期刊论文详细信息
Zhongxiyi Jiehe Huli (Zhong-Yingwen Ban)
容积输液泵联合高精密过滤输液器在预防静脉泵入盐酸艾司洛尔致静脉炎中的应用
何兵1 
关键词: 盐酸艾司洛尔;    容积输液泵;    过滤器;    静脉炎;    疼痛;    静脉输液;   
DOI  :  10.11997/nitcwm.2017011031
学科分类:护理学
来源: Shanghai Jiao Tong University Press
PDF
【 摘 要 】

Abstract:Objective To evaluate the application of Infusomat(R)Space Pump combined with precise filtering infusion apparatus in prevention of phlebitis caused by esmolol hydrochloride in intravenous solution. Methods 〓Totally 100 patients receiving esmolol hydrochloride in intravenous solution were assigned to the group A(n=34), group B(n=33)and group C(n=33). In group A, the Infusomat(R)Space Pump combined with precise filtering infusion apparatus was used in intravenous infusion. In group B, the Infusomat(R)Space Pump combined with normal infusion apparatus was used. In group C, the micro-injection pump combined with extension tube was used. The incidence of phlebitis, occurrence time of phlebitis and pain degree during infusion were compared among three groups. Results 〓The incidence of phlebitis was lower in the group A than that in group B and group C(P<0.05). Patients in the group A had a later occurrence time of phlebitis compared with those in the group B and group C(P<0.05). Patients in the group A suffered a less severity of pain during infusion compared with those in the group B and group C. Conclusion 〓By Infusomat(R)Space Pump combined with precise filtering infusion apparatus is effective to prevent phlebitis caused by esmolol hydrochloride in intravenous solution,.

【 授权许可】

CC BY-NC   

【 预 览 】
附件列表
Files Size Format View
RO201901217090207ZK.pdf 1061KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:5次