Temperatures of storage areas in large animal veterinary practice vehicles in the summer and comparison with drug manufacturers’ storage recommendations
Virginia R. Fajt1  Meredyth L. Jones3  Jeff D. Ondrak2 
[1] Veterinary Physiology and Pharmacology, Texas A&M University College of Veterinary Medicine and Biomedical Sciences, College Station, TX, USA;Great Plains Veterinary Educational Center, University of Nebraska-Lincoln, Clay Center, NE, USA;Large Animal Clinical Sciences, Texas A&M University College of Veterinary Medicine and Biomedical Sciences, College Station, TX, USA
关键词: Excessive heat;    Drug stability;    Large animal practice;    Drug storage;    Pharmaceuticals;   
Others  :  1228785
DOI  :  10.1186/s12917-015-0561-z
 received in 2015-02-04, accepted in 2015-09-25,  发布年份 2015
PDF
【 摘 要 】

Background

Large animal veterinarians carry drugs in their practice vehicles in storage areas that are not typically refrigerated. The most common upper limits of manufacturers’ storage temperatures for United States (U.S.)-approved non-refrigerated drugs are 25 or 30 °C. Because ambient temperatures in many locations in the U.S. exceed these temperatures during the summer, we measured storage area temperatures over 4 months in the summer of 2013 to evaluate the extent to which labeled storage temperatures are exceeded.

Methods

A convenience sample of 12 vehicles from 5 central Texas practices and 12 vehicles from 4 south central Nebraska practices was used. Temperatures were recorded in one drug storage compartment in each vehicle from May 15 – September 16, 2013, at 15-minute intervals using a self-contained, battery operated temperature recording device.

Results

The highest temperatures recorded in a storage unit were 54.4 and 47.7 °C in Texas and Nebraska, respectively. The mean temperature recorded across all 24 storage units was 29.1 °C, with a mean of 26.9 °C in Nebraska and 31.4 °C in Texas. In Nebraska, at least one temperature over 25 °C was recorded on a mean of 111/124 days and a mean of 63 % of total logger readings. In Texas, temperatures over 25 °C were recorded on a mean of 123/124 days and a mean of 95 % of total logger readings.

Conclusions

Temperatures in storage units in participating veterinary practice vehicles exceeded labeled drug storage temperatures a significant portion of the summer of 2013. More research is needed to determine whether these excursions above the manufacturers’ recommended storage temperatures alter efficacy of stored drugs.

【 授权许可】

   
2015 Ondrak et al.

【 预 览 】
附件列表
Files Size Format View
20151019031714882.pdf 567KB PDF download
Fig. 1. 51KB Image download
【 图 表 】

Fig. 1.

【 参考文献 】
  • [1]U.S. Pharmacopeia. General Notices and Requirements Applying to Standards, Tests, Assays, and Other Specifications of the United States Pharmacopeia. USP 33-NF 28 Reissue. [http://www.usp.org/sites/default/files/usp_pdf/EN/USPNF/USP33-NF28-ReissueGeneralNotices.pdf]. Accessed on September 30, 2015.
  • [2]U.S. Pharmacopeia: General Notices and Requirements Applying to Standards, Tests, Assays, and Other Specifications of the United States Pharmacopeia. USP 32. [http://www.usp.org/sites/default/files/usp_pdf/EN/USPNF/generalNoticesandRequirementsFinal.pdf]. Accessed on September 30, 2015.
  • [3]U.S. Department of Health and Human Services: Guidance for Industry #5 Drug Stability Guidelines. [http://www.fda.gov/downloads/animalveterinary/guidancecomplianceenforcement/guidanceforindustry/ucm051556.pdf]. Accessed on September 30, 2015.
  • [4]Gottwald MD, Akers LC, Liu PK, Orsulak PJ, Corry MD, Bacchetti P, Fields SM, Lowenstein DH, Alldredge BK. Prehospital stability of diazepam and lorazepam. Am J Emerg Med. 1999; 17:333-7.
  • [5]DuBois WC. Drug storage temperatures in rescue vehicles. J Emerg Med. 2000; 18:345-8.
  • [6]Helm M, Castner TH, Lampl L. Environmental temperature stress on drugs in prehospital emergency medical service. Acta Anaesthesiol Scand. 2003; 47:425-9.
  • [7]De Winter S, Vanbrabant P, Vi NT, Deng X, Spriet I, Van Schepdael A, Gillet JB. Impact of temperature exposure on stability of drugs in a real-world out-of-hospital setting. Ann Emerg Med. 2013; 62:380-7.
  • [8]Szucs P, Allegra JR, Fields LA, Grabiner FR, Lavery R, Prusik T, Tortella B. Storage temperatures of medications on an air medical helicopter. Air Med J. 2000; 19:19-21.
  • [9]Rudland SV, Jacobs AG. Visiting bags: a labile thermal environment. BMJ. 1994; 308:954-6.
  • [10]Brown LH, Wojcik SM, Bailey LC, Tran CD. Can stock rotation effectively mitigate EMS medication exposure to excessive heat and cold? Am J Emerg Med. 2006; 24:14-8.
  • [11]Gammon DL, Su S, Jordan J, Patterson R, Finley PJ, Lowe C, Huckfeldt R. Alteration in prehospital drug concentration after thermal exposure. Am J Emerg Med. 2008; 26:566-73.
  • [12]Summerhays GES. Monitoring of temperature in cars with regard to the pharmaceutical precautions of medicine storage. Eq Vet Educ. 2000; 12:307-11.
  • [13]U.S. Pharmacopeia: General Notices and Requirements Applying to Standards, Tests, Assays, and Other Specifications of the United States Pharmacopeia. USP 34. [http://www.usp.org/sites/default/files/usp_pdf/EN/USPNF/USP34-NF29General%20Notices.pdf]. Accessed on September 30, 2015.
  • [14]Haberleitner A, Schauberger G, Horak J, Schmerold I. Thermal drug storage conditions in veterinary vehicles – a one-year field study in Austria. Wiener Tierärztliche Monatsschrift. 2014; 101:110-9.
  • [15]Valenzuela TD, Criss EA, Hammargren WM, Schram KH, Spaite DW, Meislin HW, Clark JB. Thermal stability of prehospital medications. Ann Emerg Med. 1989; 18:173-6.
  • [16]Traub WH, Leonhard B. Heat stability of the antimicrobial activity of sixty-two antibacterial agents. J Antimicrob Chemother. 1995; 35:149-54.
  • [17]Ballereau F, Prazuck T, Schrive I, Lafleuriel MT, Rozec D, Fisch A, Lafaix C. Stability of essential drugs in the field: results of a study conducted over a two-year period in Burkina Faso. Am J Trop Med Hyg. 1997; 57:31-6.
  • [18]McMullan JT, Pinnawin A, Jones E, Denninghoff K, Siewart N, Spaite DW, Zaleski E, Silbergleit R. The 60-day temperature-dependent degradation of midazolam and lorazepam in the prehospital environment. Prehosp Emerg Care. 2013; 17:1-7.
  • [19]Berendsen BJ, Elbers IJ, Stolker AA. Determination of the stability of antibiotics in matrix and reference solutions using a straightformward procedure applying mass spectrometric detection. Food Addit Contam Part A Chem Anal Control Expo Risk Assess. 2011; 28:1657-66.
  • [20]Concannon J, Lovitt H, Ramage M, Tai LH, McDonald C, Sunderland VB. Stability of aqueous solutions of amoxicillin sodium in the frozen and liquid states. Am J Hosp Pharm. 1986; 43:3027-30.
  • [21]Sylvestri MF, Makoid MC. Stability of ampicillin trihydrate suspension in amber plastic oral syringes. Am J Hosp Pharm. 1986; 43:1496-8.
  • [22]Nicholas E, Hess G, Colton HR. Degradation of penicillin, ticarcillin, and carbenicillin resulting of unit doses. N Eng J Med. 1982; 306:547-8.
  • [23]Injac R, Djordjevic-Milic V, Srdjenovic B. Thermostability testing and degradation profiles of doxycycline in bulk, tablets, and capsules by HPLC. J Chromatogr Sci. 2007; 45:623-8.
  文献评价指标  
  下载次数:19次 浏览次数:20次