期刊论文详细信息
Radiation Oncology
Feasibility of constant dose rate VMAT in the treatment of nasopharyngeal cancer patients
Xiance Jin1  Yongqiang Zhou1  Jinling Yi1  Ce Han1  Congying Xie1  Haijiao Shang2  Wenliang Yu3 
[1]Department of Radiotherapy and Chemotherapy, the 1st Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China
[2]Research department of IPTA(Beijing) Investment Administration Co., Ltd, Beijing, China
[3]Radiation Oncology Department, Quzhou People¿s Hospital, No. 2 Zhongloudi Street, Quzhou 324000, China
关键词: Nasopharyngeal cancer;    Multicriteria optimization;    Variable dose rate;    Constant dose rate;    Volumetric-modulated arc therapy;   
Others  :  1151016
DOI  :  10.1186/s13014-014-0235-1
 received in 2014-07-16, accepted in 2014-10-12,  发布年份 2014
PDF
【 摘 要 】

Purpose

To investigate the feasibility of constant dose rate volumetric modulated arc therapy (CDR-VMAT) in the treatment of nasopharyngeal cancer (NPC) patients and to introduce rotational arc radiotherapy for linacs incapable of dose rate variation.

Materials and methods

Twelve NPC patients with various stages treated previously using variable dose rate (VDR) VMAT were enrolled in this study. CDR-VMAT, VDR-VMAT and mutlicriteria optimization (MCO) VMAT plans were generated for each patient on RayStation treatment planning system with identical objective functions and the dosimetric differences among these three planning schemes were evaluated and compared. Non dosimetric parameters of optimization time, delivery time and delivery accuracy were also evaluated.

Results

The planning target volume of clinical target volume (PTV-CTV) coverage of CDR-VMAT was a bit inferior to those of VDR- and MCO-VMAT. The V93 (p?=?0.01) and V95 (percent volume covered by isodose line) (p?=?0.04) for CDR-VMAT, VDR-VMAT and MCO-VMAT were 98.74%?±?0.31%, 99.76%?±?0.16%, 99.38%?±?0.43%, and 98.40%?±?0.48%, 99.53%?±?0.28%, 99.07%?±?0.52%, respectively. However, the CDR-VMAT showed a better dose homogeneity index (HI) (p?=?0.01) in PTV-CTV. No significant difference in other target coverage parameters was observed. There was no significant difference in OAR sparing among these three planning schemes except for a higher maximum dose (Dmax) on the brainstem for CDR-VMAT. The brainstem Dmax of CDR-VMAT, VDR-VMAT and MCO-VMAT were 54.26?±?3.21 Gy, 52.19?±?1.65 Gy, and 52.79?±?4.77 Gy, respectively. The average delivery time (p?

Conclusion

CDR-VMAT offers an additional option of rotational arc radiotherapy for linacs incapable of dose rate variation with a lower initial cost. Its plan quality was acceptable but should be thoroughly checked compared with VDR-VMAT and MCO-VMAT in the treatment of NPC.

【 授权许可】

   
2014 Yu et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150406013414752.pdf 2418KB PDF download
Figure 2. 69KB Image download
Figure 1. 83KB Image download
【 图 表 】

Figure 1.

Figure 2.

【 参考文献 】
  • [1]Pirzkall A, Carol M, Lohr F, Höss A, Wannenmacher M, Debus J: Comparison of intensity modulated radiotherapy with conventional conformal radiotherapy for complex-shaped tumors. Int J Radiat Oncol Biol Phys 2000, 48:1371-1380.
  • [2]Lee N, Kramer A, Xia P: A Phase II Study of Intensity Modulated Radiation Therapy (IMRT) t/_ Chemotherapy for Nasopharyngeal Cancer. Radiation Therapy Oncology Group, Philadelphia, PA; 2003.
  • [3]Ruben JD, Lancaster CM, Jones P, Smith RL: A comparison of out-of-field dose and its constituent components for intensity-modulated radiation therapy versus conformal radiation therapy: implications for carcinogenesis. Int J Radiat Oncol Biol Phys 2011, 81:1458-1464.
  • [4]Otto K: Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 2008, 35:310-317.
  • [5]Palma D, Vollans E, James K, Nakano S, Moiseenko V, Shaffer R, McKenzie M, Morris J, Otto K: Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy. Int J Radiat Oncol Biol Phys 2008, 72:996-1001.
  • [6]Jin X, Yi J, Zhou Y, Yan H, Han C, Xie C: Comparing of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer. Med Dosim 2013, 38:418-423.
  • [7]McGarry CK, McMahon SJ, Craft D, O¿Sullivan JM, Prise KM, Hounsell AR: Inverse planned constant dose rate volumetric modulated arc therapy (VMAT) as an efficient alternative to five-field intensity modulated radiation therapy (IMRT) for prostate. J Radiother Pract 2014, 13:68-78.
  • [8]Ottosson RO, Engstrom PE, Sjöström D, Behrens CF, Karlsson A, Knöös T, Ceberg C: The feasibility of using Pareto fronts for comparison of treatment planning systems and delivery techniques. Acta Oncol 2009, 48:233-237.
  • [9]Petersson K, Ceberg C, Engstrom P, Benedek H, Nilsson P, Knoos T: Conversion of helical tomotherapy plans to step-and-shoot IMRT plans¿Pareto front evaluation of plans from a new treatment planning system. Med Phys 2011, 38(6):3130-3138.
  • [10]Craft D, Halabi T, Bortfeld T: Exploration of tradeoffs in intensity-modulated radiotherapy. Phys Med Biol 2005, 50:5857-5868.
  • [11]Bokrantz R: Multicriterial optimization for volumetric-modulated arc therapy by decomposition into a fluence-based relaxation and a segment weight-based restriction. Med Phys 2012, 39:6712-6725.
  • [12]Wu S, Xie C, Jin X, Zhang P: Simultaneous modulated accelerated radiation therapy in the treatment of nasopharyngeal cancer: a local center¿s experience. Int J Radiat Oncol Biol Phys 2006, 66:S40-S46.
  • [13]Iori M, Cattaneo GM, Cagni E, Fiorino C, Borasi G, Riccardo C, Iotti C, Fazio F, Nahum AE: Dose-volume and biological-model based comparison between helical tomotherapy and (inverse-planned) IMAT for prostate tumours. Radiother Oncol 2008, 88:34-45.
  • [14]Lomax NJ, Scheib SG: Quantifying the degree of conformity in radiosurgery treatment planning. Int J Radiat Oncol Biol Phys 2003, 55:1409-1419.
  • [15]van¿t Riet A, Mak AC, Moerland MA, Elders LH, van der Zee W: A conformation number to quantify the degree of conformity in brachytherapy and external beam irradiation: application to the prostate. Int J Radiat Oncol Biol Phys 1997, 37:731-736.
  • [16]Hatanaka S, Tamaki S, Endo H, Mizuno N, Nakamura N: Utility of Smart Arc CDR for intensity-modulated radiation therapy for prostate cancer.J Radiation Res 2014, pp 1¿6, doi: 10.1093/jrr/rrt232.
  • [17]Tang G, Earl MA, Yu CX: Variable dose rate single-arc IMAT delivered with a cosntant dose rate and variable angular spacing. Phys Med Biol 2009, 54:6439-6456.
  • [18]Popescu CC, Olivotto IA, Beckham WA, Ansbacher W, Zavgorodni S, Shaffer R, Wai ES, Otto K: Volumetric modulatedarc therapy improves dosimetry and reduces treatment time compared to conventional intensity-modulated radiotherapy for locoregional radiotherapy of left- sided breast cancer and internal mammary nodes. Int J Radiat Oncol Biol Phys 2010, 76:287-295.
  文献评价指标  
  下载次数:15次 浏览次数:15次