuksel2  Burak Aydogan2 
[1] MAG Engineering Services;Yildiz Technical University
关键词: caisson type breakwater;    shaking tank;    Newmark sliding method;   
DOI  :  10.9753/icce.v35.structures.8
学科分类:建筑学
来源: Coastal Engineering Research Council
PDF
【 摘 要 】

In recent two decades, more and more marine structures, such as breakwater, bridge, oil platform and turbines are constructed on seabed in offshore area. The stability of these marine structures after construction under the environmental loading is the main concern for the coastal engineers involved in the design work. Generally, there are two types of environmental loading in offshore area. One of them is the ocean wave and the other is the possible earthquake. Ocean wave is the conventional loading for all marine structures. However, little attention and investigation has been paid for the second type of environmental loading-seismic wave and conducted in the previous literatures. In this study, an experimental study was carried out for the stability of caisson type breakwater located on a firm bed condition under regular harmonic seismic wave. The results obtained from this experimental study were also used for the verification of the newly modified sliding block analysis model.

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201902019802184ZK.pdf 1042KB PDF download
  文献评价指标  
  下载次数:27次 浏览次数:1次