Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up
A Leithner1  M Trennheuser1  M Pechmann1  P Sadoghi1  J Friesenbichler1  W Maurer-Ertl1 
[1] Department of Orthopaedic Surgery, Medical University of Graz, Graz, Austria
关键词: Chromium;    Cobalt;    Prosthetic wear;    Total hip arthroplasty;    Hip resurfacing;   
Others  :  1150121
DOI  :  10.1186/1471-2474-13-56
 received in 2011-08-03, accepted in 2012-03-27,  发布年份 2012
PDF
【 摘 要 】

Background

Metal-on-metal hip resurfacing is an alternative to metal-on-metal total hip arthroplasty, especially for young and physically active patients. However, wear which might be detected by increased serum ion levels is a matter of concern.

Methods

The aims of this preliminary study were to determine the raise of metal ion levels at 2-years follow-up in a prospective setting and to evaluate differences between patients with either resurfacing or total hip arthroplasty. Furthermore we investigated if the inclination of the acetabular component and the arc of cover would influence these findings. Therefore, 36 patients were followed prospectively.

Results

The results showed increments for Co and Cr in both implant groups. Patients treated with large-diameter total hip arthroplasty showed fourfold and threefold, respectively, higher levels for Co and Cr compared to the resurfacing group (Co: p < 0,001 and Cr: p = 0,005). Nevertheless, we observed no significant correlation between serum ion levels, inclination and arc of cover.

Discussion

In order to clarify the biologic effects of ion dissemination and to identify risks concerning long-term toxicity of metals, the exposure should be monitored carefully. Therefore, long-term studies have to be done to determine adverse effects of Co and Cr following metal-on-metal hip replacement.

【 授权许可】

   
2012 Maurer-Ertl et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150405143533708.pdf 568KB PDF download
Figure 2. 65KB Image download
Figure 1. 97KB Image download
【 图 表 】

Figure 1.

Figure 2.

【 参考文献 】
  • [1]Matthies A, Underwood R, Cann P, Ilo K, Nawaz Z, Skinner J, Hart AJ: Retrieval analysis of 240 metal-on-metal hip components, comparing modular total hip replacement with hip resurfacing. J Bone Joint Surg Br 2010, 93:307-314.
  • [2]deSouza RM, Parsons NR, Oni T, Dalton P, Costa M, Krikler S: Metal ion levels following resurfacing arthroplasty of the hip: serial results over a ten-year period. J Bone Joint Surg Br 2010, 92:1642-1647.
  • [3]Garbuz DS, Tanzer M, Greidanus NV, Masri BA, Duncan CP: The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 2010, 468:318-325.
  • [4]Moroni A, Savarino L, Hoque M, Cadossi M, Baldini N: Do ion levels in hip resurfacing differ from metal-on-metal THA at midterm? Clin Orthop Relat Res 2010, 469:180-187.
  • [5]De Haan R, Campbell PA, Su EP, De Smet KA: Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br 2008, 90:1158-1163.
  • [6]Langton DJ, Joyce TJ, Jameson SS, Lord J, Van Orsouw M, Holland JP, Nargol AV, De Smet KA: Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear. J Bone Joint Surg Br 2011, 93:164-171.
  • [7]Langton DJ, Jameson SS, Joyce TJ, Hallab NJ, Natu S, Nargol AV: Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear. J Bone Joint Surg Br 2010, 92:38-46.
  • [8]Imanishi T, Hasegawa M, Sudo A: Serum metal ion levels after second-generation metal-on-metal total hip arthroplasty. Arch Orthop Trauma Surg 2010, 130:1447-1450.
  • [9]Sauve P, Mountney J, Khan T, De Beer J, Higgins B, Grover M: Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study. J Bone Joint Surg Br 2007, 89:586-590.
  • [10]Back DL, Young DA, Shimmin AJ: How do serum cobalt and chromium levels change after metal-on-metal hip resurfacing? Clin Orthop Relat Res 2005, 438:177-181.
  • [11]Daniel J, Ziaee H, Pradhan C, Pynsent PB, McMinn DJ: Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study. J Bone Joint Surg Br 2007, 89:169-173.
  • [12]Savarino L, Granchi D, Ciapetti G, Cenni E, Nardi Pantoli A, Rotini R, Veronesi CA, Baldini N, Giunti A: Ion release in patients with metal-on-metal hip bearings in total joint replacement: a comparison with metal-on-polyethylene bearings. J Biomed Mater Res 2002, 63:467-474.
  • [13]Engh CA: MacDonald SJ, Sritulanondha S, Thompson A, Naudie D, Engh CA: 2008 John Charnley award: metal ion levels after metal-on-metal total hip arthroplasty: a randomized trial. Clin Orthop Relat Res 2009, 467:101-111.
  • [14]Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP: Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 2006, 77:697-705.
  • [15]Daniel J, Ziaee H, Pradhan C, McMinn DJ: Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings. J Bone Joint Surg Br 2009, 91:176-179.
  • [16]Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV: The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg Br 2008, 90:1143-1151.
  • [17]Langton DJ, Sprowson AP, Joyce TJ, Reed M, Carluke I, Partington P, Nargol AV: Blood metal ion concentrations after hip resurfacing arthroplasty: a comparative study of articular surface replacement and Birmingham Hip Resurfacing arthroplasties. J Bone Joint Surg Br 2009, 91:1287-1295.
  • [18]Pazzaglia UE, Apostoli P, Congiu T, Catalani S, Marchese M, Zarattini G: Cobalt, chromium and molybdenum ions kinetics in the human body: data gained from a total hip replacement with massive third body wear of the head and neuropathy by cobalt intoxication. Arch Orthop Trauma Surg 2011., 131
  • [19]Steens W, Loehr JF, von Foerster G, Katzer A: Chronic cobalt poisoning in endoprosthetic replacement. Orthopade 2006, 35:860-864.
  • [20]Oldenburg M, Wegner R, Baur X: Severe cobalt intoxication due to prosthesis wear in repeated total hip arthroplasty. J Arthroplasty 2009, 24:825 e815-820.
  • [21]Shimmin AJ, Walter WL, Esposito C: The influence of the size of the component on the outcome of resurfacing arthroplasty of the hip: a review of the literature. J Bone Joint Surg Br 2010, 92:469-476.
  • [22]De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K: Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br 2008, 90:1291-1297.
  • [23]Hart AJ, Hester T, Sinclair K, Powell JJ, Goodship AE, Pele L, Fersht NL, Skinner J: The association between metal ions from hip resurfacing and reduced T-cell counts. J Bone Joint Surg Br 2006, 88:449-454.
  • [24]Antoniou J, Zukor DJ, Mwale F, Minarik W, Petit A, Huk OL: Metal ion levels in the blood of patients after hip resurfacing: a comparison between twenty-eight and thirty-six-millimeter-head metal-on-metal prostheses. J Bone Joint Surg Am 2008, 90(Suppl 3):142-148.
  • [25]Savarino L, Granchi D, Ciapetti G, Cenni E, Greco M, Rotini R, Veronesi CA, Baldini N, Giunti A: Ion release in stable hip arthroplasties using metal-on-metal articulating surfaces: a comparison between short- and medium-term results. J Biomed Mater Res A 2003, 66:450-456.
  • [26]Grubl A, Marker M, Brodner W, Giurea A, Heinze G, Meisinger V, Zehetgruber H, Kotz R: Long-term follow-up of metal-on-metal total hip replacement. J Orthop Res 2007, 25:841-848.
  • [27]De Smet K, De Haan R, Calistri A, Campbell PA, Ebramzadeh E, Pattyn C, Gill HS: Metal ion measurement as a diagnostic tool to identify problems with metal-on-metal hip resurfacing. J Bone Joint Surg Am 2008, 90(Suppl 4):202-208.
  • [28]Vendittoli PA, Amzica T, Roy AG, Lusignan D, Girard J, Lavigne M: Metal Ion release with large-diameter metal-on-metal hip arthroplasty. J Arthroplasty 2010, 26:282-288.
  文献评价指标  