| Radiation Oncology | |
| Analysis of motion of the rectum during preoperative intensity modulated radiation therapy for rectal cancer using cone-beam computed tomography | |
| Keiichi Nakagawa1  Kuni Otomo1  Akihiro Haga1  Akira Sakumi1  Ryousuke Takenaka1  Hideomi Yamashita1  | |
| [1] Department of Radiology, University of Tokyo Hospital, 7-3-1, Hongo, Tokyo 113-8655, Bunkyo-ku, Japan | |
| 关键词: SIB; IMRT; CBCT; Rectal cancer; Rectal motion; | |
| Others : 1150297 DOI : 10.1186/s13014-014-0311-6 |
|
| received in 2014-06-28, accepted in 2014-12-16, 发布年份 2015 | |
PDF
|
|
【 摘 要 】
Purpose
The purpose of the present study was to quantify the inter-fractional motion of the rectum and the rectal and bladder volumes using CBCT scans taken during chemoradiation therapy (CRT) for rectal cancer. Also, assessment was made for a better margin for simultaneous integrated boost - intensity modulated radiation therapy (SIB-IMRT) for rectal cancer.
Methods and materials
There were 32 patients in this study undergoing preoperative CRT for rectal cancer. Each rectum and bladder was contoured on all planning CTs and CBCTs (day 1, 7, 13, 19, 25). The target volume was configured by adding margins (0, 3, 5, 7, 10, and 15 mm) to the rectum on planning CT. The respective percentage of rectal volume that exceeds the target volume was calculated for each of these margins. The percentage of bladder volume that exceeds the bladder volume in the planning CT and motion of the center of gravity of rectum were also analyzed.
Results
Planning CTs and series of each 5 CBCTs for 32 patients were analyzed in this study. The rectal volume tended to shrink week after week. The mean values (± SD) in the 32 series per patient of the percentage of rectum on the CBCTs exceeding target volume in which the margins of 0, 3, 5, 7, 10, and 15 mm were added to the rectum on planning CT were 20.7 ± 12.5%, 7.2 ± 8.3%, 3.9 ± 5.9%, 2.1 ± 3.9%, 0.7 ± 1.8%, and 0.1 ± 0.3%, respectively. No association was seen between the percentage of changes of bladder volume and motion of rectal centroid.
Conclusions
In this study, we estimated the motion of the rectum using planning CT and CBCT. Ten to fifteen mm is a sufficient margin for the rectum during SIB-IMRT for rectal cancer in the supine position.
【 授权许可】
2015 Yamashita et al.; licensee BioMed Central.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20150405163551669.pdf | 2734KB | ||
| Figure 5. | 17KB | Image | |
| Figure 4. | 10KB | Image | |
| Figure 3. | 8KB | Image | |
| Figure 2. | 34KB | Image | |
| Figure 1. | 130KB | Image |
【 图 表 】
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
【 参考文献 】
- [1]Sauer R, Becker H, Hohenberger W, Rödel C, Wittekind C, Fietkau R et al.. Preoperative versus postoperative chemoradiotherapy for rectal cancer. N Engl J Med. 2004; 351:1731-40.
- [2]Roh MS, Colangelo LH, O’Connell MJ, Yothers G, Deutsch M, Allegra CJ et al.. Preoperative multimodality therapy improves disease-free survival in patients with carcinoma of the rectum: NSABP R-03. J Clin Oncol. 2009; 27:5124-30.
- [3]Mok H, Crane CH, Palmer MB, Briere TM, Beddar S, Delclos ME et al.. Intensity modulated radiation therapy (IMRT): differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma. Radiat Oncol. 2011; 6:63. BioMed Central Full Text
- [4]Nijkamp J, Doodeman B, Marijnen C, Vincent A, van Vliet-Vroegindeweij C. Bowel exposure in rectal cancer IMRT using prone, supine, or a belly board. Radiother Oncol. 2012; 102:22-9.
- [5]Vieillot S, Azria D, Lemanski C, Moscardo CL, Gourgou S, Dubois JB et al.. Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer. Radiat Oncol. 2010; 5:92. BioMed Central Full Text
- [6]Richetti A, Fogliata A, Clivio A, Nicolini G, Pesce G, Salati E et al.. Neo-adjuvant chemo-radiation of rectal cancer with volumetric modulated arc therapy: summary of technical and dosimetric features and early clinical experience. Radiat Oncol. 2010; 5:14. BioMed Central Full Text
- [7]Niibe Y, Chang JY. Novel insights of oligometastases and oligo-recurrence and review of the literature. Pulm Med. 2012; 2012:261096.
- [8]Niibe Y, Hayakawa K. Oligometastases and oligo-recurrence: the new era of cancer therapy. Jpn J Clin Oncol. 2010; 40:107-11.
- [9]Seo YS, Kim MS, Yoo HJ, Jang WI. Stereotactic body radiotherapy for oligo-recurrence within the nodal area from colorectal cancer. World J Gastroenterol. 2014; 20:2005-13.
- [10]Chong I, Hawkins M, Hansen V, Thomas K, McNair H, O’Neill B et al.. Quantification of organ motion during chemoradiotherapy of rectal cancer using cone-beam computed tomography. Int J Radiat Oncol Biol Phys. 2011; 81:e431-8.
- [11]Nijkamp J, de Jong R, Sonke JJ, Remeijer P, van Vliet C, Marijnen C. Target volume shape variation during hypo-fractionated preoperative irradiation of rectal cancer patients. Radiother Oncol. 2009; 92:202-9.
- [12]Roeske JC, Forman JD, Mesina CF, He T, Pelizzari CA, Fontenla E et al.. Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. Int J Radiat Oncol Biol Phys. 1995; 33:1321-9.
- [13]Lebesque JV, Bruce AM, Kroes AP, Touw A, Shouman RT, van Herk M. Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer. Int J Radiat Oncol Biol Phys. 1995; 33:1109-19.
- [14]Nuyttens JJ, Robertson JM, Yan D, Martinez A. The variability of the clinical target volume for rectal cancer due to internal organ motion during adjuvant treatment. Int J Radiat Oncol Biol Phys. 2002; 53:497-503.
- [15]Tournel K, De Ridder M, Engels B, Bijdekerke P, Fierens Y, Duchateau M et al.. Assessment of intrafractional movement and internal motion in radiotherapy of rectal cancer using megavoltage computed tomography. Int J Radiat Oncol Biol Phys. 2008; 71:934-9.
PDF