| Cilia | |
| Analysis of ependymal ciliary beat pattern and beat frequency using high speed imaging: comparison with the photomultiplier and photodiode methods | |
| Mark A Chilvers2  Kulvinder Sikand3  Chris O'Callaghan1  | |
| [1] Respiratory Medicine, Portex Unit, Institute of Child Health, University College London (UCL) and Great Ormond Street Hospital, 30 Guilford Street, London, WC1N 1EH, London, UK;Division of Pediatric Respiratory Medicine, BC Childrens Hospital, 4480 Oak Street, Vancouver, V6H 3V4, BC, Canada;Department of Infection, Immunity and Inflammation, Division of Child Health, CSB, University of Leicester, Leicester, LE2 7LX, UK | |
| 关键词: Ciliary beat frequency; CSF; Ependymal cilia; Cilia; | |
| Others : 793529 DOI : 10.1186/2046-2530-1-8 |
|
| received in 2011-09-13, accepted in 2012-06-07, 发布年份 2012 | |
PDF
|
|
【 摘 要 】
Background
The aim of this study was to compare beat frequency measurements of ependymal cilia made by digital high speed imaging to those obtained using the photomultiplier and modified photodiode techniques. Using high speed video analysis the relationship of the power and recover strokes was also determined.
Methods
Ciliated strips of ependyma attached to slices from the brain of Wistar rats were incubated at 30°C and observed using a ×50 water immersion lens. Ciliary beat frequency was measured using each of the three techniques: the high speed video, photodiode and photomultiplier. Readings were repeated after 30 minutes incubation at 37°C. Ependymal cilia were observed in slow motion and the precise movement of cilia during the recovery stroke relative to the path travelled during the power stroke was measured.
Results
The mean (95% confidence intervals) beat frequencies determined by the high speed video, photomultiplier and photodiode at 30°C were 27.7 (26.6 to 28.8), 25.5 (24.4 to 26.6) and 20.8 (20.4 to 21.3) Hz, respectively. The mean (95% confidence intervals) beat frequencies determined by the high speed video, photomultiplier and photodiode at 37°C were 36.4 (34 to 39.5), 38.4 (36.8 to 39.9) and 18.8 (16.9 to 20.5) Hz. The inter and intra observer reliability for measurement of ciliary beat frequency was 3.8% and 1%, respectively. Ependymal cilia were observed to move in a planar fashion during the power and recovery strokes with a maximum deviation to the right of the midline of 12.1(11.8 to 13.0)° during the power stroke and 12.6(11.6 to 13.6)° to the left of the midline during the recovery stroke.
Conclusion
The photodiode technique greatly underestimates ciliary beat frequency and should not be used to measure ependymal ciliary beat frequency at the temperatures studied. Ciliary beat frequency from the high speed video and photomultiplier techniques cannot be used interchangeably. Ependymal cilia had minimal deviation to the right side during their power stroke and to the left during the recovery stroke.
【 授权许可】
2012 O'Callaghan et al; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20140705052652924.pdf | 579KB | ||
| Figure 2. | 35KB | Image | |
| Figure 1. | 36KB | Image |
【 图 表 】
Figure 1.
Figure 2.
【 参考文献 】
- [1]Del Bigio MR: Ependymal cells: biology and pathology. Acta Neuropathol 2010, 119:55-73.
- [2]Cathcart RS, Worthington WC Jr: Ciliary movement in the rat cerebral ventricles: clearing action and directions of currents. J Neuropathol Exp Neurol 1964, 23:609-618.
- [3]Yamadori T, Nara K: The directions of ciliary beat on the wall of the lateral ventricle and the currents of the cerebrospinal fluid in the brain ventricles. Scan Electron Microsc 1979, (3):335-340.
- [4]Sawamoto K, Wichterle H, Gonzalez-Perez O, Cholfin JA, Yamada M, Spassky N, Murcia NS, Garcia-Verdugo JM, Marin O, Rubenstein JL, Tessier-Lavigne M, Okano H, Alvarez-Buylla A: New neurons follow the flow of cerebrospinal fluid in the adult brain. Science 2006, 311:629-632.
- [5]Banizs B, Pike MM, Millican CL, Ferguson WB, Komlosi P, Sheetz J, Bell PD, Schwiebert EM, Yoder BK: Dysfunctional cilia lead to altered ependyma and choroid plexus function, and result in the formation of hydrocephalus. Development 2005, 132:5329-5339.
- [6]Ibanez-Tallon I, Pagenstecher A, Fliegauf M, Olbrich H, Kispert A, Ketelsen UP, North A, Heintz N, Omran H: Dysfunction of axonemal dynein heavy chain Mdnah5 inhibits ependymal flow and reveals a novel mechanism for hydrocephalus formation. Hum Mol Genet 2004, 13:2133-2141.
- [7]Koto M, Miwa M, Shimizu A, Tsuji K, Okamoto M, Adachi J: Inherited hydrocephalus in Csk: Wistar-Imamichi rats; Hyd strain: a new disease model for hydrocephalus. Jikken Dobutsu 1987, 36:157-162.
- [8]Koto M, Adachi J, Shimizu A: A new mutation of primary ciliary dyskinesia (PCD) with visceral inversion (Kartagener's Syndrome) and hydrocephalus. Rat News Lett 1987, 18:14-15.
- [9]Monkkonen KS, Hakumaki JM, Hirst RA, Miettinen RA, O'Callaghan C, Mannisto PT, Laitinen JT: Intracerebroventricular antisense knockdown of G alpha i2 results in ciliary stasis and ventricular dilatation in the rat. BMC Neurosci 2007, 8:26. BioMed Central Full Text
- [10]Nakamura Y, Sato K: Role of disturbance of ependymal ciliary movement in development of hydrocephalus in rats. Childs Nerv Syst 1993, 9:65-71.
- [11]Johnson RT, Johnson KP: Hydrocephalus following viral infection: the pathology of aqueductal stenosis developing after experimental mumps virus infection. J Neuropathol Exp Neurol 1968, 27:591-606.
- [12]Kohn DF, Kirk BE, Chou SM: Mycoplasma-induced hydrocephalus in rats and hamsters. Infect Immun 1977, 16:680-689.
- [13]O'Callaghan C, Sikand K, Rutman A: Respiratory and brain ependymal ciliary function. Pediatr Res 1999, 46:704-707.
- [14]Teichtahl H, Wright PL, Kirsner RL: Measurement of in vitro ciliary beat frequency: a television-video modification of the transmitted light technique. Med Biol Eng Comput 1986, 24:193-196.
- [15]Gyi A, O'Callaghan C, Langton JA: Effect of halothane on cilia beat frequency of ciliated human respiratory epithelium in vitro. Br J Anaesth 1994, 73:507-510.
- [16]Dalhamn T, Rylander R: Frequency of ciliary beat measured with a photo-sensitive cell. Nature 1962, 196:592-593.
- [17]Rutland J, Cole PJ: Non-invasive sampling of nasal cilia for measurement of beat frequency and study of ultrastructure. Lancet 1980, 2:564-565.
- [18]Ingels KJ, van Strien HL, Graamans K, Smoorenburg GF, Huizing EH: A study of the photoelectrical signal from human nasal cilia under several conditions. Acta Otolaryngol 1992, 112:831-838.
- [19]Chilvers MA, Rutman A, O'Callaghan C: Ciliary beat pattern is associated with specific ultrastructural defects in primary ciliary dyskinesia. J Allergy Clin Immunol 2003, 112:518-524.
- [20]Stannard W, Rutman A, Wallis C, O'Callaghan C: Central microtubular agenesis causing primary ciliary dyskinesia. Am J Respir Crit Care Med 2004, 169:634-637.
- [21]Grey J: The mechanism of ciliary movement: photographic and stroboscopic analysis of ciliary movement. Proc Royal Soc B 1930, 107:313-322.
- [22]Ballenger JJ, Harding HB, Dawson FW, DeRuyter MG, Moore JA: Measure- ment of ciliary action. Cultural methods for measuring ciliary activity. Am Rev Respir Dis 1966, 93(Suppl):61-66.
- [23]Baba S, Hiramoto Y: A quantitative analysis of ciliary movement by means of high speed microcinematography. J Exp Biol 1970, 52:675-690.
- [24]Greenstone M, Logan-Sinclair R, Cole P: An automated method of recording ciliary beat frequency. IRCS Med Sci 1984, 12:122-131.
- [25]Rautiainen M, Matsune S, Shima S, Sakamoto K, Hanamure Y, Ohyama M: Ciliary beat of cultured human respiratory cells studied with differential interference microscope and high speed video system. Acta Otolaryngol 1992, 112:845-851.
- [26]Chilvers MA, Rutman A, O'Callaghan C: Functional analysis of cilia and ciliated epithelial ultrastructure in healthy children and young adults. Thorax 2003, 58:333-338.
- [27]Sanderson MJ, Sleigh MA: Ciliary activity of cultured rabbit tracheal epithelium: beat pattern and metachrony. J Cell Sci 1981, 47:331-347.
- [28]Chilvers MA, O'Callaghan C: Analysis of ciliary beat pattern and beat frequency using digital high speed imaging: comparison with the photomultiplier and photodiode methods. Thorax 2000, 55:314-317.
- [29]Lechtreck KF, Delmotte P, Robinson ML, Sanderson MJ, Witman GB: Mutations in Hydin impair ciliary motility in mice. J Cell Biol 2008, 180:633-643.
- [30]Hirst RA, Rutman A, Sikand K, Andrew PW, Mitchell TJ, O'Callaghan C: Effect of pneumolysin on rat brain ciliary function: comparison of brain slices with cultured ependymal cells. Pediatr Res 2000, 47:381-384.
- [31]Mohammed BJ, Mitchell TJ, Andrew PW, Hirst RA, O'Callaghan C: The effect of the pneumococcal toxin, pneumolysin on brain ependymal cilia. Microb Pathog 1999, 27:303-309.
- [32]Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1:307-310.
- [33]Altman D: Practical statistics for medical research. Chapman and Hall; 1991.
- [34]Sanderson MJ, Dirksen ER: A versatile and quantitative computer-assisted photoelectronic technique used for the analysis of ciliary beat cycles. Cell Motil 1985, 5:267-292.
- [35]Lechtreck KF, Sanderson MJ, Witman GB: High-speed digital imaging of ependymal cilia in the murine brain. Methods Cell Biol 2009, 91:255-264.
PDF