期刊论文详细信息
Radiation Oncology
Incorporating breath holding and image guidance in the adjuvant gastric cancer radiotherapy: a dosimetric study
Zhen Zhang1  Qing Xu1  Jiazhou Wang1  Jinsong Ye2  Weigang Hu1 
[1] Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Department of Oncology, Shanghai Medical College, Fudan University, Shanghai, China, 200032;Department of Radiation Oncology, Swedish Caner Institute, Seattle, WA, USA
关键词: Dose convolution;    Image-guided radiotherapy;    Breath holding;    Intensity-modulated radiotherapy;    Gastric cancer;   
Others  :  1160818
DOI  :  10.1186/1748-717X-7-98
 received in 2012-01-09, accepted in 2012-06-20,  发布年份 2012
PDF
【 摘 要 】

Background

The respiratory related target motion and setup error will lead to a large margin in the gastric radiotherapy. The purpose of this study is to investigate the dosimetric benefit and the possibility of incorporating the breath-hold (BH) technique with online image-guided radiotherapy in the adjuvant gastric cancer radiotherapy.

Methods

Setup errors and target motions of 22 post-operative gastric cancer patients with surgical clips were analyzed. Clips movement was recorded using the digital fluoroscopics and the probability distribution functions (pdf) of the target motions were created for both the free breathing (FB) and BH treatment. For dosimetric comparisons, two intensity-modulated radiotherapy (IMRT) treatment plans, i.e. the free breathing treatment plan (IMRTFB) and the image-guided BH treatment plan (IMRTIGBH) using the same beam parameters were performed among 6 randomly selected patients. Different margins for FB and BH plans were derived. The plan dose map was convoluted with various pdfs of the setup errors and the target motions. Target coverage and dose to organs at risk were compared and the dose-escalation probability was assessed.

Results

The mean setup errors were 1.2 mm in the superior-inferior (SI), 0.0 mm in the left-right (LR), and 1.4 mm in the anterior-posterior (AP) directions. The mean target motion for the free breathing (vs. BH) was 11.1 mm (vs. 2.2 mm), 1.9 mm (vs. 1.1 mm), and 5.5 mm (vs. 1.7 mm) in the SI, LR, and AP direction, respectively. The target coverage was comparable for all the original plans. IMRTIGBH showed lower dose to the liver compared with IMRTFB (p = 0.01) but no significant difference in the kidneys. Convolved IMRTIGBH showed better sparing in kidneys (p < 0.01) and similar in liver (p = 0.08).

Conclusions

Combining BH technique with online image guided IMRT can minimize the organ motion and improve the setup accuracy. The dosimetric comparison showed the dose could be escalated to 54 Gy without increasing the critical organs toxicities, although further clinical data is needed.

【 授权许可】

   
2012 Hu et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150411081059866.pdf 1094KB PDF download
Figure 3 . 117KB Image download
Figure 2 . 45KB Image download
Figure 1 . 69KB Image download
【 图 表 】

Figure 1 .

Figure 2 .

Figure 3 .

【 参考文献 】
  • [1]Moertel CG, Childs DS, Reitemeier RJ, Colby MY, Holbrook MA: Combined 5-fluorouracil and supervoltage radiation therapy of locally unresectable gastrointestinal cancer. Lancet 1969, 2:865-867.
  • [2]Macdonald JS, Benedetti J, Smalley S: Chemoradiation of resected gastric cancer: a 10-year follow-up of the phase III trial INT0116 (SWOG9008)[abstract]. J Clin Oncol 2009, 27:4515.
  • [3]Bockbrader M, Kim E: Role of intensity-modulated radiation therapy in gastrointestinal cancer. Expert Rev Anticancer Ther 2009, 9:637-647.
  • [4]Minn AY, Hsu A, La T, Kunz P, Fisher GA, Ford JM, Norton JA, Visser B, Goodman KA, Koong AC, Chang DT: Comparison of intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy as adjuvant therapy for gastric cancer. Cancer 2010, 116:3943-3952.
  • [5]Dickie CI, Parent AL, Chung PW, Catton CN, Craig T, Griffin AM, Panzarella T, Ferguson PC, Wunder JS, Bell RS, Sharpe MB, O'Sullivan B: Measuring interfractional and intrafractional motion with cone beam computed tomography and an optical localization system for lower extremity soft tissue sarcoma patients treated with preoperative intensity-modulated radiation therapy. Int J Radiat Oncol Biol Phys 2010, 78:1437-1444.
  • [6]Brandner ED, Wu A, Chen H, Heron D, Kalnicki S, Komanduri K, Gerszten K, Burton S, Ahmed I, Shou Z: Abdominal organ motion measured using 4D CT. Int J Radiat Oncol Biol Phys 2006, 65:554-560.
  • [7]Katoh N, Onimaru R, Sakuhara Y, Abo D, Shimizu S, Taguchi H, Watanabe Y, Shinohara N, Ishikawa M, Shirato H: Real-time tumor-tracking radiotherapy for adrenal tumors. Radiother Oncol 2008, 87:418-424.
  • [8]Wong JW, Sharpe MB, Jaffray DA, Kini VR, Robertson JM, Stromberg JS, Martinez AA: The use of active breathing control (ABC) to reduce margin for breathing motion. Int J Radiat Oncol Biol Phys 1999, 44:911-919.
  • [9]Kubo HD, Hill BC: Respiration gated radiotherapy treatment: a technical study. Phys Med Biol 1996, 41:83-91.
  • [10]Lujan AE, Balter JM, Ten Haken RK: A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion. Med Phys 2003, 30:2643-2649.
  • [11]Rosu M, Dawson LA, Balter JM, McShan DL, Lawrence TS, Ten Haken RK: Alterations in normal liver doses due to organ motion. Int J Radiat Oncol Biol Phys 2003, 57:1472-1479.
  • [12]van Herk M, Remeijer P, Rasch C, Lebesque JV: The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys 2000, 47:1121-1135.
  • [13]Henning GT, Schild SE, Stafford SL, Donohue JH, Burch PA, Haddock MG, Trastek VF, Gunderson LL: Results of irradiation or chemoirradiation following resection of gastric adenocarcinoma. Int J Radiat Oncol Biol Phys 2000, 46:589-598.
  • [14]Soyfer V, Corn BW, Melamud A, Alani S, Tempelhof H, Agai R, Shmueli A, Figer A, Kover F: Three-dimensional non-coplanar conformal radiotherapy yields better results than traditional beam arrangements for adjuvant treatment of gastric cancer. Int J Radiat Oncol Biol Phys 2007, 69:364-369.
  • [15]Pouliot J, Bani-Hashemi A, Chen J, Svatos M, Ghelmansarai F, Mitschke M, Aubin M, Xia P, Morin O, Bucci K, Roach M, Hernandez P, Zheng Z, Hristov D, Verhey L: Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 2005, 61:552-560.
  • [16]Kimura T, Hirokawa Y, Murakami Y, et al.: Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy. Int J Radiat Oncol Biol Phys 2004, 60:1307-1313.
  • [17]Rudat V, Flentje M, Oetzel D, et al.: Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapy. Radiother Oncol 1994, 33:56-63.
  文献评价指标  
  下载次数:23次 浏览次数:2次