期刊论文详细信息
Radiation Oncology
Which technique for radiation is most beneficial for patients with locally advanced cervical cancer? Intensity modulated proton therapy versus intensity modulated photon treatment, helical tomotherapy and volumetric arc therapy for primary radiation – an intraindividual comparison
Luca Cozzi1  Volker Budach3  Mirko Weihrauch3  Christhardt Koehler2  Oliver Neumann3  Waldemar Wlodarczyk3  Simone Marnitz3 
[1] Radiosurgery and Radiotherapy Department, Istituto Clinico Humanitas Cancer Center and Reaserch Hospital, Rozzano, 20100, Italy;Department of Gynecology, Charité University Medicine, Berlin, Germany;Department of Radiation Oncology, Charité University Hospital, Berlin, Germany
关键词: Proton therapy;    VMAT;    Intensity-modulated radiotherapy;    Cervical cancer;   
Others  :  1177385
DOI  :  10.1186/s13014-015-0402-z
 received in 2015-01-09, accepted in 2015-04-08,  发布年份 2015
PDF
【 摘 要 】

Background

To compare highly sophisticated intensity-modulated radiotherapy (IMRT) delivered by either helical tomotherapy (HT), RapidArc (RA), IMRT with protons (IMPT) in patients with locally advanced cervical cancer.

Methods and materials

Twenty cervical cancer patients were irradiated using either conventional IMRT, VMAT or HT; ten received pelvic (PEL) and ten extended field irradiation (EFRT). The dose to the planning-target volume A (PTV_A: cervix, uterus, pelvic ± para-aortic lymph nodes) was 1.8/50.4 Gy. The SIB dose for the parametrium (PTV_B), was 2.12/59.36 Gy. MRI-guided brachytherapy was administered with 5 fractions up to 25 Gy. For EBRT, the lower target constraints were 95% of the prescribed dose in 95% of the target volume. The irradiated small bowel (SB) volumes were kept as low as possible. For every patient, target parameters as well as doses to the organs at risk (SB, bladder, rectum) were evaluated intra-individually for IMRT, HT, VMAT and IMPT.

Results

All techniques provided excellent target volume coverage, homogeneity, conformity. With IMPT, there was a significant reduction of the mean dose (Dmean) of the SB from 30.2 ± 4.0 Gy (IMRT); 27.6 ± 5.6 Gy (HT); 34.1 ± 7.0 (RA) to 18.6 ± 5.9 Gy (IMPT) for pelvic radiation and 26.3 ± 3.2 Gy (IMRT); 24.0 ± 4.1 (HT); 25.3 ± 3.7 (RA) to 13.8 ± 2.8 Gy (IMPT) for patients with EFRT, which corresponds to a reduction of 38-52% for the Dmean (SB). Futhermore, the low dose bath (V10Gy) to the small bowel was reduced by 50% with IMPT in comparison to all photon techniques. Furthermore, Dmean to the bladder and rectum was decresed by 7-9 Gy with IMPT in patents with pelvic radiation and EFRT.

Conclusion

All modern techniques (were proved to be dosimetrically adequate regarding coverage, conformity and homogeneity of the target. Protons offered the best sparing of small bowel and rectum and therefore could contribute to a significant reduction of acute and late toxicity in cervical cancer treatment.

【 授权许可】

   
2015 Marnitz et al.; licensee BioMed Central.

【 预 览 】
附件列表
Files Size Format View
20150430082032215.pdf 1577KB PDF download
Figure 3. 81KB Image download
Figure 2. 48KB Image download
Figure 1. 45KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

【 参考文献 】
  • [1]Morris M, Eifel PJ, Lu J, Grgsby P, Levenback C, Stevens R et al.. Pelvic radiation with concurrent chemotherapy compared with pelvic and para-aortic radiation for high-risk cervical cancer. N Engl J Med. 1999; 340:1137-43.
  • [2]Vale C, Tierney JF, Stewart LA, Brady M, Dinshaw K, Jakobsen A et al.. Reducing uncertainties about the effects of chemoradiotherapy for cervical cancer: a systematic review and meta-analysis of individual patient data from 18 randomized trials. J Clin Oncol. 2008; 26:5802-12.
  • [3]Green JA, Kirwan JM, Tierney JF, Symonds L, Collingwood M, Williams C. Survival and recurrence after concomitant chemotherapy and radiotherapy for cancer of the uterine cervix: a systematic review and meta-analysis. Lancet. 2001; 358:781-6.
  • [4]Kirwan JM, Symonds P, Green JA, Tierney J, Collingwood M, Williams C. A systematic review of acute and late toxicity of concomitant chemoradiation for cervical cancer. Radiother Oncol. 2003; 68:217-26.
  • [5]Varia MA, Bundy BN, Deppe G, Mannel R, Averette H, Rose P et al.. Cervical carcinoma metastatic to para-aortic nodes: extended field radiation therapy with concomitant 5-fluorouracil and cisplatin chemotherapy: a Gynecologic Oncology Group study. Int J Radiat Oncol Biol Phys. 1998; 42:1015-23.
  • [6]Grigsby PW, Lu JD, Mutch DG, Kim R, Eifel P. Twice-daily fractionation of external irradiation with brachytherapy and chemotherapy in carcinoma of the cervix with positive para-aortic lymph nodes: Phase II study of the Radiation Therapy Oncology Group 92–10. Int J Radiat Oncol Biol Phys. 1998; 41:817-22.
  • [7]Small W, Winter K, Levenback C, Iyer R, Gaffney D, Asbell S et al.. Extended-field irradiation and intracavitary brachytherapy combined with cisplatin chemotherapy for cervical cancer with positive para-aortic or high common iliac lymph nodes: results of ARM 1 of RTOG 0116. Int J Radiat Oncol Biol Phys. 2007; 68:1081-7.
  • [8]Rotman M, Pajak TF, Choi K, Clery M, Marcial V, Grigsby P et al.. Prophylactic extended-field irradiation of para-aortic lymph nodes in stages IIB and bulky IB and IIA cervical carcinomas. Ten-year treatment results of RTOG 79–20. JAMA. 1995; 274:387-93.
  • [9]Portelance L, Chao KS, Grigsby PW, Bennet H, Low D. Intensity-modulated radiation therapy (IMRT) reduces small bowel, rectum, and bladder doses in patients with cervical cancer receiving pelvic and para-aortic irradiation. Int J Radiat Oncol Biol Phys. 2001; 51:261-6.
  • [10]Mundt AJ, Roeske JC, Lujan AE, Yamada S, Waggoner S, Fleming G et al.. Initial clinical experience with intensity-modulated whole-pelvis radiation therapy in women with gynecologic malignancies. Gynecol Oncol. 2001; 82:456-63.
  • [11]Beriwal S, Gan GN, Heron DE, Selvaraj R, Kim H, Lalonde R et al.. Early clinical outcome with concurrent chemotherapy and extended-field, intensity-modulated radiotherapy for cervical cancer. Int J Radiat Oncol Biol Phys. 2007; 68:166-71.
  • [12]Kavanagh BD, Pan CC, Dawson LA, Das S, Li X, Ten Haken R et al.. Radiation dose-volume effects in the stomach and small bowel. Int J Radiat Oncol Biol Phys. 2010; 76:S101-7.
  • [13]Chen MF, Tseng CJ, Tseng CC, Yu C, Wu C, Chen W. Adjuvant concurrent chemoradiotherapy with intensity-modulated pelvic radiotherapy after surgery for high-risk, early stage cervical cancer patients. Cancer J. 2008; 14:200-6.
  • [14]Isohashi F, Yoshioka Y, Mabuchi S, Konishi K, Koizumi M, Takahashi Y et al.. Dose volume histogram predictors of chronic gastrointestinal complications after radical hysterectomy and postoperative concurrent nedaplatin based chemoradiation therapy for early stage cervical cancer. Int J Radiat Oncol Biol Phys. 2013; 85:728-34.
  • [15]Chopra S, Dora T, Chinnachamy A, Thomas B, Kannan S, Engineer R et al.. Predictors of grade 3 or higher late bowel toxicity in patients undergoing pelvic radiation for cervical cancer: results from a prospective study. Int J Radiat Oncol Biol Phys. 2014; 88:630-5.
  • [16]Song WY, Huh SN, Liang Y, White G, Nichols R, Watkins W et al.. Dosimetric comparison study between intensity modulated radiation therapy and three-dimensional conformal proton therapy for pelvic bone marrow sparing in the treatment of cervical cancer. J Appl Clin Med Phys. 2010; 11:3255.
  • [17]van de Water TA, Lomax AJ, Bijl HP, de Jong M, Schilstra C, Hug E et al.. Potential benefits of scanned intensity-modulated proton therapy versus advanced photon therapy with regard to sparing of the salivary glands in oropharyngeal cancer. Int J Radiat Oncol Biol Phys. 2011; 79:1216-24.
  • [18]Weber DC, Wang H, Cozzi L, Dipasquale G, Khan H, Ratib O et al.. RapidArc, intensity modulated photon and proton techniques for recurrent prostate cancer in previously irradiated patients: a treatment planning comparison study. Radiat Oncol. 2009; 4:34. BioMed Central Full Text
  • [19]Zhang X, Li Y, Pan X, Xiaogiang L, Mohan R, Komaki R et al.. Intensity-modulated proton therapy reduces the dose to normal tissue compared with intensity-modulated radiation therapy or passive scattering proton therapy and enables individualized radical radiotherapy for extensive stage IIIB non-small-cell lung cancer: a virtual clinical study. Int J Radiat Oncol Biol Phys. 2010; 77:357-66.
  • [20]Boehling NS, Grosshans DR, Bluett JB, Palmer M, Song X, Amos R et al.. Dosimetric comparison of three-dimensional conformal proton radiotherapy, intensity-modulated proton therapy, and intensity-modulated radiotherapy for treatment of pediatric craniopharyngiomas. Int J Radiat Oncol Biol Phys. 2010; 82:643-52.
  • [21]Georg D, Georg P, Hillbrand M, Poetter R, Mock U. Assessment of improved organ at risk sparing for advanced cervix carcinoma utilizing precision radiotherapy techniques. Strahlenther Onkol. 2008; 184:586-91.
  • [22]Milby AB, Both S, Ingram M, Lin L. Dosimetric comparison of combined intensity-modulated radiotherapy (IMRT) and proton therapy versus IMRT alone for pelvic and para-aortic radiotherapy in gynecologic malignancies. Int J Radiat Oncol Biol Phys. 2010; 82:e477-84.
  • [23]Kagei K, Tokuuye K, Okumura T, Ohara K, Shioyama Y, Sugahara S et al.. Long-term results of proton beam therapy for carcinoma of the uterine cervix. Int J Radiat Oncol Biol Phys. 2003; 55:1265-71.
  • [24]Small W, Mell L, Anderson P, Creutzberg C, De Los Santos J, Gaffney D et al.. Consensus guidelines for delineation of clinical target volume for intensity-modulated pelvic radiotherapy in postoperative treatment of endometrial and cervical cancer. Int J Radiat Oncol Biol Phys. 2008; 71:428-34.
  • [25]Toita T, Ohno T, Kaneyasu Y, Uno T, Yoshimura R et al.. A consensus-based guideline defining the clinical target volume for pelvic lymph nodes in external beam radiotherapy for uterine cervical cancer. Jpn J Clin Oncol. 2010; 40:456-463.
  • [26]Gillin MT, Sahoo N, Bues M, Ciangaru G, Poenisch F, Arjomandy B et al.. Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston. Med Phys. 2010; 37:154-63.
  • [27]Arjomandy B, Sahoo N, Ciangaru G, Zhu R, Song X, Gillin M. Verification of patient-specific dose distributions in proton therapy using a commercial two-dimensional ion chamber array. Med Phys. 2010; 37:5831-7.
  • [28]Feuvret L, Noel G, Mazeron JJ, Bey P. Conformity index: a review. Int J Radiat Oncol Biol Phys. 2006; 64:333-42.
  • [29]Mayo CS, Urie MM. A systematic benchmark method for analysis and comparison of IMRT treatment planning algorithms. Med Dosim. 2003; 28:235-42.
  • [30]Mock U, Bogner J, Georg D, Auberger T, Potter R. Comparative treatment planning on localized prostate carcinoma conformal photon- versus proton-based radiotherapy. Strahlenther Onkol. 2005; 181:448-55.
  • [31]Clivio A, Kluge A, Cozzi L, Koehler C, Neumann O, Vanetti E et al.. Intensity modulated proton beam radiation for brachytherapy in patients with cervical carcinoma. Int J Radiat Oncol Biol Phys. 2013; 87:897-903.
  • [32]Georg P, Poetter R, Georg D, Lang S, Dimopoulos J, Sturdza A et al.. Dose effect relationship for late side effects of the rectum and urinary bladder in magnetic resonance image-guided adaptive cervix cancer brachytherapy. Int J Radiat Oncol Biol Phys. 2010; 82:653-7.
  • [33]Dawson L, Kavanagh B, Paulino A, Shiva D, Miften M, Li A et al.. Radiation associated kidney injury. Int J Radiat Oncol Biol Phys. 2010; 76:S108-15.
  文献评价指标  
  下载次数:0次 浏览次数:7次