期刊论文详细信息
BMC Cardiovascular Disorders
Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case–control study
Ruediger Christian Braun-Dullaeus1  Christian Praast1  Georg Ertl2  Octavian Maniuc2  Wolfram Voelker2  Joerg Herold1  Mohammad A. Sherif2 
[1] Cardiology Department, Magdeburg University Clinic, Magdeburg, Germany;Cardiology Department, Wuerzburg University Clinic, Oberduerrbacher Street 6, Wuerzburg, 97080, Germany
关键词: Echocardiography;    Sizing;    TAVI;   
Others  :  1221237
DOI  :  10.1186/s12872-015-0072-7
 received in 2015-03-20, accepted in 2015-07-21,  发布年份 2015
PDF
【 摘 要 】

Background

Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI.

Methods

We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE.

Results

Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 % versus 45.6 %, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25).

Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 % versus 12.9 %, p = 0.027).

Conclusions

Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE.

【 授权许可】

   
2015 Sherif et al.

【 预 览 】
附件列表
Files Size Format View
20150729011332234.pdf 2314KB PDF download
Fig. 2. 44KB Image download
Fig. 1. 19KB Image download
【 图 表 】

Fig. 1.

Fig. 2.

【 参考文献 】
  • [1]Detaint D, Lepage L, Himbert D, Brochet E, Messika-Zeitoun D, Iung B, et al.: Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. JACC Cardiovasc Interv 2009, 2(9):821-7.
  • [2]Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, et al.: Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv 2009, 2(9):811-20.
  • [3]Tuzcu EM, Kapadia SR, Schoenhagen P: Multimodality quantitative imaging of aortic root for transcatheter aortic valve implantation: more complex than it appears. J Am Coll Cardiol 2010, 55(3):195-7.
  • [4]Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, et al.: Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 2012, 59(14):1275-86.
  • [5]Jilaihawi H, Doctor N, Kashif M, Chakravarty T, Rafique A, Makar M, et al.: Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol 2013, 61(9):908-16.
  • [6]Binder RK, Webb JG, Willson AB, Urena M, Hansson NC, Norgaard BL, et al.: The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial. J Am Coll Cardiol 2013, 62(5):431-8.
  • [7]Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M, et al.: 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 2012, 59(14):1287-94.
  • [8]Willson AB, Webb JG, Freeman M, Wood DA, Gurvitch R, Thompson CR, et al.: Computed tomography-based sizing recommendations for transcatheter aortic valve replacement with balloon-expandable valves: Comparison with transesophageal echocardiography and rationale for implementation in a prospective trial. J Cardiovasc Comput Tomogr 2012, 6(6):406-14.
  • [9]Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Wenaweser P, et al.: Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol 2007, 50(1):69-76.
  • [10]Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, et al.: Authors/Task Force M: Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg 2012, 42(4):S1-44.
  • [11]Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, et al.: Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J 2011, 32(2):205-17.
  • [12]Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, et al.: Recommendations for chamber quantification: a report from the American Society of Echocardiography’s Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005, 18(12):1440-63.
  • [13]Vahanian A, Alfieri O, Al-Attar N, Antunes M, Bax J, Cormier B, et al.: Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European association of cardio-thoracic surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). EuroIntervention 2008, 4(2):193-9.
  • [14]Dashkevich A, Blanke P, Siepe M, Pache G, Langer M, Schlensak C, et al.: Preoperative assessment of aortic annulus dimensions: comparison of noninvasive and intraoperative measurement. Ann Thorac Surg 2011, 91(3):709-14.
  • [15]Kempfert J, Van Linden A, Lehmkuhl L, Rastan AJ, Holzhey D, Blumenstein J, et al.: Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing. Eur J Cardiothorac Surg 2012, 42(4):627-33.
  • [16]Messika-Zeitoun D, Serfaty JM, Brochet E, Ducrocq G, Lepage L, Detaint D, et al.: Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 2010, 55(3):186-94.
  • [17]Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH: Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 2008, 1(1):74-81.
  • [18]Thubrikar M, Piepgrass WC, Shaner TW, Nolan SP: The design of the normal aortic valve. Am J Physiol 1981, 241(6):H795-801.
  • [19]Schultz CJ, Moelker A, Piazza N, Tzikas A, Otten A, Nuis RJ, et al.: Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer’s guidelines for sizing for percutaneous aortic valve replacement helpful? Eur Heart J 2010, 31(7):849-56.
  • [20]Wuest W, Anders K, Schuhbaeck A, May MS, Gauss S, Marwan M, et al.: Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode. Eur Radiol 2012, 22(1):51-8.
  • [21]Rodes-Cabau J, Webb JG, Cheung A, Ye J, Dumont E, Feindel CM, et al.: Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol 2010, 55(11):1080-90.
  • [22]Dumonteil N, van der Boon RM, Tchetche D, Chieffo A, Van Mieghem NM, Marcheix B, et al.: Impact of preoperative chronic kidney disease on short- and long-term outcomes after transcatheter aortic valve implantation: a Pooled-RotterdAm-Milano-Toulouse In Collaboration Plus (PRAGMATIC-Plus) initiative substudy. Am Heart J 2013, 165(5):752-60.
  文献评价指标  
  下载次数:109次 浏览次数:20次