Size of cup affects the anterior capsular distance in total hip arthroplasty, as measured with ultrasound
Hans Wingstrand2  Otto Robertsson2  Justinas Stucinskas1  Valdemaras Loiba1  Sarunas Tarasevicius2 
[1] Department of Orthopedics, Lund University Hospital, Getingevagen 4, Lund 22185, Sweden;Departments of Orthopedics, Lithuanian University of Health Sciences, Eiveniu 2, Kaunas LT-50009, Lithuania
关键词: THA;    Capsular distance;    Cup size;    Sonography;   
Others  :  1128876
DOI  :  10.1186/1471-2474-15-23
 received in 2013-08-30, accepted in 2014-01-17,  发布年份 2014
PDF
【 摘 要 】

Background

Previously was found that sonography is a reliable method to measure a capsular distance in total hip arthroplasty hips. The aim of our current study was to investigate the relation between the implanted size of the cup and the anterior capsular distance, as measured with ultrasound one year after THA.

Methods

50 osteoarthritis (OA) patients operated on with total hip arthroplasty one year before were included in the study and the anterior capsular distance was measured sonographically. Patients were grouped with respect to cup size. The correlation between the implanted cup size and capsular distance was determined.

Results

The mean capsular distance in the whole group was 1.37 (SD 0.19) cm. The mean capsular distance in the group with small cups was 1.27 (SD 0.13) cm, in large cups it was 1.45 (SD 0.20) cm, p = 0.02. Spearman correlation analysis showed a statistically significant correlation between a greater capsular distance and the larger size of the cup (r = 0.5, p < 0.0001).

Conclusion

The greater capsular distance in successful THA hips is affected by cup size. We propose that this should be considered when evaluating sonography of the anterior capsular distance after THA.

【 授权许可】

   
2014 Tarasevicius et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20150225113013605.pdf 430KB PDF download
Figure 2. 121KB Image download
Figure 1. 92KB Image download
【 图 表 】

Figure 1.

Figure 2.

【 参考文献 】
  • [1]Földes K, Gaal M, Balint P, Nemenyi K, Kiss C, Balint G, Buchanan W: Ultrasonography after hip arthroplasty. Skeletal Radiol 1992, 21(5):297-299.
  • [2]van Holsbeeck MT, Eyler WR, Sherman LS, Lombardi TL, Mezger E, Verner JJ, Schurman JR, Jonsson K: Detection of infection in loosened hip prostheses: efficacy of sonography. AJR Am J Roentgenol 1994, 163(2):381-384.
  • [3]Long SS, Surrey D, Nazarian LN: Common sonographic findings in the painful hip after hip arthroplasty. J Ultrasound Med 2012, 31(2):301-312.
  • [4]Kesteris U, Jonsson K, Robertsson O, et al.: Polyethylene wear and synovitis in total hip arthroplasty: A sonographic study of 48 hips. J Arthroplasty 1999, 14(2):138-143.
  • [5]Robertsson O, Wingstrand H, Kesteris U, Jonsson K, Onnerfalt R: Intracapsular pressure and loosening of hip prostheses. Preoperative measurements in 18 hips. Acta Orthop Scand 1997, 68(3):231-234.
  • [6]Tarasevicius S, Robertsson O, Kesteris U, Kalesinskas RJ, Wingstrand H: Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty: a sonographic and radiographic study of 39 patients. Acta Orthop 2008, 79(4):489-493.
  • [7]Tarasevicius S, Skikas L, Mitraite D, Torii Y, Kesteris U, Wingstrand H: Sonography in total hip arthroplasty. Ultraschall Med 2007, 28(5):475-478.
  • [8]Wingstrand H, Wingstrand A: Biomechanics of the hip joint capsule - a mathematical model and clinical implications. Clin Biomech (Bristol, Avon) 1997, 12(5):273-280.
  • [9]Hrubina M, Behounek J, Skotak M: Mid-term results of cementless ultima cups in primary total hip replacements. Acta Chir Orthop Traumatol Cech 2008, 75(3):205-211.
  文献评价指标  
  下载次数:14次 浏览次数:14次