期刊论文详细信息
World Journal of Surgical Oncology
Clinical application of ultrasound-guided core needle biopsy with multiple punches in the diagnosis of lymphoma
Qin Zhang3  Xudong Chen5  Xiaohong Xu1  Bosheng He2  Yanggui Xie4  Xiuzhen Ji3  Ying He3 
[1] Department of Oncology, The Cancer Hospital of Nantong University, No. 30 Tongyang North Road, Pingchao Town, Tongzhou District, Nantong 226361, China;Department of Radiology, The Second Affiliated Hospital of Nantong University, No.6 Hai Er Xiang North Road, Nantong 226001, Jiangsu, P.R. China;Department of Ultrasound, The Cancer Hospital of Nantong University, No. 30 Tongyang North Road, Pingchao Town, Tongzhou District, Nantong 226361, China;Department of Ultrasound, The First Affiliated Hospital of Nantong University, No. 20 Xisi Road, Nantong 226001, China;Department of Pathology, The Cancer Hospital of Nantong University, No. 30 Tongyang North Road, Pingchao Town, Tongzhou District, Nantong 226361, China
关键词: Accuracy rate;    Multiple punches;    Core needle biopsy;    Ultrasound-guided;    Lymphoma;   
Others  :  1145993
DOI  :  10.1186/s12957-015-0537-2
 received in 2014-12-19, accepted in 2015-03-07,  发布年份 2015
PDF
【 摘 要 】

Background

The purpose of this study is to investigate the feasibility, accuracy, and limitations of ultrasound (US)-guided core needle biopsy (CNB) with multiple punches in the diagnosis of lymphoma in the whole body.

Methods

From March 2007 to October 2013, US-guided CNB with multiple punches was performed by well-experienced radiologists in 110 patients (CNB group), and surgical biopsy was carried out in 95 patients (surgical group). The differences of accuracy rate between the two groups in the diagnosis of lymphoma and its subtypes were examined with Fisher’s exact test.

Results

There were no statistical differences between the CNB group and the surgical group in the diagnostic accuracy rate of lymphoma, as well as its subtypes in superficial and deep masses. In addition, in the CNB group, there were no statistical differences between different lengths of lesions in the diagnosis accuracy rate of lymphoma and its subtypes.

Conclusions

US-guided CNB with no less than three punches is an accurate, safe, minimally invasive, non-radiological, fast, and cost-effective method in the evaluation of lymphoma and its subtypes as compared with surgical approach. It should be considered as the acceptable alternative to surgical biopsy to obtain histopathological samples in the patients with suspected lymphoma.

【 授权许可】

   
2015 He et al.; licensee BioMed Central.

【 预 览 】
附件列表
Files Size Format View
20150403082956582.pdf 1678KB PDF download
Figure 3. 39KB Image download
Figure 2. 17KB Image download
Figure 1. 47KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

【 参考文献 】
  • [1]Halliday T, Baxter G. Lymphoma: pictorial review. I. Eur Radiol. 2003; 13:1154-64.
  • [2]Skoog L, Tani E. Diagnosis of lymphoma by fine-needle aspiration cytology using the revised European-American classification of lymphoid neoplasms. Cancer. 2000; 90:320-3.
  • [3]Lachar WA, Shahab I, Saad AJ. Accuracy and cost-effectiveness of core needle biopsy in the evaluation of suspected lymphoma: a study of 101 cases. Arch Pathol Lab Med. 2007; 131:1033-9.
  • [4]de Kerviler E, de Bazelaire C, Mounier N, Mathieu O, Brethon B, Briere J et al.. Image-guided core-needle biopsy of peripheral lymph nodes allows the diagnosis of lymphomas. Eur Radiol. 2007; 17:843-9.
  • [5]Demharter J, Neukirchen S, Wagner T, Schlimok G, Bohndorf K, Kirchhof K. Do ultrasound-guided core needle biopsies of lymph nodes allow for subclassification of malignant lymphomas? Rofo. 2007; 179:396-400.
  • [6]Li L, Wu QL, Liu LZ, Mo YX, Xie CM, Zheng L et al.. Value of CT-guided core-needle biopsy in diagnosis and classification of malignant lymphomas using automated biopsy gun. World J Gastroenterol. 2005; 11:4843-7.
  • [7]Kim BM, Kim EK, Kim MJ, Yang WI, Park CS, Park SI. Sonographically guided core needle biopsy of cervical lymphadenopathy in patients without known malignancy. J Ultrasound Med. 2007; 26:585-91.
  • [8]Zinzani PL, Corneli G, Cancellieri A, Magagnoli M, Lacava N, Gherlinzoni F et al.. Core needle biopsy is effective in the initial diagnosis of mediastinal lymphoma. Haematologica. 1999; 84:600-3.
  • [9]Ben-Yehuda D, Polliack A, Okon E, Sherman Y, Fields S, Lebenshart P et al.. Image-guided core-needle biopsy in malignant lymphoma: experience with 100 patients that suggests the technique is reliable. J Clin Oncol. 1996; 14:2431-4.
  • [10]Pappa VI, Hussain HK, Reznek RH, Whelan J, Norton AJ, Wilson AM et al.. Role of image-guided core-needle biopsy in the management of patients with lymphoma. J Clin Oncol. 1996; 14:2427-30.
  • [11]de Larrinoa AF, del Cura J, Zabala R, Fuertes E, Bilbao F, Lopez JI. Value of ultrasound-guided core biopsy in the diagnosis of malignant lymphoma. J Clin Ultrasound. 2007; 35:295-301.
  • [12]Walsh S, Lowery AJ, Evoy D, McDermott EW, Prichard RS. Thyroid lymphoma: recent advances in diagnosis and optimal management strategies. Oncologist. 2013; 18:994-1003.
  • [13]Stewart CJ, Coldewey J, Stewart IS. Comparison of fine needle aspiration cytology and needle core biopsy in the diagnosis of radiologically detected abdominal lesions. J Clin Pathol. 2002; 55:93-7.
  • [14]Screaton NJ, Berman LH, Grant JW. Head and neck lymphadenopathy: evaluation with US-guided cutting-needle biopsy. Radiology. 2002; 224:75-81.
  • [15]Janes SE, Lengyel JA, Singh S, Aluwihare N, Isgar B. Needle core biopsy for the assessment of unilateral breast masses in men. Breast. 2006; 15:273-5.
  • [16]Zinzani PL, Colecchia A, Festi D, Magagnoli M, Larocca A, Ascani S et al.. Ultrasound-guided core-needle biopsy is effective in the initial diagnosis of lymphoma patients. Haematologica. 1998; 83:989-92.
  • [17]Huang PC, Liu CY, Chuang WY, Shih LY, Wan YL. Ultrasound-guided core needle biopsy of cervical lymphadenopathy in patients with lymphoma: the clinical efficacy and factors associated with unsuccessful diagnosis. Ultrasound Med Biol. 2010; 36:1431-6.
  • [18]Britton PD, Provenzano E, Barter S, Gaskarth M, Goud A, Moyle P et al.. Ultrasound guided percutaneous axillary lymph node core biopsy: how often is the sentinel lymph node being biopsied? Breast. 2009; 18:13-6.
  • [19]Sklair-Levy M, Amir G, Spectre G, Lebensart P, Applbaum Y, Agid R et al.. Image-guided cutting-edge-needle biopsy of peripheral lymph nodes and superficial masses for the diagnosis of lymphoma. J Comput Assist Tomogr. 2005; 29:369-72.
  • [20]Sabattini E, Bisgaard K, Ascani S, Poggi S, Piccioli M, Ceccarelli C et al.. The EnVision++ system: a new immunohistochemical method for diagnostics and research. Critical comparison with the APAAP, ChemMate, CSA, LABC, and SABC techniques. J Clin Pathol. 1998; 51:506-11.
  • [21]Ganott MA, Zuley ML, Abrams GS, Lu AH, Kelly AE, Sumkin JH et al.. Ultrasound guided core biopsy versus fine needle aspiration for evaluation of axillary lymphadenopathy in patients with breast cancer. ISRN Oncol. 2014; 2014:703160.
  • [22]Hehn ST, Grogan TM, Miller TP. Utility of fine-needle aspiration as a diagnostic technique in lymphoma. J Clin Oncol. 2004; 22:3046-52.
  • [23]Sklair-Levy M, Polliack A, Shaham D, Applbaum YH, Gillis S, Ben-Yehuda D et al.. CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma. Eur Radiol. 2000; 10:714-8.
  • [24]de Kerviler E, Guermazi A, Zagdanski AM, Meignin V, Gossot D, Oksenhendler E et al.. Image-guided core-needle biopsy in patients with suspected or recurrent lymphomas. Cancer. 2000; 89:647-52.
  • [25]Demharter J, Muller P, Wagner T, Schlimok G, Haude K, Bohndorf K. Percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas. Eur Radiol. 2001; 11:276-83.
  • [26]Youk JH, Kim EK, Kwak JY, Son EJ. Atypical papilloma diagnosed by sonographically guided 14-gauge core needle biopsy of breast mass. AJR Am J Roentgenol. 2010; 194:1397-402.
  • [27]Bahn YE, Lee SK, Kwon SY, Kim SP. Sonographic appearances of mucosa-associated lymphoid tissue lymphoma of the submandibular gland confirmed with sonographically guided core needle biopsy. J Clin Ultrasound. 2011; 39:228-32.
  • [28]Schueller G, Jaromi S, Ponhold L, Fuchsjaeger M, Memarsadeghi M, Rudas M et al.. US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases. Radiology. 2008; 248:406-13.
  • [29]Abe H, Schmidt RA, Kulkarni K, Sennett CA, Mueller JS, Newstead GM. Axillary lymph nodes suspicious for breast cancer metastasis: sampling with US-guided 14-gauge core-needle biopsy–clinical experience in 100 patients. Radiology. 2009; 250:41-9.
  • [30]de Kerviler E, Benet C, Briere J, de Bazelaire C. Image-guided needle biopsy for diagnosis and molecular biology in lymphomas. Best Pract Res Clin Haematol. 2012; 25:29-39.
  • [31]Bolivar AV, Alonso-Bartolome P, Garcia EO, Ayensa FG. Ultrasound-guided core needle biopsy of non-palpable breast lesions: a prospective analysis in 204 cases. Acta Radiol. 2005; 46:690-5.
  文献评价指标  
  下载次数:191次 浏览次数:34次