Early loading of hydrophilic titanium implants inserted in low-mineralized (D3 and D4) bone: one year results of a prospective clinical trial
Daniel Rothamel2  Dennis Rohner1  Uwe Held1 
[1] cfc Hirslanden Medical Center, Aarau, Switzerland;Department of Oral and Maxillofacial Plastic Surgery, University Hospital of Cologne, 50924 Cologne, Germany
关键词: Weak bone;    Bone quality;    Healing time;    Hydrophilic surface;    Titanium implants;   
Others  :  813621
DOI  :  10.1186/1746-160X-9-37
 received in 2013-08-20, accepted in 2013-11-26,  发布年份 2013
PDF
【 摘 要 】

Introduction

Pure titanium is the material of choice for contemporary dental implants. However, superficial reaction of the moderately rough titanium surface with atmospheric components decreases its hydrophilicity. INICELL® represents a chemical alteration and hydrophilization of a moderately rough i. e. sand-blasted and acid-etched titanium surface. The hydrophilicity leads to a more homogenous adsorption of proteins on the implant surface in-vitro, supporting the activation of a higher number of platelets and the generation of a homogenous, complete fibrin matrix in the early phases of osseointegration. This in turn helps to reduce the healing time and enhances the predictability of osseointegration in compromised bony situations.

The objective of this case series trial was therefore to investigate if early loading (after 8 weeks) of hydrophilic INICELL implants is feasible in patients with reduced bone quality.

Methods

In 10 patients, 35 hydrophilic implants were placed in sites revealing bone quality class 3 and 4, and uncovered after 4 weeks. Eight weeks later implants were released for loading if the tactile resistance was ≥35 Ncm. Lower resistances resulted in 12 weeks initial healing period. Insertion torque, ISQ, tactile resistance and vertical bone level were evaluated at implant installation, after 4 weeks (uncovering), 8 or 12 weeks (loading), and 12 weeks and one year after loading.

Results

Mean implant insertion torque was 21 Ncm. 31 (88.6%) showed a tactile resistance of >35 Ncm after eight weeks and were released for prosthetic loading. Eight weeks after insertion, one implant (2.9%) had to be removed following a soft tissue complication. One implant had to be removed after 4 weeks due to a technical complication (fractured Osstell-abutment), it was therefore excluded from the analysis.

33 of 34 implants (97%) were loaded to occlusion and were in situ/functional one year after implantation. ISQs increased from 43 at baseline to 63 at eight weeks, and 72 at three months after loading. Then, ISQ remained constant until one year after loading.

Conclusions

Within the limitations of this prospective case series, hydrophilic implants may allow for shortening of the initial healing period even in bone with compromised density.

【 授权许可】

   
2013 Held et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20140710005957682.pdf 544KB PDF download
Figure 4. 63KB Image download
Figure 3. 55KB Image download
Figure 2. 60KB Image download
Figure 1. 55KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

【 参考文献 】
  • [1]Davies JE: Mechanisms of endosseous integration. Int J Prosthodont 1998, 11(5):391-401.
  • [2]Kieswetter K, Schwartz Z, Dean DD, Boyan BD: The role of implant surface characteristics in the healing of bone. Crit Rev Oral Biol Med 1996, 7(4):329-345.
  • [3]Buser D, Broggini N, Wieland M, Schenk RK, Denzer AJ, Cochran DL, Hoffmann B, Lussi A, Steinemann SG: Enhanced bone apposition to a chemically modified SLA titanium surface. J Dent Res 2004, 83(7):529-533.
  • [4]Raghavendra S, Wood MC, Taylor TD: Early wound healing around endosseous implants: a review of the literature. Int J Oral Maxillofac Implants 2005, 20(3):425-431.
  • [5]Hamblin AS: Cytokines and Cytokines Receptors. In In Focus. Edited by Male D. Oxford: England; 1993.
  • [6]Cobourne MT, Sharpe PT: Tooth and jaw: molecular mechanisms of patterning in the first branchial arch. Arch Oral Biol 2003, 48(1):1-14.
  • [7]Kübler NR: Knochenneubildung durch Osteoinduktion: vom demineralisierten Knochen zu rekombinanten Bone morphogenetic proteins. In Experimentelle Grundlagen und klinische Anwendung in der Mund-, Kiefer-, und Gesichtschirurgie. Berlin: Gesichtschirurgie, Quintessenz Verlag; 1998.
  • [8]Tengvall P: Bio-Implant Interface: Improving Biomaterials and Tissue Reaction. Edited by Ellingson JE, Lyngstadaas SP. Boca Raton, London, New York, Washington NDC: CRC Press; 2003. Chapter 16
  • [9]Baier RE, Meyer AE, Natiella JR, Natiella RR, Carter JM: Surface properties determine bioadhesive outcomes: methods and results. Journal of Biomedical Material Research 1984, 18:327-355.
  • [10]Zhao G, Schwartz Z, Wieland M, Rupp F, Geis-Gerstorfer J, Cochran DL, Boyan BD: High surface energy enhances cell response to titanium substrate microstructure. J Biomed Mater Res A 2005, 74(1):49-58.
  • [11]Zhao G, Raines AL, Wieland M, Schwartz Z, Boyan BD: Requirement for both micron- and submicron scale structure for synergistic response of osteoblasts to substrate surface energy and topography. Biomaterials 2007, 28(18):2821-2829.
  • [12]Oates TW, Valderrama P, Bischof M, Nedir R, Jones A, Simpson J, Toutenburg H, Cochran DL: Enhanced implant stability with a chemically modified SLA surface: a randomized pilot study. Int J Oral Maxillofac Implants 2007, 22(5):755-760.
  • [13]Roccuzzo M, Wilson TG Jr: A prospective study of 3 weeks' loading of chemically modified titanium implants in the maxillary molar region: 1-year results. Int J Oral Maxillofac Implants 2009, 24(1):65-72.
  • [14]Millert V, Tugulu S, Schlottig F, Hall H: Alkali treatment of microrough titanium surfaces affects macrophage/monocyte adhesion, platelet activation and architecture of blood clot formation. Eur Cells and Materials 2011, 21:430-444.
  • [15]Stadlinger B, Lode AT, Eckelt U, Range U, Schlottig F, Hefti T, Mai R: Surface conditioned dental implants: an animal study on bone formation. J Clin Periodontol 2009, 36:832-836.
  • [16]Stadlinger B, Ferguson SJ, Eckelt U, Mai R, Lode AT, Loukota R, Schlottig F: Biomechanical evaluation of a titanium implant surface conditioned by a hydroxide ion solution. Br J Oral Maxillofac Surg 2010,  . Dec 20 [Epub ahead of print]
  • [17]Calvo-Guirado JL, Ortiz-Ruiz AJ, Negri B, López-Marí L, Rodriguez-Barba C, Schlottig F: Histological and histomorphometric evaluation of immediate implant placement on a dog model with a new implant surface treatment. Clin Oral Implants Res 2010, 21(3):308-315. Epub 2010 Jan 13
  • [18]Misch CE: Density of bone: effect on treatment plans, surgical approach, healing, and progressive boen loading. Int J Oral Implantol 1990, 6(2):23-31.
  • [19]Lekhom U, Zarb GA: Patient selection and preparation. In Tissue-integrated protheses: osseointegration in clinical dentistry. Edited by Brånemark PI, Zarb GA, Albrektson T. Chicago: Quintessence Publishing; 1985:199-209.
  • [20]Rupp F, Scheideler L, Olshanska N, de Wild M, Wieland M, Geis-Gerstorfer J: Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces. J Biomed Mater Res A 2006, 76(2):323-334.
  • [21]Schwarz F, Herten M, Sager M, Wieland M, Dard M, Becker J: Histological and immunohistochemical analysis of initial and early osseous integration at chemically modified and conventional SLA titanium implants: preliminary results of a pilot study in dogs. Clin Oral Implants Res 2007, 18(4):481-488. Epub 2007 Apr 30
  • [22]Bornstein MM, Valderrama P, Jones AA, Wilson TG, Seibl R, Cochran DL: Bone apposition around two different sandblasted and acid-etched titanium implant surfaces: a histomorphometric study in canine mandibles. Clin Oral Implants Res 2008, 19(3):233-241. Epub 2008 Jan 3
  • [23]Stadlinger B, Lode AT, Eckelt U, Range U, Schlottig F, Hefti T, Mai R: Surface-conditioned dental implants: an animal study on bone formation. J Clin Periodontol 2009, 36(10):882-891. Epub 2009 Sep 7
  • [24]Cornelini R, Cangini F, Covani U, Barone A, Buser D: Immediate restoration of single-tooth implants in mandibular molar sites: a 12-month preliminary report. Int J Oral Maxillofac Implants 2004, 19(6):855-860.
  • [25]Cornelini R, Cangini F, Covani U, Barone A, Buser D: Immediate loading of implants with 3-unit fixed partial dentures: a 12-month clinical study. Int J Oral Maxillofac Implants 2006, 21(6):914-918.
  • [26]Oh JS, Kim SG: Clinical study oft he relationship between implant stability measurements using Periotest and Osstell mentor and bone quality management. Oral Surg Oral Med Oral Pathol Oral Radiol 2012, 113(3):35-40.
  • [27]Al-Nawas B, Brahm R, Grötz KA: Resonanzfrequenzanalyse zur non-invasiven Analyse der Primärstabilität enossaler Implantate in vivo. Z Zahnärztl Implantol 2002, 18(3):142-148.
  • [28]O'Sullivan D, Sennerby L, Meredith N: Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004, 15(4):474-480.
  • [29]Cann CE, Genant HK: Precise measurement of vertebral mineral content using computed tomography. J Comput Assist Tomogr 1980, 4(4):493-500.
  • [30]Naitoh M, Hirukawa A, Katsumata A, Ariji E: Evaluation of voxel values in mandibular cancellous bone: relationship between cone-beam computed tomography and multislice helical computed tomography. Clin Oral Implants Res 2009, 20(5):503-506. Epub 2009 Feb 25
  • [31]Isoda K, Ayukawa Y, Tsukiyama Y, Sogo M, Matsushita Y, Koyano K: Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants. Clin Oral Implants Res 2011,  . May 5. doi:10.1111/j.1600-0501.2011.02203.x. [Epub ahead of print]
  • [32]Homolka P, Beer A, Birkfellner W, Nowotny R, Gahleitner A, Tschabitscher M, Bergmann H: Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 2002, 224(1):247-252.
  • [33]Rabel A, Köhler SG, Schmidt-Westhausen AM: Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig 2007, 11(3):257-265. Epub 2007 Mar 31
  • [34]Ostman PO, Hellman M, Sennerby L: Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res 2005, 7(Suppl 1):S60-S69.
  • [35]Sjöström M, Sennerby L, Nilson H, Lundgren S: Reconstruction of the atrophic edentulous maxilla with free iliac crest grafts and implants: a 3-year report of a prospective clinical study. Clin Implant Dent Relat Res 2007, 9(1):46-59.
  • [36]Sennerby L, Meredith N: Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008, 47:51-66.
  • [37]Degidi M, Daprile G, Piattelli A: Primary Stability Determination by Means of Insertion Torque and RFA in a Sample of 4,135 Implants. Clin Implant Dent Relat Res 2010,  . Sep 17. doi:10.1111/j.1708-8208.2010.00302.x. [Epub ahead of print]
  • [38]Glauser R, Sennerby L, Meredith N, Rée A, Lundgren A, Gottlow J, Hämmerle CH: Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004, 15(4):428-434.
  • [39]Bornstein MM, Hart CN, Halbritter SA, Morton D, Buser D: Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values. Clin Implant Dent Relat Res 2009, 11(4):338-347. Epub 2009 Apr 23
  • [40]Fischer K, Bäckström M, Sennerby L: Immediate and early loading of oxidized tapered implants in the partially edentulous maxilla: a 1-year prospective clinical, radiographic, and resonance frequency analysis study. Clin Implant Dent Relat Res 2009, 11(2):69-80. Epub 2008 Apr 1
  • [41]Ostman PO, Hellman M, Sennerby L: Immediate occlusal loading of implants in the partially edentate mandible: a prospective 1-year radiographic and 4-year clinical study. Int J Oral Maxillofac Implants 2008, 23(2):315-322.
  • [42]Schätzle M, Männchen R, Balbach U, Hämmerle CH, Toutenburg H, Jung RE: Stability change of chemically modified sandblasted/acid-etched titanium palatal implants. A randomized-controlled clinical trial. Clin Oral Implants Res 2009, 20(5):489-495. Epub 2009 Mar 11
  • [43]Heberer S, Kilic S, Hossamo J, Raguse JD, Nelson K: Rehabilitation of irradiated patients with modified and conventional sandblasted acid-etched implants: preliminary results of a split-mouth study. Clin Oral Implants Res 2011, 22(5):546-551.
  • [44]Ganeles J, Zöllner A, Jackowski J, ten Bruggenkate C, Beagle J, Guerra F: Immediate and early loading of Straumann implants with a chemically modified surface (SLActive®) in the posterior mandible and maxilla: 1-year results from a prospective multicenter study. Clin. Oral Impl Res 2008, 19:1119-1128.
  • [45]Bornstein MM, Wittneben JG, Brägger U, Buser D: Early loading at 21 days of non-submerged titanium implants with a chemically modified sandblasted and acid-etched surface: 3-year results of a prospective study in the posterior mandible. J Periodontol 2010, 81(6):809-818.
  • [46]Luongo G, Oteri G: A noninterventional study documenting use and success of implants with a new chemically modified titanium surface in daily dental practice. J Oral Implantol 2010, 36(4):305-314.
  • [47]Berglundh T, Abrahamsson I, Albouy JP, Lindhe J: Bone healing at implants with a fluoride-modified surface: an experimental study in dogs. Clin Oral Implants Res 2007, 18(2):147-152.
  文献评价指标  
  下载次数:50次 浏览次数:26次