Pulsatile lavage irrigator tip, a rare radiolucent retained foreign body in the pelvis: a case report
Michael T Archdeacon1  Camille L Connelly1 
[1] Department of Orthopaedic Surgery, University of Cincinnati, P.O. Box 670212, Cincinnati, OH, 45267-0212, USA
关键词: patient safety;    surgical complication;    pulsatile lavage;    radiolucent;    retained foreign body;   
Others  :  790453
DOI  :  10.1186/1754-9493-5-14
 received in 2011-05-23, accepted in 2011-05-28,  发布年份 2011
PDF
【 摘 要 】

Retained foreign bodies after surgery have the potential to cause serious medical complications for patients and bring fourth serious medico-legal consequences for surgeons and hospitals. Standard operating room protocols have been adopted to reduce the occurrence of the most common retained foreign bodies. Despite these precautions, radiolucent objects and uncounted components/pieces of instruments are at risk to be retained in the surgical wound. We report the unusual case of a retained plastic pulsatile lavage irrigator tip in the surgical wound during acetabulum fracture fixation, which was subsequently identified on routine postoperative computed tomography. Revision surgery was required in order to remove the retained object, and the patient had no further complications.

【 授权许可】

   
2011 Connelly and Archdeacon; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20140705000408621.pdf 3176KB PDF download
Figure 8. 68KB Image download
Figure 7. 114KB Image download
Figure 6. 64KB Image download
acp-11-13305-2011.pdf 7300KB PDF download
Figure 4. 70KB Image download
Figure 3. 21KB Image download
Figure 2. 22KB Image download
Figure 1. 22KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 6.

Figure 7.

Figure 8.

【 参考文献 】
  • [1]Gawande AA, Studdert DM, Orav EJ, Brennan TA, Zinner MJ: Risk factors for retained instruments and sponges after surgery. N Engl J Med 2003, 348(3):229-235.
  • [2]Schonleben K, Strobel A, Schonleben F, Hoffman A: Retained foreign bodies from the surgical point of view. Chirurg 2007, 78:7-12.
  • [3]Stawicki SP, Evans DC, Cipolla J, Seamon MJ, Lukaszczyk JJ, Prosciak MP, Torigian DA, Doraiswamy VA, Yazzie NP, Gunter OL, Steinberg SM: Retained surgical foreign bodies: a comprehensive review of risks and preventive strategies. Scandinavian Journal of Surgery 2009, 98:8-17.
  • [4]Whang G, Mogel GT, Tsai J, Palmer SL: Left behind: unintentionally retained surgically placed foreign bodies and how to reduce their incidence--pictorial review. Am J Roentgenol 2009, 193(Suppl 6):79-89.
  • [5]Letournel E, Judet R: Fractures of the Acetabulum. New York: Springer; 1981.
  • [6]Orthopaedic Trauma Association: Fracture and dislocation classification compendium. J Orthop Trauma 2007, 21(Suppl 10):64-67.
  • [7]Archdeacon MT, Kazemi N, Guy P, Sagi HC: The modified stoppa approach for acetabular fracture. J Am Acad Orthop Surg 2001, 19:170-175.
  • [8]Milstein A: Ending extra payment for "never events"--stronger incentives for patients' safety. N Engl J Med 2009, 360:2388-2390.
  • [9]Rosenthal MB: Nonpayment for performance? medicare's new reimbursement rule. N Engl J Med 2007, 357:1573-1575.
  • [10]Massad M, Slim MS: Intravascular missile embolization in childhood: report of a case, literature review, and recommendations for management. J Pediatr Surg 1990, 25:1292-1294.
  • [11]Goodsett JR, Pahl AC, Glaspy JN, Schapira MM: Kirschner wire embolization to the heart: an unusual cause of pericardial tamponade. Chest 1999, 115:291-293.
  • [12]Freund E, Nachman R, Gips H, Hiss J: Migration of a Kirschner wire used in the fixation of a subcapital humeral fracture, causing cardiac tamponade: case report and review of literature. Am J Forensic Med Pathol 2007, 28:155-156.
  文献评价指标  
  下载次数:63次 浏览次数:18次