期刊论文详细信息
BMC Medical Imaging
Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
Lea Mirian Barbosa da Fonseca2  Emerson Leandro Gasparetto3  Maria Veronica Fonseca Torres de Oliveira2  Maria Julia Gregorio Calas1  Gabriela Martins3  Fernanda Philadelpho Arantes Pereira3 
[1]Department of Breast Imaging, Clínica de Diagnóstico por Imagem (CDPI), Av. Ataulfo de Paiva 669, 2nd floor, Leblon, Rio de Janeiro, RJ 22440-032, Brazil
[2]Department of Nuclear Medicine, Clínica de Diagnóstico por Imagem (CDPI), Av. Ataulfo de Paiva 669, 2nd floor, Leblon, Rio de Janeiro, RJ 22440-032, Brazil
[3]Department of Magnetic Resonance Imaging, Clínica de Diagnóstico por Imagem (CDPI), Av. Ataulfo de Paiva 669, 2nd floor, Leblon, Rio de Janeiro, RJ 22440-032, Brazil
关键词: Breast cancer;    Radioisotopes;    Nuclear medicine;    MR-guided interventional procedures;    Magnetic resonance imaging (MRI);   
Others  :  1090522
DOI  :  10.1186/1471-2342-13-33
 received in 2012-09-10, accepted in 2013-09-11,  发布年份 2013
PDF
【 摘 要 】

Background

Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI.

Methods

Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed.

Results

One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%).

Conclusions

MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast.

【 授权许可】

   
2013 Philadelpho Arantes Pereira et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150128161516487.pdf 2530KB PDF download
Figure 2. 73KB Image download
Figure 1. 85KB Image download
【 图 表 】

Figure 1.

Figure 2.

【 参考文献 】
  • [1]Meeuwis C, Peters NH, Mali WP, Gallardo AM, van Hillegersberg R, Schipper ME, van den Bosch MA: Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet. Eur J Radiol 2007, 62(2):283-288.
  • [2]Landheer ML, Veltman J, van Eekeren R, Zeillemaker AM, Boetes C, Wobbes T: MRI-guided preoperative wire localization of nonpalpable breast lesions. Clin Imaging 2006, 30(4):229-233.
  • [3]David J, Trop I, Lalonde L: Breast procedures guided by magnetic resonance imaging. Can Assoc Radiol J 2005, 56(5):309-318.
  • [4]Liberman L, Morris EA, Dershaw DD, Thornton CM, Van Zee KJ, Tan LK: Fast MRI-guided vacuum-assisted breast biopsy: initial experience. AJR Am J Roentgenol 2003, 181(5):1283-1293.
  • [5]Perlet C, Heinig A, Prat X, Casselman J, Baath L, Sittek H, Stets C, Lamarque J, Anderson I, Schneider P, Taourel P, Reiser M, Heywang-Köbrunner SH: Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast. Eur Radiol 2002, 12(6):1463-1470.
  • [6]Heywang-Köbrunner SH, Sinnatamby R, Lebeau A, Lebrecht A, Britton PD, Schreer I: Interdisciplinary consensus on the uses and technique of MR-guided vacuum-assisted breast biopsy (VAB): results of a European consensus meeting. Eur J Radiol 2009, 72(2):289-294.
  • [7]Yilmaz MH, Kilic F, Icten GE, Aydogan F, Ozben V, Halac M, Olgun DC, Gazioglu E, Celik V, Uras C, Altug ZA: Radio-guided occult lesion localization for breast lesions under computed-aided MRI guidance: the first experience and initial results. Br J Radiol 2012, 85(1012):395-402.
  • [8]van den Bosch MA, Daniel BL: MR-guided interventions of the breast. Magn Reson Imaging Clin N Am 2005, 13(3):505-517.
  • [9]Causer PA, Piron CA, Jong RA, Curpen BN, Luginbuhl CA, Glazier JE, Warner E, Hill K, Muldoon J, Taylor G, Wong JW, Plewes DB: MR imaging–guided breast localization system with medial or lateral access. Radiology 2006, 240(2):369-379.
  • [10]Liberman L: Magnetic resonance imaging guided needle localization. In Breast MRI Diagnosis and Intervention. 1st edition. Edited by Morris EA, Liberman L. New York: Springer; 2005:280-296.
  • [11]Morris EA, Liberman L, Dershaw DD, Kaplan JB, LaTrenta LR, Abramson AF, Ballon DJ: Preoperative MR imaging-guided needle localization of breast lesions. AJR Am J Roentgenol 2002, 178(5):1211-1220.
  • [12]Pilkington Woll JP, Cortés Romera M, García Vicente AM, González García B, Delgado Portela M, Cordero García JM, Pardo García R, Molino Trinidad C, Soriano Castrejón AM: Impact of radioguided occult lesion localization on the correct excision of malignant breast lesions: effect of histology and tumor size. Ann Nucl Med 2011, 25(3):197-203.
  • [13]Paganelli G, Luini A, Veronesi U: Radioguided occult lesion localization (ROLL) in breast cancer: maximizing efficacy, minimizing mutilation. Ann Oncol 2002, 13(12):1839-1840.
  • [14]De Cicco C, Pizzamiglio M, Trifirò G, Luini A, Ferrari M, Prisco G, Galimberti V, Cassano E, Viale G, Intra M, Veronesi P, Paganelli G: Radioguided occult lesion localization (ROLL) and surgical biopsy in breast cancer. Technical aspects. Q J Nucl Med 2002, 46(2):145-151.
  • [15]Luini A, Zurrida S, Paganelli G, Galimberti V, Sacchini V, Monti S, Veronesi P, Viale G, Veronesi U: Comparison of radioguided excision with wire localization of occult breast lesions. Br J Surg 1999, 86(4):522-525.
  • [16]Pleijhuis RG, Graafland M, de Vries J, Bart J, de Jong JS, van Dam GM: Obtaining adequate surgical margins in breast-conserving therapy for patients with early-stage breast cancer: current modalities and future directions. Ann Surg Oncol 2009, 16(10):2717-2730.
  • [17]Mariscal Martínez A, Solà M, de Tudela AP, Julián JF, Fraile M, Vizcaya S, Fernández J: Radioguided localization of nonpalpable breast cancer lesions: randomized comparison with wire localization in patients undergoing conservative surgery and sentinel node biopsy. AJR Am J Roentgenol 2009, 193(4):1001-1009.
  • [18]Medina-Franco H, Abarca-Pérez L, García-Alvarez MN, Ulloa-Gómez JL, Romero-Trejo C, Sepúlveda-Méndez J: Radioguided occult lesion localization (ROLL) versus wire-guided lumpectomy for non-palpable breast lesions: a randomized prospective evaluation. J Surg Oncol 2008, 97(2):108-111.
  • [19]Sarlos D, Frey LD, Haueisen H, Landmann G, Kots LA, Schaer G: Radioguided occult lesion localization (ROLL) for treatment and diagnosis of malignant and premalignant breast lesions combined with sentinel node biopsy: a prospective clinical trial with 100 patients. Eur J Surg Oncol 2009, 35(4):403-408.
  • [20]Thind CR, Desmond S, Harris O, Nadeem R, Chagla LS, Audisio RA: Radio-guided localization of clinically occult breast lesions (ROLL): a DGH experience. Clin Radiol 2005, 60(6):681-686.
  • [21]American College of Radiology (ACR): ACR BI-RADS – magnetic resonance imaging. In Breast Imaging Reporting and Data System, Breast Imaging Atlas. 1st edition. Edited by ACR. Reston, VA: American College of Radiology; 2003.
  • [22]Bedrosian I, Schlencker J, Spitz FR, Orel SG, Fraker DL, Callans LS, Schnall M, Reynolds C, Czerniecki BJ: Magnetic resonance imaging-guided biopsy of mammographically and clinically occult breast lesions. Ann Surg Oncol 2002, 9(5):457-461.
  • [23]Lampe D, Hefler L, Alberich T, Sittek H, Perlet C, Prat X, Taourel P, Amaya B, Koelbl H, Heywang-Kobrunner SH: The clinical value of preoperative wire localization of breast lesions with magnetic resonance imaging – a multicenter study. Breast Cancer Res Treat 2002, 75(2):175-179.
  • [24]Philpotts LE: MR intervention: indications, technique, correlation and histologic. Magn Reson Imaging Clin N Am 2010, 18(2):323-332.
  • [25]Machado RH, Oliveira AC, Rocha AC, Landesmann MC, Martins FP, Lopes SA, Gutfilen B, da Fonseca LM: Radioguided occult lesion localization (ROLL) and excision of breast lesions using technetium-99m-macroaggregate albumin and air injection control. J Exp Clin Cancer Res 2007, 26(3):323-327.
  文献评价指标  
  下载次数:46次 浏览次数:52次