Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
Laurent Béghin2  Denis Theunynck1  Paul Fardy3  Gilles Bui-Xuân4  Jacques Mikulovic1  Rémy Hurdiel1  Jérémy Vanhelst2 
[1]ER3S, EA4110, Université Lille Nord de France, Dunkerque, France
[2]Unité Inserm U995, Université Lille Nord de France, Lille, France
[3]Department of Family, Nutrition, and Exercise Sciences (FNES) Queens College, Flushing, New York, USA
[4]ER3S, Université d'Artois, Villeneuve d'Ascq, France
关键词: Calibration;    Validation;    Exercise;    Accelerometry;    Cut-off;   
Others  :  1163223
DOI  :  10.1186/1471-2458-12-690
 received in 2012-03-05, accepted in 2012-07-11,  发布年份 2012
PDF
【 摘 要 】

Background

Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults.

Methods

Twenty-one healthy adults aged 20–34 years were recruited for the study. Accelerometer data and oxygen uptake (VO2) were measured at sedentary, light, moderate and vigorous levels of PA.

Results

Activity categories and accelerometer counts were: sedentary, 0–15 counts·min−1; light, 16–40 counts·min−1; moderate, 41–85 counts·min−1; and vigorous activity, >; 85 counts·min−1. ANOVA repeated measures was used to determine the relationship between accelerometry data output and oxygen consumption (r = .89; p <; .001). The Bland and Altman method showed good agreement in the assessment of energy expenditure between the indirect calorimetry and the data obtained by the accelerometer.

Conclusions

Results of the study suggest that the Vivago® wrist-worn accelerometer is a valid measure of PA at varying levels of intensity. The study has also defined threshold values at 4 intensities and hence te Vivago® accelerometer may be used to quantify PA in free living conditions among adults. This device has possible application in treating a variety of important health concerns.

【 授权许可】

   
2012 Vanhelst et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150413093351688.pdf 565KB PDF download
Figure 4. 25KB Image download
Figure 3. 22KB Image download
Figure 2. 22KB Image download
Figure 1. 37KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

【 参考文献 】
  • [1]Choi B, Schnall PL, Yang H, Dobson M, Landsbergis P, Israel L, Karasek R, Baker D: Sedentary work, low physical job demand, and obesity in US workers. Am J Med 2010, 53:1088-1101.
  • [2]Craig CL, Marshall AL, Sjöström M, Bauman AE, Booth ML, Ainsworth BE, Pratt M, Ekelund U, Yngve A, Sallis JF, Oja P: International physical activity questionnaire: 12-country reliability and validity. Med Sci Sports Exerc 2003, 35:1381-1395.
  • [3]De Jonge L, DeLany JP, Nguyen T, Howard J, Hadley EC, Redman LM, Ravussin E: Validation study of energy expenditure and intake during calorie restriction using doubly labelled water and changes in body composition. Am J Clin Nutr 2007, 85:73-79.
  • [4]Rodriguez G, Béghin L, Michaud L, Moreno LA, Turck D, Gottrand F: Comparison of the TriTrac-R3D accelerometer and a self-report activity diary with heart-rate monitoring for the assessment of energy expenditure in children. Br J Nutr 2002, 87:623-631.
  • [5]Bond DS, Jakicic JM, Unick JL, Vithiananthan S, Pohl D, Roye GD, Ryder BA, Sax HC, Wing RR: Pre- to postoperative physical activity changes in bariatric surgery patients: self report vs. objective measures. Obesity 2010, 18:2395-2397.
  • [6]Shephard RJ: Limits to the measurement of physical activity by questionnaires. Br J Sports Med 2003, 37:197-206.
  • [7]Coleman KJ, Saelens BE, Wiedrich-Smith MD, Finn JD, Esptein LH: Relationships between TriTrac-R3D vectors, heart rate, and self-report in obese children. Med Sci Sports Exerc 1997, 29:1535-1542.
  • [8]Chen KY, Bassett DR: The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc 2005, 37:S490-S500.
  • [9]Béghin L, Castera M, Manios Y, Gilbert CC, Kersting M, De Henauw S, Kafatos A, Gottrand F, Molnar D, Sjöström M, Leclercq C, Widhalm K, Mesana MI, Moreno LA, Libersa C: Quality assurance of ethical issues and regulatory aspects relating to good clinical practices in the HELENA cross-sectional study. Int J Obes 2008, 32:S12-18.
  • [10]Freedson PS, Melanson E, Sirard J: Calibration of the computer science and applications, Inc. accelerometer. Med Sci Sports Exerc 1998, 30:777-781.
  • [11]Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 8:307-310.
  • [12]Vanhelst J, Béghin L, Rasoamanana P, Theunynck D, Meskini T, Iliescu C, Duhamel A, Turck D, Gottrand F: RT3 accelerometer thresholds for physical activity levels in children and adolescents. J Sports Sci 2010, 28:381-387.
  • [13]Treuth MS, Schmitz K, Catellier DJ, McMurray RG, Murray DM, Almeida MJ, Going S, Norman JE, Pate R: Defining accelerometer thresholds for activity intensities in adolescent girls. Med Sci Sports Exer 2004, 36:1259-1266.
  • [14]Puyau MR, Adolph AL, Vohra FA, Butte NF: Validation and calibration of physical activity monitors in children. Obes Res 2002, 10:150-157.
  • [15]Evenson KR, Catellier DJ, Gill K, Ondrak KS, McMurray RG: Calibration of two objective measures of physical activity for children. J Sports Sci 2008, 26:1557-1565.
  • [16]Nichols JF, Morgan CG, Sarkin JA, Sallis JF, Calfas KJ: Validity, reliability, and calibration of the Tritrac accelerometer as a measure of physical activity. Med Sci Sports Exerc 1999, 31:908-912.
  • [17]Freedson PS, Melanson E, Sirard J: Calibration of the computer science and application, Inc accelerometer. Med Sci Sports Exer 1998, 30:777-781.
  • [18]Lötjönen J, Korhonen I, Hirvonen K, Eskelinen S, Myllymäki M, Partinen M: Automatic sleep-wake and nap analysis with a new wrist worn online activity monitoring device vivago WristCare. Sleep 2003, 26:86-90.
  • [19]Zhang S, Rowlands AV, Murray P, Hurst TL: Physical activity classification using the GENEA Wrist-Worn Accelerometer. Med Sci Sports Exerc 2012, 44:742-748.
  • [20]Rey-López JP, Ruiz JR, Vicente-Rodríguez G, Gracia-Marco L, Manios Y, Sjöström M, De Bourdeaudhuij I, Moreno LA: Physical activity does not attenuate the obesity risk of TV viewing in youth. Pediatr Obes 2012., 21
  • [21]Ruiz JR, Ortega FB, Martínez-Gómez D, Labayen I, Moreno LA, De Bourdeaudhuij I, Manios Y, Gonzalez-Gross M, Mauro B, Molnar D, Widhalm K, Marcos A, Beghin L, Castillo MJ, Sjöström M: Objectively measured physical activity and sedentary time in European adolescents: the HELENA study. Am J Epidemiol 2011, 174:173-184.
  • [22]Vanhelst J, Zunquin G, Theunynck D, Mikulovic J, Bui-Xuan G, Beghin L: Equivalence of accelerometer data for walking and running: treadmill versus on land. J Sports Sci 2009, 27:669-675.
  • [23]Rowlands AV, Thomas PW, Eston RG, Topping R: Validation of the RT3 triaxial accelerometer for the assessment of physical activity. Med Sci Sports Exerc 2004, 36:518-524.
  文献评价指标  
  下载次数:50次 浏览次数:111次