期刊论文详细信息
Foot & Ankle Orthopaedics
3D biometrics for hindfoot alignment using Weight Bearing CT: a prospective assessment of 140 feet
FrancoisLintz1 
关键词: weight bearing CT hindfoot ankle alignment cone beam 3D biometrics;   
DOI  :  10.1177/2473011418S00323
学科分类:医学(综合)
来源: Sage Journals
PDF
【 摘 要 】

Category:HindfootIntroduction/Purpose:Hindfoot alignment is an important reference for foot and ankle surgery, and the Foot Ankle Offset (FAO) using semi-automatic software has been reported as a valuable hindfoot alignment measurement in weightbearing CT(WBCT). The objective was to assess the clinical relevance and reproducibility of the FAO value for hindfoot alignment and compare it with previous findings.Methods:A prospective study was conducted, with ethics committee approval. Patients were included, clinically examined and divided into 3 groups: normal alignment (Group 1), valgus (Group 2), varus (Group 3). A continuous series of 140 feet (71 patients) were referred from September to December 2017 (65 normal, 41 valgus, and 34 varus). All patients had a bilateral weight bearing CT, and the FAO values were recorded. The long axial view angle(HAct)was measured on Digitally Reconstructed Radiographs (DRR) as comparison. All values were measured and compared by two different investigators. The reproduci...

【 授权许可】

CC BY   

【 预 览 】
附件列表
Files Size Format View
RO201901218430156ZK.pdf 204KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:9次