Head & Face Medicine
Facial landmark localization by curvature maps and profile analysis
Gholamreza Danesh1  Tatjana Moiseenko5  Christian Kirschneck6  Kristina Schreiber1  Burkhard Drerup4  Kim Wangdo3  Xiang Liu2  Carsten Lippold5 
[1] Department of Orthodontics, Dental Clinic of Witten Herdecke, Alfred-Herrhausen-Straße 50, 58448 Witten, Germany;MOM, MAE, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore;Fac Motricidade Humana, CIPER, LBMF, SPERTLAB, Univ Tecn Lisboa, Estrada da Costa, P-1499-002, Lisbon, Portugal;Bundesfachschule f. Orthopaedietechnik (BUFA), Schliepstraße 6, 44135 Dortmund, Germany;Department of Orthodontics, University Medical Centre of Muenster, Waldeyerstraße 30, 48149 Münster, Germany;Department of Orthodontics, University Medical Center Regensburg, Franz-Josef-Strauß-Allee 11, 93053 Regensburg, Germany
关键词: Lasers/diagnostic use;    Computer-assisted three-dimensional imaging;    Reproducibility of results;    Image interpretation;    Biological;    Models;    Lasers;    Feasibility studies;    Orthodontics;   
Others  :  1135960
DOI  :  10.1186/1746-160X-10-54
 received in 2014-10-28, accepted in 2014-11-28,  发布年份 2014
PDF
【 摘 要 】

Introduction

Three-dimensional landmarks of the face are important for orthodontic examination, harmony assessment and treatment planning. Currently, facial landmarks are often measured by orthodontists via direct observation and manual soft tissue image analysis. This study wants to evaluate and present an objective method for measuring selected facial landmarks based on an analysis of curvature maps and of sagittal profile obtained by a laser-scanning method.

Methods

The faces of 15 people were scanned in 3D by means of the laser scanner FastSCAN™. It allowed the recording of a curvature map of the face in under a minute, which depicted the distribution of Gaussian and mean curvatures. The median-sagittal profile line of the face was localized in this map, and a mathematical analysis comprising its first and second derivatives was performed. Anatomical landmarks were identified and facial measurements performed. To assess validity the obtained data were compared with manual measurements by orthodontists by means of Lin’s concordance correlation CCC coefficient and reliability was determined by consecutive measurements.

Results

Facial landmarks, such as the soft tissue glabella and nasal tip, could be easily and accurately identified and located. Lin’s CCC showed substantial agreement between digital and manual measurements for 4 of the 7 distances evaluated. Larger discrepancies were due to inadequate image quality and scanning errors. Reliability of consecutive measurements by the same operator was excellent.

Conclusions

In our pilot study the three-dimensional laser-scanning method FastSCAN™ allowed a reliable and accurate identification of anatomical landmarks of the face. The obtained distances between certain landmarks, such as the intercanthal distance, were largely consistent with those from manual measurements. Due to its easy and rapid implementation, the method facilitates facial analysis and could be a clinically valid alternative to manual measurements, when remaining problems in scanning accuracy can be resolved.

【 授权许可】

   
2014 Lippold et al.; licensee BioMed Central.

【 预 览 】
附件列表
Files Size Format View
20150311092122654.pdf 1516KB PDF download
Figure 3. 48KB Image download
Figure 2. 99KB Image download
Figure 3. 62KB Image download
【 图 表 】

Figure 3.

Figure 2.

Figure 3.

【 参考文献 】
  • [1]Arnett GW, McLaughlin RP: Dental and Facial Planning for Orthodontists and Oral Surgeons. London: Mosby; 2003.
  • [2]Schwenzer K, Holberg C, Willer J, Mast G, Ehrenfeld M: 3D-erfassung der gesichtsoberfläche durch topometrie unter verwendung von projizierten weisslichtstreifen. Mund Kiefer Gesichts Chir 1998, 2:130-134.
  • [3]Polhemus - Innovation in Motion™: FastSCAN™ - Official Homepage. http://polhemus.com/scanning-digitizing/fastscan-cobra-ci/ webcite
  • [4]Hennessy RJ, Kinsella A, Waddington JL: 3D laser surface scanning and geometric morphometric analysis of craniofacial shape as an index of cerebro-craniofacial morphogenesis: initial application to sexual dimorphism. Biol Psychiat 2002, 51:507-514.
  • [5]Koenderink JJ, van Doorn AJ: Surface shape and curvature scales. Image Vision Comput 1992, 10:557-564.
  • [6]Liu X, Kim W, Drerup B: 3D characterization and localization of anatomical landmarks of the foot by FastSCAN. Real-Time Imaging 2004, 10:217-228.
  • [7]Liu X, Kim W, Drerup B, Mahadev A: Tibial torsion measurement by surface curvature. Clin Biomech 2005, 20:443-450.
  • [8]NIWA: Statistical calculators NIWA. https://www.niwa.co.nz/node/104318/concordance webcite
  • [9]Lin LI: A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989, 45:255-268.
  • [10]Stoner MM: A photometric analysis of the facial profile: a method of assessing facial change induced by orthodontic treatment. Am J Orthod 1955, 41:453-469.
  • [11]Kau CH, Zhurov A, Scheer R, Bouwman S, Richmond S: The feasibility of measuring three-dimensional facial morphology in children. Orthod Craniofac Res 2004, 7:198-204.
  • [12]Kau CH, Richmond S, Zhurov AI, Knox J, Chestnutt I, Hartles F, Playle R: Reliability of measuring facial morphology with a 3-dimensional laser scanning system. Am J Orthod Dentofacial Orthop 2005, 128:424-430.
  • [13]Schwenzer-Zimmerer K, Haberstok J, Kovacs L, Boerner BI, Schwenzer N, Juergens P, Zeihofer HF, Holberg C: 3D surface measurement for medical application–technical comparison of two established industrial surface scanning systems. J Med Sys 2008, 32:59-64.
  • [14]Joe PS, Ito Y, Shih AM, Oestenstad RK, Lungu CT: Comparison of a novel surface laser scanning anthropometric technique to traditional methods for facial parameter measurements. J Occup Environ Hyg 2012, 9:81-88.
  • [15]McCance AM, Moss JP, Fright WR, James DR, Linney AD: A three dimensional analysis of soft and hard tissue changes following bimaxillary orthognathic surgery in skeletal III patients. Brit J Oral Max Surg 1992, 30:305-312.
  • [16]McCance AM, Moss JP, Wright WR, Linney AD, James DR: A three-dimensional soft tissue analysis of 16 skeletal class III patients following bimaxillary surgery. Brit J Oral Max Surg 1992, 30:221-232.
  • [17]Morris DO, Illing HM, Lee RT: A prospective evaluation of Bass, Bionator and Twin Block appliances. Part II–The soft tissues. Eur J Orthod 1998, 20:663-684.
  • [18]Ismail , Shamique FH, Moss JP, Hennessy R: Three-dimensional assessment of the effects of extraction and nonextraction orthodontic treatment on the face. Am J Orthod Dentofacial Orthop 2002, 121:244-256.
  • [19]Sforza C, Elamin F, Rosati R, Lucchini MA, Tommasi DG, Ferrario VF: Three-dimensional assessment of nose and lip morphology in North Sudanese subjects with Down syndrome. Angle Orthod 2011, 81:107-114.
  • [20]Hajeer MY, Millett DT, Ayoub AF, Siebert JP: Applications of 3D imaging in orthodontics: part I. J Orthod 2004, 31:62-70.
  • [21]Gwilliam JR, Cunningham SJ, Hutton T: Reproducibility of soft tissue landmarks on three-dimensional facial scans. Eur J Orthod 2006, 28:408-415.
  • [22]Moss JP, Campos JC, Linney AD: The analysis of profiles using curvature analysis. Eur J Orthod 1992, 14:457-461.
  文献评价指标  
  下载次数:22次 浏览次数:17次