Validation of a hemoglobin A1c model in patients with type 1 and type 2 diabetes and its use to go beyond the averaged relationship of hemoglobin A1c and mean glucose level
Jerzy Kawiak2  Janusz Krzymien1  Stanislawa Sabalinska2  Marianna I Bak1  Piotr Foltynski2  Piotr Ladyzynski2 
[1] Clinic and Department of Gastroenterology and Metabolic Diseases, Medical University of Warsaw, 1A Banacha street, Warsaw, 02-097, Poland;Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, 4 Trojdena street, Warsaw, 02-109, Poland
关键词: Cultivation of erythrocytes in vitro;    Continuous glucose monitoring;    Chronic glycemia;    Glycemic control;    Diabetes management;    Glycated hemoglobin A1c;    Diabetes mellitus;   
Others  :  1146894
DOI  :  10.1186/s12967-014-0328-5
 received in 2014-07-14, accepted in 2014-11-12,  发布年份 2014
PDF
【 摘 要 】

Background

Glycated hemoglobin A1c (HbA1c) has been used as an index of glycemic control in the management, guidance, and clinical trials of diabetic patients for the past 35 years. The aim of this study was to validate the HbA1c model in patients with type 1 and type 2 diabetes and to use it to support interpretation of HbA1c in different clinical situations.

Methods

The HbA1c model was identified in 30 patients (15 with type 1 diabetes and 15 with type 2 diabetes) by estimating the overall glycation rate constant (k), based on results of continuous glucose monitoring. The model was validated by assessing its ability to predict HbA1c changes in cultures of erythrocytes in vitro and to reproduce results of the A1C-Derived Average Glucose (ADAG) study. The model was used to simulate the influence of different glucose profiles on HbA1c.

Results

The mean k was equal to 1.296 ± 0.216 × 10−9 l mmol−1 s−1 with no difference between type 1 and type 2 diabetes. The mean coefficient of variation of k was equal to 16.7%. The model predicted HbA1c levels in vitro with a mean absolute difference less than 0.3% (3.3 mmol/mol). It reproduced the linear relationship of HbA1c and mean glucose levels established in the ADAG study. The simulation experiments demonstrated that during periods of unstable glycemic control, glycemic profiles with the same mean glucose might result in much different HbA1c levels.

Conclusions

Patients with type 1 and type 2 diabetes are characterized by the same mean value of k, but there is considerable interindividual variation in the relationship of HbA1c and mean glucose level. Results suggest that reciprocal changes in glycation rate and the life span of erythrocytes exist in a wide range of HbA1c values. Thus, for an average patient with diabetes, no modifications of parameters of the glycation model are required to obtain meaningful HbA1c predictions. Interpreting HbA1c as a measure of the mean glucose is fully justified only in the case of stable glycemia. The model and more frequent tests of HbA1c might be used to decrease ambiguity of interpreting HbA1c in terms of glycemic control.

【 授权许可】

   
2014 Ladyzynski et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150403175250557.pdf 737KB PDF download
Figure 8. 38KB Image download
Figure 7. 20KB Image download
Figure 6. 19KB Image download
Figure 5. 72KB Image download
Figure 4. 21KB Image download
Figure 3. 62KB Image download
Figure 2. 64KB Image download
Figure 1. 15KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

【 参考文献 】
  • [1]Nathan DM: The International Expert Committee: International Expert Committee report on the role of the A1C assay in the diagnosis of diabetes. Diabetes Care 2009, 32:1327-1334.
  • [2]Nathan DM, Kuenen J, Borg R, Zheng H, Schoenfeld D, Heine RJ: Translating the A1C assay into estimated average glucose values. Diabetes Care 2008, 31:1473-1478.
  • [3]Beach KW: A theoretical model to predict the behavior of glycosylated hemoglobin levels. J Theor Biol 1979, 81:547-561.
  • [4]Bunn HF, Haney DN, Kamin S, Gabbay KH, Gallop PM: The biosynthesis of human hemoglobin A1c. Slow glycation of hemoglobin in vivo. J Clin Invest 1976, 57:1652-1659.
  • [5]Graf RJ, Halter JB, Porte D Jr: Glycosylated hemoglobin in normal subjects and subjects with maturityonset diabetes. Evidence for a saturable system in man. Diabetes 1978, 27:834-839.
  • [6]Higgins PJ, Bunn HF: Kinetic analysis of the nonenzymatic glycosylation of hemoglobin. J Biol Chem 1981, 256:5204-5208.
  • [7]Ladyzynski P, Wojcicki JM, Bak M, Sabalinska S, Kawiak J, Foltynski P, Krzymien J, Karnafel W: Validation of hemoglobin glycation models using glycemia monitoring in vivo and culturing of erythrocytes in vitro. Ann Biomed Eng 2008, 36:1188-1202.
  • [8]Mortensen HB, Christophersen C: Glucosylation of human haemoglobin A in red blood cells studied in vitro. Kinetics of the formation and dissociation of haemoglobin A1c. Clin Chim Acta 1983, 134:317-326.
  • [9]Kovatchev BP, Flacke F, Sieber J, Breton MD: Accuracy and robustness of dynamical tracking of average glycemia (A1c) to provide real-time estimation of hemoglobin A1c using routine self-monitored blood glucose data. Diabetes Technol Ther 2014, 16:303-309.
  • [10]Osterman-Golkar SM, Vesper HW: Assessment of the relationship between glucose and A1c using kinetic modeling. J Diabetes Complicat 2006, 20:285-294.
  • [11]Tahara Y, Shima K: The response of GHb to stepwise plasma glucose change over time in diabetic patients. Diabetes Care 1993, 16:1313-1314.
  • [12]Ladyzynski P, Wojcicki JM, Bak MI, Sabalinska S, Kawiak J, Foltynski P, Krzymien J, Karnafel W: Hemoglobin glycation rate constant in non-diabetic individuals. Ann Biomed Eng 2011, 39:2721-2734.
  • [13]Cohen M, Boyle E, Delaney C, Shaw J: A comparison of blood glucose meters in Australia. Diabetes Res Clin Pract 2006, 71:113-118.
  • [14]D’Orazio P, Burnett RW, Fogh-Andersen N, Jacobs E, Kuwa K, Kulpmann WR, Larsson L, Lewenstam A, Maas AHJ, Mager G, Naskalski JW, Okorodudu AO: International Federation of Clinical Chemistry and Laboratory Medicine Scientific Division, Working Group on Selective Electrodes and Point-of-Care Testing (IFCC-SD-WG-SEPOCT): Approved IFCC recommendation on reporting results for blood glucose. Clin Chem Lab Med 2006, 44:1486-1490.
  • [15]The Diabetes Research in Children Network (DirectNet) Study Group: The accuracy of the Guardian® RT continuous glucose monitor in children with type 1 diabetes Diabetes Technol Ther 2008, 10:266-272.
  • [16]Hoelzel W, Weykamp C, Jeppsson JO, Miedema K, Barr JR, Goodall I, Hoshino T, John WG, Kobold U, Little R, Mosca A, Mauri P, Paroni R, Susanto F, Takei I, Thienpont L, Umemoto M, Wiedmeyer HM: IFCC Working Group on HbA1c Standardization: IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study. Clin Chem 2004, 50:166-174.
  • [17]Zhang Y, Neelamegham S: Cell counter, blood. In Encyclopedia of Medical Devices and Instrumentation. Edited by Webster JG. John Wiley & Sons, New York; 2006:81-90.
  • [18]Cohen RM, Franco RS, Khera PK, Smith EP, Lindsell CJ, Ciraolo PJ, Palascak MB, Joiner CH: Red cell life span heterogeneity in hematologically normal people is sufficient to alter HbA1c. Blood 2008, 112:4284-4291.
  • [19]Lunn D, Spiegelhalter D, Thomas A, Best N: The BUGS project: evolution, critique and future directions (with discussion). Stat Med 2009, 28:3049-3082.
  • [20]Lehmann ED, Deutsch T, Carson ER, Sonksen PH: AIDA: an interactive diabetes advisor. Comput Meth Programs Biomed 1994, 41:183-203.
  • [21]Nathan DM, Turgeon H, Regan S: Relationship between glycated haemoglobin levels and mean glucose levels over time. Diabetologia 2007, 50:2239-2244.
  • [22]Borg R, Kuenen JC, Carstensen B, Zheng H, Nathan DM, Heine RJ, Nerup J, Borch-Johnsen K, Witte DR: on behalf of the ADAG Study Group: Associations between features of glucose exposure and A1C. The A1C-Derived Average Glucose (ADAG) Study. Diabetes 2010, 59:1585-1590.
  • [23]McCarter RJ, Hempe JM, Chalew SA: Mean blood glucose and biological variation have greater influence on HbA1c levels than glucose instability. An analysis of data from the Diabetes Control and Complications Trial. Diabetes Care 2006, 9:352-355.
  • [24]Furne JK, Springfield JR, Ho SB, Levitt MD: Simplification of the end-alveolar carbon monoxide technique to assess erythrocyte survival. J Lab Clin Med 2003, 142:2-57.
  • [25]Virtue MA, Furne JK, Nuttall FQ, Levitt MD: Relationship between GHb concentration and erythrocyte survival determined from breath carbon monoxide concentration. Diabetes Care 2004, 27:931-935.
  • [26]Selvaraj N, Bobby Z, Sathiyapriya V: Effect of lipid peroxides and antioxidants on glycation of hemoglobin: an in vitro study on human erythrocytes. Clin Chim Acta 2006, 366:190-195.
  • [27]Peterson CM, Jones RL, Koenig RJ, Melvin ET, Lehrman ML: Reversible hematologic sequelae of diabetes mellitus. Ann Intern Med 1977, 86:425-429.
  • [28]Hempe JM, Gomez R, McCarter RJ Jr, Chalew SA: High and low hemoglobin glycation phenotypes in type 1 diabetes: a challenge for interpretation of glycemic control. J Diabetes Complicat 2002, 16:313-320.
  • [29]Gould BJ, Davie SJ, Yudkin SJ: Investigation of the mechanism underlying the variability of glycated haemoglobin in non-diabetic subjects not related to glycaemia. Clin Chim Acta 1997, 260:49-64.
  • [30]Nathan DM, Singer DE, Hurxthal K, Goodson JD: The clinical information value of the glycosylated hemoglobin assay. N Engl J Med 1984, 310:341-346.
  • [31]Sayinalp S, Sozen T, Usman A, Dundar S: Investigation of the effect of poorly controlled diabetes mellitus on erythrocyte life. J Diabetes Complicat 1995, 9:190-193.
  • [32]Lledó-García R, Mazer NA, Karlsson MO: A semi-mechanistic model of the relationship between average glucose and HbA1c in healthy and diabetic subjects. J Pharmacokinet Pharmacodyn 2013, 40:129-142.
  文献评价指标  
  下载次数:76次 浏览次数:34次