| Radiation Oncology | |
| Evaluation of inter-observer variability of bladder boundary delineation on cone-beam CT | |
| Hiroki Shirato1  Rikiya Onimaru1  Yukiko Nishikawa1  Keiichi Harada1  Koichi Yasuda1  Shunsuke Onodera1  Tetsuya Inoue1  Rumiko Kinoshita1  Shinichi Shimizu1  Kentaro Nishioka1  | |
| [1] Department of Radiation Medicine, Hokkaido University School of Medicine, Sapporo, Japan | |
| 关键词: Inter-observer variability; Cone beam CT; Image guided radiotherapy; Bladder cancer; | |
| Others : 1153329 DOI : 10.1186/1748-717X-8-185 |
|
| received in 2013-04-24, accepted in 2013-07-21, 发布年份 2013 | |
PDF
|
|
【 摘 要 】
Background
In-room cone-beam computerized tomography (CBCT) imaging is a promising method to reduce setup errors, especially in organs such as the bladder that often have large intrafractional variations due to organ movement. CBCT image quality is limited by low contrast and imaging artifacts, but few data have been reported about inter-observer variability of bladder boundary delineation on CBCT. The aim of this work was to analyze and evaluate the inter-observer contouring uncertainties of bladder boundary delineation on CBCT images in a prospective fashion.
Methods
Five radiation oncologists contoured 10 bladders using the CBCT datasets of consecutive 10 patients (including 4 females) who were irradiated to the pelvic region. Prostates were also contoured in male patients. Patients who had had prostatectomy were excluded. The coefficient of variation (COV), conformity index (CIgen), and coordinates of center-of-mass (COM) of the bladder and prostate were calculated for each patient.
Results
The mean COV for the bladder and prostate was 0.08 and 0.20, respectively. The mean CIgen of the bladder and prostate was 0.81 and 0.66, respectively. The root mean square (RMS) of the inter-observer standard deviation (σ) of the COM displacement in the left-right (LR) and anterior-posterior (AP) direction was 0.79, 0.87 and 0.54 for the bladder and 0.63, 0.99 and 1.72 for the prostate. Regarding the mean COV and CIgen for the bladder, the differences between males and females were not significant.
Conclusions
Inter-observer variability for bladder delineation on CBCT images was substantially small regardless of gender. We believe that our results support the applicability of CBCT in adaptive radiotherapy for bladder cancer.
【 授权许可】
2013 Nishioka et al.; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20150407075702596.pdf | 723KB | ||
| Figure 3. | 80KB | Image | |
| Figure 2. | 39KB | Image | |
| Figure 1. | 102KB | Image |
【 图 表 】
Figure 1.
Figure 2.
Figure 3.
【 参考文献 】
- [1]Turner SL, Swindell R, Bowl N, Marrs J, Brookes B, Read G, Cowan RA: Bladder movement during radiation therapy for bladder cancer: implications for treatment planning. Int J Radiat Oncol Biol Phys 1997, 39:355-360.
- [2]Harris SJ, Buchanan RB: An audit and evaluation of bladder movements during radical radiotherapy. Clin Oncol 1998, 10:262-264.
- [3]Zietman A, Skinner E: Quality of life after radical treatment for invasive bladder cancer. Semin Radiat Oncol 2005, 15:55-59.
- [4]Efstathiou J a, Bae K, Shipley WU, Kaufman DS, Hagan MP, Heney NM, Sandler HM: Late pelvic toxicity after bladder-sparing therapy in patients with invasive bladder cancer: RTOG 89–03, 95–06, 97–06, 99–06. J Clin Oncol: official J Am Soc of Clin Oncol 2009, 27:4055-4061.
- [5]Thariat J, Aluwini S, Pan Q, Caullery M, Marcy P-Y, Housset M, Lagrange J-L: Image-guided radiation therapy for muscle-invasive bladder cancer. Nat Rev Urol 2012, 9:23-29.
- [6]Pos F, Remeijer P: Adaptive management of bladder cancer radiotherapy. Semin Radiat Oncol 2010, 20:116-120.
- [7]Shirato H, Shimizu S, Kitamura K, Nishioka T, Kagei K, Hashimoto S, Aoyama H, Kunieda T, Shinohara N, Dosaka-Akita H, Miyasaka K: Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys 2000, 48:435-442.
- [8]Shimizu S, Shirato H, Kitamura K, Shinohara N, Harabayashi T, Tsukamoto T, Koyanagi T, Miyasaka K: Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. Int J Radiat Oncol Biol Phys 2000, 48:1591-1597.
- [9]Tuomikoski L, Collan J, Keyriläinen J, Visapää H, Saarilahti K, Tenhunen M: Adaptive radiotherapy in muscle invasive urinary bladder cancer–an effective method to reduce the irradiated bowel volume. Radio Oncol: J Eur Society for Therapeutic Rad Oncol 2011, 99:61-66.
- [10]Lalondrelle S, Huddart R, Warren-Oseni K, Hansen VN, McNair H, Thomas K, Dearnaley D, Horwich A, Khoo V: Adaptive-predictive organ localization using cone-beam computed tomography for improved accuracy in external beam radiotherapy for bladder cancer. Int J Radiat Oncol Biol Phys 2011, 79:705-712.
- [11]Murthy V, Master Z, Adurkar P, Mallick I, Mahantshetty U, Bakshi G, Tongaonkar H, Shrivastava S: “Plan of the day” adaptive radiotherapy for bladder cancer using helical tomotherapy. Rad oncol: J Eur Soc for Therapeutic Rad Oncol 2011, 99:55-60.
- [12]Foroudi F, Wong J, Kron T, Rolfo A, Haworth A, Roxby P, Thomas J, Herschtal A, Pham D, Williams S, Tai KH, Duchesne G: Online adaptive radiotherapy for muscle-invasive bladder cancer: Results of a pilot study. Int J Radiat Oncol Biol Phys 2011, 81:765-771.
- [13]Button MR, Staffurth JN: Clinical application of image-guided radiotherapy in bladder and prostate cancer. Clin Oncol 2010, 22:698-706.
- [14]Lütgendorf-Caucig C, Fotina I, Stock M, Pötter R, Goldner G, Georg D: Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study. Rad Oncol: J Eur Society for Therapeutic Rad Oncol 2011, 98:154-161.
- [15]Weiss E, Wu J, Sleeman W, Bryant J, Mitra P, Myers M, Ivanova T, Mukhopadhyay N, Ramakrishnan V, Murphy M, Williamson J: Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging. Int J Radiat Oncol Biol Phys 2010, 78:929-936.
- [16]Logue J, Sharrock C, Cowan R: Clinical variability of target volume description in conformal radiotherapy planning. Int J Radiat Oncol Biol Phys 1998, 41:929-931.
- [17]Meijer G, Rasch C, Remeijer P, Lebesque J: Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer. Int J Radiat Oncol Biol Phys 2003, 55:1277-1287.
- [18]Kouwenhoven E, Giezen M, Struikmans H: Measuring the similarity of target volume delineations independent of the number of observers. Phys Med Biol 2009, 54:2863-2873.
- [19]Fotina I, Lütgendorf-Caucig C, Stock M, Pötter R, Georg D: Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy. Strahlentherapie und Onkologie: Organ der Deutschen Röntgengesellschaft…[et al.] 2012, 188:160-167.
- [20]Boda-Heggemann J, Lohr F, Wenz F, Flentje M, Guckenberger M: kV cone-beam CT-based IGRT: a clinical review. Strahlentherapie und Onkologie: Organ der Deutschen Röntgengesellschaft…[et al.] 2011, 187:284-291.
- [21]Palombarini M, Mengoli S, Fantazzini P, Cadioli C, Degli Esposti C, Frezza GP: Analysis of inter-fraction setup errors and organ motion by daily kilovoltage cone beam computed tomography in intensity modulated radiotherapy of prostate cancer. Radiat Oncol (London, England) 2012, 7:56. BioMed Central Full Text
- [22]Moseley DJ, White E a, Wiltshire KL, Rosewall T, Sharpe MB, Siewerdsen JH, Bissonnette J-P, Gospodarowicz M, Warde P, Catton CN, Jaffray D a: Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate. Int J Radiat Oncol Biol Phys 2007, 67:942-953.
- [23]Barney BM, Lee RJ, Handrahan D, Welsh KT, Cook JT, Sause WT: Image-guided radiotherapy (IGRT) for prostate cancer comparing kV imaging of fiducial markers with cone beam computed tomography (CBCT). Int J Radiat Oncol Biol Phys 2011, 80:301-305.
- [24]Foroudi F, Haworth a, Pangehel a, Wong J, Roxby P, Duchesne G, Williams S, Tai KH: Inter-observer variability of clinical target volume delineation for bladder cancer using CT and cone beam CT. J Med Imaging Radiat Oncol 2009, 53:100-106.
- [25]White E a, Brock KK, Jaffray D a, Catton CN: Inter-observer variability of prostate delineation on cone beam computerised tomography images. Clinical oncology (Royal College of Radiologists (Great Britain)) 2009, 21:32-38.
PDF