期刊论文详细信息
BMC Veterinary Research
Reliability and Identification of Aortic Valve Prolapse in the Horse
Mark Bowen1  Gayle D Hallowell1 
[1] School of Veterinary Medicine and Science (SVMS), University of Nottingham, Sutton Bonington Campus, Sutton Bonington, Leicestershire, LE12 5RD, UK
关键词: Reproducibility;    Repeatability;    Echocardiography;    Equine;    Cardiology;   
Others  :  1119629
DOI  :  10.1186/1746-6148-9-9
 received in 2012-06-26, accepted in 2013-01-08,  发布年份 2013
PDF
【 摘 要 】

Background

The objectives were to determine and assess the reliability of criteria for identification of aortic valve prolapse (AVP) using echocardiography in the horse.

Results

Opinion of equine cardiologists indicated that a long-axis view of the aortic valve (AoV) was most commonly used for identification of AVP (46%; n=13). There was consensus that AVP could be mimicked by ultrasound probe malignment. This was confirmed in 7 healthy horses, where the appearance of AVP could be induced by malalignment. In a study of a further 8 healthy horses (5 with AVP) examined daily for 5 days, by two echocardiographers standardized imaging guidelines gave good to excellent agreement for the assessment of AVP (kappa>0.80) and good agreement between days and observers (kappa >0.6). The technique allowed for assessment of the degree of prolapse and measurement of the prolapse distance that provided excellent agreement between echocardiographers, days and observers (kappa/ICC>0.8). Assessments made using real-time zoomed images provided similar measurements to the standard views (ICC=0.9), with agreement for the identification of AVP (kappa>0.8).

Short axis views of the AoV were used for identification of AVP by fewer respondents (23%), however provided less agreement for the identification of AVP (kappa>0.6) and only adequate agreement with observations made in long axis (kappa>0.5), with AVP being identified more often in short axis (92%) compared to long axis (76%).

Orthogonal views were used by 31% of respondents to identify the presence of AVP, and 85% to identify cusp. Its identification on both views on 4 days was used to categorise horses as having AVP, providing a positive predictive value of 79% and negative predictive value of 18%. Only the non-coronary cusp (NCC) of the AoV was observed to prolapse in these studies. Prolapse of the NCC was confirmed during the optimisation study using four-dimensional echocardiography, which concurred with the findings of two-dimensional echocardiography.

Conclusions

This study has demonstrated reliable diagnostic criteria for the identification and assessment of AVP that can be used for longitudinal research studies to better define the prevalence and natural history of this condition.

【 授权许可】

   
2013 Hallowell and Bowen; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150208090624278.pdf 1297KB PDF download
Figure 3. 56KB Image download
Figure 2. 71KB Image download
Figure 1. 105KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

【 参考文献 】
  • [1]Shapiro LM, Thwaites B, Westgate C, Donaldson R: Prevalence and clinical significance of aortic valve prolapse. Br Heart J 1985, 54(2):179-183.
  • [2]Marr CM, Reef VB: Physiological valvular regurgitation in clinically normal young racehorses: prevalence and two-dimensional colour flow Doppler echocardiographic characteristics. Equine Vet J Suppl 1995, 19:56-62.
  • [3]Reef VB: Evaluation of ventricular septal defects in horses using two-dimensional and Doppler echocardiography. Equine Vet J Suppl 1995, 19:86-95.
  • [4]Huang HC, Lo SH, Lee SS: Aortic regurgitation detected with Doppler echocardiography in apparently healthy adolescents. J Formos Med Assoc 1999, 98(10):668-671.
  • [5]Chandraratna PA, Samet P, Robinson MJ, Byrd C: Echocardiography of the "floppy" aortic valve. Report of a case. Circulation 1975, 52(5):959-962.
  • [6]Stathopoulos I, Nissirios T, Ostfeld R, Gordon G, Spevack D: A-dip of the aortic valve by M-mode echocardiography. Cardiol J 2009, 16(3):273-275.
  • [7]Reef VB, Spencer P: Echocardiographic evaluation of equine aortic insufficiency. Am J Vet Res 1987, 48(6):904-909.
  • [8]Woldow AB, Parameswaran R, Hartman J, Kotler MN: Aortic regurgitation due to aortic valve prolapse. Am J Cardiol 1985, 55(11):1435-1437.
  • [9]Pedersen HD, Kristensen B, Norby B, Lorentzen KA: Echocardiographic study of mitral valve prolapse in dachshunds. Zentralbl Veterinarmed A 1996, 43(2):103-110.
  • [10]Pedersen HD, Lorentzen KA, Kristensen BO: Echocardiographic mitral valve prolapse in cavalier King Charles spaniels: epidemiology and prognostic significance for regurgitation. Vet Rec 1999, 144(12):315-320.
  • [11]Boudoulas H, Kolibash AJ Jr, Baker P, King BD, Wooley CF: Mitral valve prolapse and the mitral valve prolapse syndrome: a diagnostic classification and pathogenesis of symptoms. Am Heart J 1989, 118(4):796-818.
  • [12]Henneke DR, Potter GD, Kreider JL, Yeates BF: Relationship between condition score, physical measurements and body fat percentage in mares. Equine Vet J 1983, 15(4):371-372.
  • [13]Long KJ, Bonagura JD, Darke PG: Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. Equine Vet J 1992, 24(3):226-235.
  • [14]Reef VB: Echocardiographic examination in the horse. Comp Cont Educ Pract Vet 1990, 12:1312-1319.
  • [15]Anon: Esoate MyLab30 Technical Information. Italy: Esoate; 2005. [Genova]
  • [16]Bland M: Clinical measurement. In An introduction to medical statistics. 3rd edition. Edited by Bland M. Oxford: Oxford University Press; 2000:268-293.
  • [17]Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics 1977, 33:159-174.
  • [18]Patteson MW, Gibbs C, Wotton PR, Cripps PJ: Echocardiographic measurements of cardiac dimensions and indices of cardiac function in normal adult thoroughbred horses. Equine Vet J Suppl 1995, 19:18-27.
  • [19]Kai H, Koyanagi S, Takeshita A: Aortic valve prolapse with aortic regurgitation assessed by Doppler color-flow echocardiography. Am Heart J 1992, 124(5):1297-1304.
  • [20]Byrd BF 3rd, Finkbeiner W, Bouchard A, Silverman NH, Schiller NB: Accuracy and reproducibility of clinically acquired two-dimensional echocardiographic mass measurements. Am Heart J 1989, 118(1):133-137.
  • [21]Bowen IM: Physiological studies of the equine aortic valve. London: Royal Veterinary College, University of London; 2006.
  • [22]Bowen IM, Marr CM, Chester AH, Wheeler-Jones CP, Elliott J: In-vitro contraction of the equine aortic valve. J Heart Valve Dis 2004, 13(4):593-599.
  • [23]Messier RH Jr, Bass BL, Aly HM, Jones JL, Domkowski PW, Wallace RB, Hopkins RA: Dual structural and functional phenotypes of the porcine aortic valve interstitial population: characteristics of the leaflet myofibroblast. J Surg Res 1994, 57(1):1-21.
  • [24]Chester AH, Misfeld M, Yacoub MH: Receptor-mediated contraction of aortic valve leaflets. J Heart Valve Dis 2000, 9(2):250-254. discussion 254–255
  • [25]Pedersen HD, Lorentzen KA, Kristensne BO: Observer Variation in the Two-Dimensional Echocardiographic Evaluation of Mitral Valve Prolapse in Dogs. Vet Radiol Ultrasound 1996, 37(5):367-372.
  • [26]Wann LS, Gross CM, Wakefield RJ, Kalbfleisch JH: Diagnostic precision of echocardiography in mitral valve prolapse. Am Heart J 1985, 109(4):803-808.
  • [27]Olsen LH, Fredholm M, Pedersen HD: Epidemiology and inheritance of mitral valve prolapse in Dachshunds. J Vet Intern Med 1999, 13(5):448-456.
  • [28]Pedersen HD, Olsen LH, Mow T, Christensen NJ: Neuroendocrine changes in Dachshunds with mitral valve prolapse examined under different study conditions. Res Vet Sci 1999, 66(1):11-17.
  • [29]Bulwer BE, Rivero JL: Protocol and Nomenclature in Transthoracic Echocardiography. In Essential Echocardiography. Edited by Ryding A. Philadelphia: Churchill Livingstone Elsevier; 2008.
  • [30]Sisson S: Blood-vascular system of the heart. In The Anatomy Of The Domestic Animals. 2nd edition. Philadelphia: W. B. Saunders; 1914:617-631.
  文献评价指标  
  下载次数:23次 浏览次数:7次