【 摘 要 】

The evaluation of a membrane bioreactor (MBR) for pretreatment of reverse osmosis (RO) in order to reuse and reclamation of industrial town wastewater treatment plant was investigated in this study. Performance of MBR effluent through water quality in term of parameters such as chemical oxygen demand (COD), total suspended solids (TSS), total nitrogen (TN) and total coliform (TC) were measured. Also Silt density index (SDI) was used as indicator for RO feed water. The results of this study demonstrated that MBR produce a high quality permeate water. Approximately 75%, 98%, 74% and 99.9% removal of COD, TSS, TN and TC were recorded, respectively. Also SDI of the permeate effluent from membrane was below 3 for most of the times. It means that pilot yield a high quality treated effluent from the membrane module which can be used as RO feed water.

【 授权许可】

   
2013 Hosseinzadeh et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20140710022314502.pdf 3153KB PDF download
Figure 6. 52KB Image download
Figure 5. 54KB Image download
Figure 4. 62KB Image download
Figure 3. 74KB Image download
Figure 2. 53KB Image download
Figure 1. 77KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

【 参考文献 】
  • [1]Tam LS, Tang TW, Lau GN, Sharma KR, Chen GH: A pilot study for wastewater reclamation and reuse with MBR/RO and MF/RO systems. Desalination 2007, 202:106-113.
  • [2]Wintgens T, Melin T, Scha fer A, Khan S, Muston M, Bixio D, Thoeye C: The role of membrane processes in municipal wastewater reclamation and reuse. Desalination 2006, 187:271-282.
  • [3]Comerton AM, Andrews RC, Bagley DM: Evaluation of an MBR–RO system to produce high quality reuse water: microbial control, DBP formation and removal. Water Res 2005, 39:3982-3990.
  • [4]Meier J, Melin T: Wastewater reclamation by PAC/NF process. Desalination 2005, 178:27-40.
  • [5]Radjenovića J, Petrovića M, Venturac F, Barcelóa D: Rejection of pharmaceuticals in nanofiltration and reverse osmosis membrane drinking water treatment. Water Res 2008, 42:3601-3610.
  • [6]Salahi A, Mohammadi T, Rekabdar F, Mahdavi H: Reverse osmosis of refinery Oily wastewater effluents. Iran J Environ Health Sci & Eng 2010, 7(5):413-422.
  • [7]Gholami M, Mirzaei R, Kalantary R, Sabzali A, Gatei F: Performance evaluation of reverse osmosis technology for selected antibiotics removal from synthetic pharmaceutical wastewater. Iran J Environ Health Sci & Eng 2012, 9:19. 10 December 2012 BioMed Central Full Text
  • [8]Sahar E, David I, Gelman Y, Chikurel H, Aharoni A, Messalem R, Brenner A: the use of RO to remove emerging micropollutants following CAS/UF or MBR treatment of municipal wastewater. Desalination 2011, 273:142-147.
  • [9]Fadhil Abid M, Abdulahad Zablouk M, Muhssen Abid-Alameer A: Experimental study of dye removal from industrial wastewater by membrane technologies of reverse osmosis and nanofiltration. Iran J Environ Health Sci & Eng 2012, 9:17. 5 December 2012 BioMed Central Full Text
  • [10]Alexei G: A simplified RO process design based on understanding of fouling mechanisms. Desalination 1999, 126:227-247.
  • [11]Choia J, Tae-Mun H, Leea S, Hongb S: A systematic approach to determine the fouling index for a RO/NF membrane process. Desalination 2009, 238:117-127.
  • [12]Malamis S, Katsou E, Takopoulos K, Demetriou P, Loizidou M: Assessment of metal removal, biomass activity and RO concentrate treatment in an MBR–RO system. J Hazard Mater 2012, 209:1-8.
  • [13]Sahar E, David I, Gelman Y, Chikurel H, Aharoni A, Messalem R, Brenner A: The use of RO to remove emerging micropollutants following CAS/UF or MBR treatment of municipal wastewater. Desalination 2011, 237:142-147.
  • [14]Kent F, Farahbakhsh K, Mahendran B, Jaklewicz M, Liss S, Zhou H: Water reclamation using reverse osmosis: analysis of fouling propagation given tertiary membrane filtration and MBR pretreatments. J Membr Sci 2011, 382:328-338.
  • [15]Liu HB, Yang C, Pu WH, Zhang JD: Removal of nitrogen from wastewater for reusing to boiler feed-water by an anaerobic/aerobic/membrane bioreactor. Chem Eng J 2008, 2008(140):122-129.
  • [16]Nelson MI, Balakrishnan EE, Sidhu HS, Chen XD: A fundamental analysis of continuous flow bioreactor models and membrane reactor models to process industrial wastewaters. Chem Eng J 2008, 140:521-528.
  • [17]Dhaouadi H, Marrot B: Olive mill wastewater treatment in a membrane bioreactor: process feasibility and performances. Chem Eng J 2008, 145:225-231.
  • [18]Lyko S, Al-Halbouni D, Wintgens T, Janot A, Hollender J, Dott W, Melin T: Polymeric compounds in activated sludge supernatant-characterisation and retention mechanisms at full-scale municipal membrane bioreactor. Water Res 2007, 41:3894-3902.
  • [19]Gehlert G, Abdulkadir M, Fuhrmann J, Hapke J: Dynamic modeling of an ultrafiltration module for use in a membrane bioreactor. J Membr Sci 2005, 248:63-71.
  • [20]Ueda T, Hata K, Kikuoka Y, Seino O: Effects of aeration on suction pressure in a submerged membrane bioreactor. Water Res 1997, 31:489-494.
  • [21]APHA, AWWA: Standard method for the examination of water and wastewater. 20th edition. Washington DC: American Public Health Association; 1998.
  • [22]Hoinkis J, Deowana S, Pantenb V, Figolic A, Huangd R, Driolic E: Membrane Bioreactor (MBR) Technology–a Promising Approach for Industrial Water Reuse. Procedia Eng 2012, 33:234-241.
  • [23]Qin J, Wai M, Tao G, Kekre K, Seah H: Membrane bioreactor study for reclamation of mixed sewage mostly from industrial sources. Sep Purif Technol 2007, 53:296-300.
  • [24]Dialynas E, Diamadopoulos E: Integration of a membrane bioreactor coupled with reverse osmosis for advanced treatment of municipal wastewater. Desalination 2009, 238:309-311.
  • [25]Jun Qin J, Kekre KA, Tao G, Oo MH, Wai MN, Cui Lee T, Viswanath B, Seah H: New option of MBR-RO process for production of NEWater from domestic sewage. J Membr Sci 2006, 272:70-77.
  • [26]Hai F, Tessmer K, Nguyen L, Kang J, Price W, Nghiem L: Removal of micropollutants by membrane bioreactor under temperature variation. J Membr Sci 2011, 383:144-151.
  • [27]Sombatsompop K: Membrane fouling studies in suspended and attached growth membrane bioreactor systems. Asian Institute of Technology: Doctoral thesis; 2007.
  • [28]Zhang J, Chen L, Zeng H, Yan X, Yang H, Ye C: Pilot testing of outside-in MF and UF modules used for cooling tower blowdown pretreatment of power plants. Desalination 2007, 214:287-298.
  文献评价指标  