| BMC Cancer | |
| 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals derived from a single-institution 18F-FDG-directed surgery experience: feasibility and quantification of 18F-FDG accumulation within 18F-FDG-avid lesions and background tissues | |
| Stephen P Povoski2  Douglas A Murrey1  Sabrina M Smith3  Edward W Martin2  Nathan C Hall1  | |
| [1] Division of Molecular Imaging and Nuclear Medicine, Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA | |
| [2] Division of Surgical Oncology, Department of Surgery, Arthur G. James Cancer Hospital and Richard J. Solove Research Institute and Comprehensive Cancer Center, The Ohio State University Wexner Medical Center, Columbus, OH 43210, USA | |
| [3] College of Medicine, The Ohio State University, Columbus, OH 43210, USA | |
| 关键词: Oncologic; Real-time; 18F-FDG-directed surgery; Tumor-to-background ratio; Lesion-to-background ratio; Delayed imaging; Injection-to-scan acquisition time; SUVmax; PET/CT; 18F-FDG; | |
| Others : 855661 DOI : 10.1186/1471-2407-14-453 |
|
| received in 2014-02-10, accepted in 2014-06-13, 发布年份 2014 | |
PDF
|
|
【 摘 要 】
Background
18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) is a well-established imaging modality for a wide variety of solid malignancies. Currently, only limited data exists regarding the utility of PET/CT imaging at very extended injection-to-scan acquisition times. The current retrospective data analysis assessed the feasibility and quantification of diagnostic 18F-FDG PET/CT oncologic imaging at extended injection-to-scan acquisition time intervals.
Methods
18F-FDG-avid lesions (not surgically manipulated or altered during 18F-FDG-directed surgery, and visualized both on preoperative and postoperative 18F-FDG PET/CT imaging) and corresponding background tissues were assessed for 18F-FDG accumulation on same-day preoperative and postoperative 18F-FDG PET/CT imaging. Multiple patient variables and 18F-FDG-avid lesion variables were examined.
Results
For the 32 18F-FDG-avid lesions making up the final 18F-FDG-avid lesion data set (from among 7 patients), the mean injection-to-scan times of the preoperative and postoperative 18F-FDG PET/CT scans were 73 (±3, 70-78) and 530 (±79, 413-739) minutes, respectively (P < 0.001). The preoperative and postoperative mean 18F-FDG-avid lesion SUVmax values were 7.7 (±4.0, 3.6-19.5) and 11.3 (±6.0, 4.1-29.2), respectively (P < 0.001). The preoperative and postoperative mean background SUVmax values were 2.3 (±0.6, 1.0-3.2) and 2.1 (±0.6, 1.0-3.3), respectively (P = 0.017). The preoperative and postoperative mean lesion-to-background SUVmax ratios were 3.7 (±2.3, 1.5-9.8) and 5.8 (±3.6, 1.6-16.2), respectively, (P < 0.001).
Conclusions
18F-FDG PET/CT oncologic imaging can be successfully performed at extended injection-to-scan acquisition time intervals of up to approximately 5 half-lives for 18F-FDG while maintaining good/adequate diagnostic image quality. The resultant increase in the 18F-FDG-avid lesion SUVmax values, decreased background SUVmax values, and increased lesion-to-background SUVmax ratios seen from preoperative to postoperative 18F-FDG PET/CT imaging have great potential for allowing for the integrated, real-time use of 18F-FDG PET/CT imaging in conjunction with 18F-FDG-directed interventional radiology biopsy and ablation procedures and 18F-FDG-directed surgical procedures, as well as have far-reaching impact on potentially re-shaping future thinking regarding the “most optimal” injection-to-scan acquisition time interval for all routine diagnostic 18F-FDG PET/CT oncologic imaging.
【 授权许可】
2014 Povoski et al.; licensee BioMed Central Ltd.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 20140722055005376.pdf | 3071KB | ||
| 141KB | Image | ||
| 108KB | Image |
【 图 表 】
【 参考文献 】
- [1]Hillner BE, Siegel BA, Liu D, Shields AF, Gareen IF, Hanna L, Stine SH, Coleman RE: Impact of positron emission tomography/computed tomography and positron emission tomography (PET) alone on expected management of patients with cancer: initial results from the National Oncologic PET Registry. J Clin Oncol 2008, 26:2155-2161.
- [2]Poeppel TD, Krause BJ, Heusner TA, Boy C, Bockisch A, Antoch G: PET/CT for the staging and follow-up of patients with malignancies. Eur J Radiol 2009, 70:382-392.
- [3]Stroobants S: To PET or not to PET: what are the indications? Eur J Cancer 2011, 47(Suppl 3):S304-S305.
- [4]Czernin J, Allen-Auerbach M, Nathanson D, Herrmann K: PET/CT in oncology: current status and perspectives. Curr Radiol Rep 2013, 1:177-190.
- [5]Schöder H, Gönen M: Screening for cancer with PET and PET/CT: potential and limitations. J Nucl Med 2007, 48(Suppl 1):4S-18S.
- [6]Desai D, Arnold M, Saha S, Hinkle G, Soble D, Frye J, DePalatis L, Mantil J, Satter M, Martin E: Intraoperative gamma detection of FDG distribution in colorectal cancer. Clin Positron Imaging 1999, 2:325.
- [7]Desai DC, Arnold M, Saha S, Hinkle G, Soble D, Fry J, DePalatis LR, Mantil J, Satter M, Martin EW: Correlative whole-body FDG-PET and intraoperative gamma detection of FDG distribution in colorectal cancer. Clin Positron Imaging 2000, 3:189-196.
- [8]Zervos EE, Desai DC, DePalatis LR, Soble D, Martin EW: 18F-labeled fluorodeoxyglucose positron emission tomography-guided surgery for recurrent colorectal cancer: a feasibility study. J Surg Res 2001, 97:9-13.
- [9]Essner R, Hsueh EC, Haigh PI, Glass EC, Huynh Y, Daghighian F: Application of an [(18) F] fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy. J Surg Res 2001, 96:120-126.
- [10]Essner R, Daghighian F, Giuliano AE: Advances in FDG PET probes in surgical oncology. Cancer J 2002, 8:100-108.
- [11]Higashi T, Saga T, Ishimori T, Mamede M, Ishizu K, Fujita T, Mukai T, Sato S, Kato H, Yamaoka Y, Matsumoto K, Senda M, Konishi J: What is the most appropriate scan timing for intraoperative detection of malignancy using 18F-FDG-sensitive gamma probe? Preliminary phantom and preoperative patient study. Ann Nucl Med 2004, 18:105-114.
- [12]Yap JT, Carney JP, Hall NC, Townsend DW: Image-guided cancer therapy using PET/CT. Cancer J 2004, 10:221-233.
- [13]Barranger E, Kerrou K, Petegnief Y, David-Montefiore E, Cortez A, Daraï E: Laparoscopic resection of occult metastasis using the combination of FDG-positron emission tomography/computed tomography image fusion with intraoperative probe guidance in a woman with recurrent ovarian cancer. Gynecol Oncol 2005, 96:241-244.
- [14]Carrera D, Fernandez A, Estrada J, Martin-Comin J, Gamez C: Detection of occult malignant melanoma by 18F-FDG PET-CT and gamma probe. Rev Esp Med Nucl 2005, 24:410-413. [Spanish]
- [15]Franc BL, Mari C, Johnson D, Leong SP: The role of a positron- and high-energy gamma photon probe in intraoperative localization of recurrent melanoma. Clin Nucl Med 2005, 30:787-791.
- [16]Kraeber-Bodéré F, Cariou B, Curtet C, Bridji B, Rousseau C, Dravet F, Charbonnel B, Carnaille B, Le Néel JC, Mirallié E: Feasibility and benefit of fluorine 18-fluoro-2-deoxyglucose-guided surgery in the management of radioiodine-negative differentiated thyroid carcinoma metastases. Surgery 2005, 138:1176-1182.
- [17]Gulec SA, Daghighian F, Essner R: PET-Probe. Evaluation of Technical Performance and Clinical Utility of a Handheld High-Energy Gamma Probe in Oncologic Surgery. Ann Surg Oncol 2006. [Epub ahead of print]
- [18]Meller B, Sommer K, Gerl J, von Hof K, Surowiec A, Richter E, Wollenberg B, Baehre M: High energy probe for detecting lymph node metastases with 18F-FDG in patients with head and neck cancer. Nuklearmedizin 2006, 45:153-159.
- [19]Nwogu C, Fischer G, Tan D, Glinianski M, Lamonica D, Demmy T: Radioguided detection of lymph node metastasis in non-small cell lung cancer. Ann Thorac Surg 2006, 82:1815-1820. discussion 1820
- [20]Curtet C, Carlier T, Mirallié E, Bodet-Milin C, Rousseau C, Barbet J, Kraeber-Bodéré F: Prospective comparison of two gamma probes for intraoperative detection of 18F-FDG: in vitro assessment and clinical evaluation in differentiated thyroid cancer patients with iodine-negative recurrence. Eur J Nucl Med Mol Imaging 2007, 34:1556-1562.
- [21]Gulec SA, Hoenie E, Hostetter R, Schwartzentruber D: PET probe-guided surgery: applications and clinical protocol. World J Surg Oncol 2007, 5:65.
- [22]Gulec SA: PET probe-guided surgery. J Surg Oncol 2007, 96:353-357.
- [23]Hall NC, Povoski SP, Murrey DA, Knopp MV, Martin EW: Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer. World J Surg Oncol 2007, 5:143.
- [24]Piert M, Burian M, Meisetschlager G, Stein HJ, Ziegler S, Nahrig J, Picchio M, Buck A, Siewert JR, Schwaiger M: Positron detection for the intraoperative localisation of cancer deposits. Eur J Nucl Med Mol Imaging 2007, 34:1534-1544.
- [25]Sarikaya I, Povoski SP, Al-Saif OH, Kocak E, Bloomston M, Marsh S, Cao Z, Murrey DA, Zhang J, Hall NC, Knopp MV, Martin EW: Combined use of preoperative 18F FDG-PET imaging and intraoperative gamma probe detection for accurate assessment of tumor recurrence in patients with colorectal cancer. World J Surg Oncol 2007, 5:80.
- [26]Sun D, Bloomston M, Hinkle G, Al-Saif OH, Hall NC, Povoski SP, Arnold MW, Martin EW: Radioimmunoguided surgery (RIGS), PET/CT image-guided surgery, and fluorescence image-guided surgery: past, present, and future. J Surg Oncol 2007, 96:297-308.
- [27]Prior JO, Kosinski M, Delaloye AB, Denys A: Initial report of PET/CT-guided radiofrequency ablation of liver metastases. J Vasc Interv Radiol 2007, 18:801-803.
- [28]Agrawal A, Hall NC, Ringel MD, Povoski SP, Martin EW Jr: Combined use of perioperative TSH-stimulated 18F-FDG PET/CT imaging and gamma probe radioguided surgery to localize and verify resection of iodine scan-negative recurrent thyroid carcinoma. Laryngoscope 2008, 118:2190-2194.
- [29]Cohn DE, Hall NC, Povoski SP, Seamon LG, Farrar WB, Martin EW Jr: Novel perioperative imaging with 18F-FDG PET/CT and intraoperative 18F-FDG detection using a handheld gamma probe in recurrent ovarian cancer. Gynecol Oncol 2008, 110:152-157.
- [30]Hall NC, Povoski SP, Murrey DA, Knopp MV, Martin EW: Bringing advanced medical imaging into the operative arena could revolutionize the surgical care of cancer patients. Expert Rev Med Devices 2008, 5:663-667.
- [31]Moffatt-Bruce SD, Povoski SP, Sharif S, Hall NC, Ross P Jr, Johnson MA, Martin EW Jr: A novel approach to positron emission tomography in lung cancer. Ann Thorac Surg 2008, 86:1355-1357.
- [32]Piert M, Carey J, Clinthorne N: Probe-guided localization of cancer deposits using [(18) F] fluorodeoxyglucose. Q J Nucl Med Mol Imaging 2008, 52:37-49.
- [33]Povoski SP, Hall NC, Martin EW, Walker MJ: Multimodality approach of perioperative 18F-FDG PET/CT imaging, intraoperative 18F-FDG handheld gamma probe detection, and intraoperative ultrasound for tumor localization and verification of resection of all sites of hypermetabolic activity in a case of occult recurrent metastatic melanoma. World J Surg Oncol 2008, 6:1.
- [34]Povoski SP, Sarikaya I, White WC, Marsh SG, Hall NC, Hinkle GH, Martin EW Jr, Knopp MV: Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures. Eur J Nucl Med Mol Imaging 2008, 35:2026-2034.
- [35]van Baardwijk A, Bosmans G, van Suylen RJ, van Kroonenburgh M, Hochstenbag M, Geskes G, Lambin P, De Ruysscher D: Correlation of intra-tumour heterogeneity on 18F-FDG PET with pathologic features in non-small cell lung cancer: a feasibility study. Radiother Oncol 2008, 87:55-58.
- [36]Povoski SP, Neff RL, Mojzisik CM, O’Malley DM, Hinkle GH, Hall NC, Murrey DA Jr, Knopp MV, Martin EW Jr: A comprehensive overview of radioguided surgery using gamma detection probe technology. World J Surg Oncol 2009, 7:11.
- [37]Murrey DA Jr, Bahnson EE, Hall NC, Povoski SP, Mojzisik CM, Young DC, Sharif S, Johnson MA, Abdel-Misih S, Martin EW Jr, Knopp MV: Perioperative (18) F-fluorodeoxyglucose-guided imaging using the becquerel as a quantitative measure for optimizing surgical resection in patients with advanced malignancy. Am J Surg 2009, 198:834-840.
- [38]Gollub MJ, Akhurst TJ, Williamson MJ, Shia J, Humm JL, Wong WD, Paty PB, Guillem JG, Weiser MR, Temple LK, Dauer LT, Jhanwar SC, Kronman RE, Montalvo CV, Miller AR, Larson SM, Margulis AR: Feasibility of ex vivo FDG PET of the colon. Radiology 2009, 252:232-239.
- [39]Klaeser B, Mueller MD, Schmid RA, Guevara C, Krause T, Wiskirchen J: PET-CT-guided interventions in the management of FDG-positive lesions in patients suffering from solid malignancies: initial experiences. Eur Radiol 2009, 19:1780-1785.
- [40]Molina MA, Goodwin WJ, Moffat FL, Serafini AN, Sfakianakis GN, Avisar E: Intra-operative use of PET probe for localization of FDG avid lesions. Cancer Imaging 2009, 9:59-62.
- [41]Mallarajapatna GJ, Kallur KG, Ramanna NK, Susheela SP, Ramachandra PG: PET/CT-guided percutaneous biopsy of isolated intramuscular metastases from postcricoid cancer. J Nucl Med Technol 2009, 37:220-222.
- [42]Hall NC, Povoski SP, Murrey DA, Martin EW Jr, Knopp MV: Ex vivo specimen FDG PET/CT imaging for oncology. Radiology 2010, 255:663-664.
- [43]Nalley C, Wiebeck K, Bartel TB, Bodenner D, Stack BC Jr: Intraoperative radiation exposure with the use of (18) F-FDG-guided thyroid cancer surgery. Otolaryngol Head Neck Surg 2010, 142:281-283.
- [44]de Jong JS, van Ginkel RJ, Slart RH, Lemstra CL, Paans AM, Mulder NH, Hoekstra HJ: FDG-PET probe-guided surgery for recurrent retroperitoneal testicular tumor recurrences. Eur J Surg Oncol 2010, 36:1092-1095.
- [45]Hartemink KJ, Muller S, Smulders YM, Petrousjka Van Den Tol M, Comans EF: Fluorodeoxyglucose F18(FDG)-probe guided biopsy. Ned Tijdschr Geneeskd 2010, 154:A1884. [Dutch]
- [46]Lee GO, Costouro NG, Groome T, Kashani-Sabet M, Leong SPL: The use of intraoperative PET probe to resect metastatic melanoma. BMJ Case Reports 2010. doi:10.1136/bcr.12.2009.2593
- [47]Klaeser B, Wiskirchen J, Wartenberg J, Weitzel T, Schmid RA, Mueller MD, Krause T: PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact. Eur J Nucl Med Mol Imaging 2010, 37:2027-2036.
- [48]García JR, Fraile M, Soler M, Bechini J, Ayuso JR, Lomeña F: PET/CT-guided salvage surgery protocol. Results with ROLL Technique and PET probe. Rev Esp Med Nucl 2011, 30:217-222. [Spanish]
- [49]Kim WW, Kim JS, Hur SM, Kim SH, Lee SK, Choi JH, Kim S, Choi JY, Lee JE, Kim JH, Nam SJ, Yang JH, Choe JH: Radioguided surgery using an intraoperative PET probe for tumor localization and verification of complete resection in differentiated thyroid cancer: A pilot study. Surgery 2011, 149:416-424.
- [50]Manca G, Biggi E, Lorenzoni A, Boni G, Roncella M, Ghilli M, Volterrani D, Mariani G: Simultaneous detection of breast tumor resection margins and radioguided sentinel node biopsy using an intraoperative electronically collimated probe with variable energy window: a case report. Clin Nucl Med 2011, 36:e196-e198.
- [51]Povoski SP, Hall NC, Murrey DA Jr, Chow AZ, Gaglani JR, Bahnson EE, Mojzisik CM, Kuhrt MP, Hitchcock CL, Knopp MV, Martin EW Jr: Multimodal imaging and detection approach to 18F-FDG-directed surgery for patients with known or suspected malignancies: a comprehensive description of the specific methodology utilized in a single-institution cumulative retrospective experience. World J Surg Oncol 2011, 9:152.
- [52]Tatli S, Gerbaudo VH, Feeley CM, Shyn PB, Tuncali K, Silverman SG: PET/CT-guided percutaneous biopsy of abdominal masses: initial experience. J Vasc Interv Radiol 2011, 22:507-514.
- [53]Werner MK, Aschoff P, Reimold M, Pfannenberg C: FDG-PET/CT-guided biopsy of bone metastases sets a new course in patient management after extensive imaging and multiple futile biopsies. Br J Radiol 2011, 84:e65-e67.
- [54]Sainani NI, Shyn PB, Tatli S, Morrison PR, Tuncali K, Silverman SG: PET/CT-guided radiofrequency and cryoablation: is tumor fluorine-18 fluorodeoxyglucose activity dissipated by thermal ablation? J Vasc Interv Radiol 2011, 22:354-360.
- [55]Francis CL, Nalley C, Fan C, Bodenner D, Stack BC Jr: 18F-fluorodeoxyglucose and 131I Radioguided Surgical Management of Thyroid Cancer. Otolaryngol Head Neck Surg 2012, 146:26-32.
- [56]Bains S, Reimert M, Win AZ, Khan S, Aparici CM: A patient with psoriatic arthritis imaged with FDG-PET/CT demonstrated an unusual imaging pattern with muscle and fascia involvement: a case report. Nucl Med Mol Imaging 2012, 46:138-143.
- [57]Vos CG, Hartemink KJ, Muller S, Oosterhuis JW, Meijer S, van den Tol MP, Comans EF: Clinical applications of FDG-probe guided surgery. Acta Chir Belg 2012, 112:414-418.
- [58]Hall NC, Povoski SP, Zhang J, Knopp MV, Martin EW Jr: Use of intraoperative nuclear medicine imaging technology: strategy for improved patient management. Expert Rev Med Devices 2013, 10:149-152.
- [59]Povoski SP, Chapman GJ, Murrey DA Jr, Lee R, Martin EW Jr, Hall NC: Intraoperative detection of 18F-FDG-avid tissue sites using the increased probe counting efficiency of the K-alpha probe design and variance-based statistical analysis with the three-sigma criteria. BMC Cancer 2013, 13:98.
- [60]Cerci JJ, Pereira Neto CC, Krauzer C, Sakamoto DG, Vitola JV: The impact of coaxial core biopsy guided by FDG PET/CT in oncological patients. Eur J Nucl Med Mol Imaging 2013, 40:98-103.
- [61]Win AZ, Aparici CM: Real-time FDG PET/CT-guided bone biopsy in a patient with two primary malignancies. Eur J Nucl Med Mol Imaging 2013, 40:1787-1788.
- [62]Cerci JJ, Huber FZT, Bogoni M: PET/CT-guided biopsy of liver lesions. Clin Transl Imaging 2014, 2:157-163.
- [63]Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, Townsend DW, Berland LL, Parker JA, Hubner K, Stabin MG, Zubal G, Kachelriess M, Cronin V, Holbrook S: Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0. J Nucl Med 2006, 47:885-895.
- [64]Hall N, Murrey D, Povoski S, Barker D, Zhang J, Bahnson E, Chow A, Martin EW, Knopp MV: Evaluation of 18FDG PET/CT image quality with prolonged injection-to-scan times. Mol Imaging Biol 2012, 14(2, supplement):610.
- [65]Lowe VJ, DeLong DM, Hoffman JM, Coleman RE: Optimum scanning protocol for FDG-PET evaluation of pulmonary malignancy. J Nucl Med 1995, 36:883-887.
- [66]Boerner AR, Weckesser M, Herzog H, Schmitz T, Audretsch W, Nitz U, Bender HG, Mueller-Gaertner HW: Optimal scan time for fluorine-18 fluorodeoxyglucose positron emission tomography in breast cancer. Eur J Nucl Med 1999, 26:226-230.
- [67]Hustinx R, Smith RJ, Benard F, Rosenthal DI, Machtay M, Farber LA, Alavi A: Dual time point fluorine-18 fluorodeoxyglucose positron emission tomography: a potential method to differentiate malignancy from inflammation and normal tissue in the head and neck. Eur J Nucl Med 1999, 26:1345-1348.
- [68]Lodge MA, Lucas JD, Marsden PK, Cronin BF, O’Doherty MJ, Smith MA: A PET study of 18FDG uptake in soft tissue masses. Eur J Nucl Med 1999, 26:22-30.
- [69]Nakamoto Y, Higashi T, Sakahara H, Tamaki N, Kogire M, Doi R, Hosotani R, Imamura M, Konishi J: Delayed (18) F-fluoro-2-deoxy-D-glucose positron emission tomography scan for differentiation between malignant and benign lesions in the pancreas. Cancer 2000, 89:2547-2554.
- [70]Kubota K, Itoh M, Ozaki K, Ono S, Tashiro M, Yamaguchi K, Akaizawa T, Yamada K, Fukuda H: Advantage of delayed whole-body FDG-PET imaging for tumour detection. Eur J Nucl Med 2001, 28:696-703.
- [71]Zhuang H, Pourdehnad M, Lambright ES, Yamamoto AJ, Lanuti M, Li P, Mozley PD, Rossman MD, Albelda SM, Alavi A: Dual time point 18F-FDG PET imaging for differentiating malignant from inflammatory processes. J Nucl Med 2001, 42:1412-1417.
- [72]Koyama K, Okamura T, Kawabe J, Ozawa N, Higashiyama S, Ochi H, Yamada R: The usefulness of 18F-FDG PET images obtained 2 hours after intravenous injection in liver tumor. Ann Nucl Med 2002, 16:169-176.
- [73]Matthies A, Hickeson M, Cuchiara A, Alavi A: Dual time point 18F-FDG PET for the evaluation of pulmonary nodules. J Nucl Med 2002, 43:871-875.
- [74]Conrad GR, Sinha P: Narrow time-window dual-point 18F-FDG PET for the diagnosis of thoracic malignancy. Nucl Med Commun 2003, 24:1129-1137.
- [75]Demura Y, Tsuchida T, Ishizaki T, Mizuno S, Totani Y, Ameshima S, Miyamori I, Sasaki M, Yonekura Y: 18F-FDG accumulation with PET for differentiation between benign and malignant lesions in the thorax. J Nucl Med 2003, 44:540-548.
- [76]Ma SY, See LC, Lai CH, Chou HH, Tsai CS, Ng KK, Hsueh S, Lin WJ, Chen JT, Yen TC: Delayed (18) F-FDG PET for detection of paraaortic lymph node metastases in cervical cancer patients. J Nucl Med 2003, 44:1775-1783.
- [77]Yen TC, Ng KK, Ma SY, Chou HH, Tsai CS, Hsueh S, Chang TC, Hong JH, See LC, Lin WJ, Chen JT, Huang KG, Lui KW, Lai CH: Value of dual-phase 2-fluoro-2-deoxy-d-glucose positron emission tomography in cervical cancer. J Clin Oncol 2003, 21:3651-3658.
- [78]Döbert N, Hamscho N, Menzel C, Neuss L, Kovács AF, Grünwald F: Limitations of dual time point FDG-PET imaging in the evaluation of focal abdominal lesions. Nuklearmedizin 2004, 43:143-149.
- [79]Kubota K, Yokoyama J, Yamaguchi K, Ono S, Qureshy A, Itoh M, Fukuda H: FDG-PET delayed imaging for the detection of head and neck cancer recurrence after radio-chemotherapy: comparison with MRI/CT. Eur J Nucl Med Mol Imaging 2004, 31:590-595.
- [80]Lai CH, Huang KG, See LC, Yen TC, Tsai CS, Chang TC, Chou HH, Ng KK, Hsueh S, Hong JH: Restaging of recurrent cervical carcinoma with dual-phase [18F] fluoro-2-deoxy-D-glucose positron emission tomography. Cancer 2004, 100:544-552.
- [81]Spence AM, Muzi M, Mankoff DA, O’Sullivan SF, Link JM, Lewellen TK, Lewellen B, Pham P, Minoshima S, Swanson K, Krohn KA: 18F-FDG PET of gliomas at delayed intervals: improved distinction between tumor and normal gray matter. J Nucl Med 2004, 45:1653-1659.
- [82]Chen YK, Kao CH: Metastatic hepatic lesions are detected better by delayed imaging with prolonged emission time. Clin Nucl Med 2005, 30:455-456.
- [83]Kumar R, Loving VA, Chauhan A, Zhuang H, Mitchell S, Alavi A: Potential of dual-time-point imaging to improve breast cancer diagnosis with (18) F-FDG PET. J Nucl Med 2005, 46:1819-1824.
- [84]Lin WY, Tsai SC, Hung GU: Value of delayed 18F-FDG-PET imaging in the detection of hepatocellular carcinoma. Nucl Med Commun 2005, 26:315-321.
- [85]Lyshchik A, Higashi T, Nakamoto Y, Fujimoto K, Doi R, Imamura M, Saga T: Dual-phase 18F-fluoro-2-deoxy-D-glucose positron emission tomography as a prognostic parameter in patients with pancreatic cancer. Eur J Nucl Med Mol Imaging 2005, 32:389-397.
- [86]Nishiyama Y, Yamamoto Y, Monden T, Sasakawa Y, Tsutsui K, Wakabayashi H, Ohkawa M: Evaluation of delayed additional FDG PET imaging in patients with pancreatic tumour. Nucl Med Commun 2005, 26:895-901.
- [87]Sanghera B, Wong WL, Lodge MA, Hain S, Stott D, Lowe J, Lemon C, Goodchild K, Saunders M: Potential novel application of dual time point SUV measurements as a predictor of survival in head and neck cancer. Nucl Med Commun 2005, 26:861-867.
- [88]So Y, Chung JK, Jeong JM, Lee DS, Lee MC: Usefulness of additional delayed regional F-18 Fluorodeoxy-Glucose Positron Emission Tomography in the lymph node staging of Non-Small Cell Lung Cancer patients. Cancer Res Treat 2005, 37:114-121.
- [89]Yen TC, Chang YC, Chan SC, Chang JT, Hsu CH, Lin KJ, Lin WJ, Fu YK, Ng SH: Are dual-phase 18F-FDG PET scans necessary in nasopharyngeal carcinoma to assess the primary tumour and loco-regional nodes? Eur J Nucl Med Mol Imaging 2005, 32:541-548.
- [90]Hamada K, Tomita Y, Ueda T, Enomoto K, Kakunaga S, Myoui A, Higuchi I, Yoshikawa H, Hatazawa J: Evaluation of delayed 18F-FDG PET in differential diagnosis for malignant soft-tissue tumors. Ann Nucl Med 2006, 20:671-675.
- [91]Kwee SA, Wei H, Sesterhenn I, Yun D, Coel MN: Localization of primary prostate cancer with dual-phase 18F-fluorocholine PET. J Nucl Med 2006, 47:262-269.
- [92]Mavi A, Urhan M, Yu JQ, Zhuang H, Houseni M, Cermik TF, Thiruvenkatasamy D, Czerniecki B, Schnall M, Alavi A: Dual time point 18F-FDG PET imaging detects breast cancer with high sensitivity and correlates well with histologic subtypes. J Nucl Med 2006, 47:1440-1446.
- [93]Nishiyama Y, Yamamoto Y, Fukunaga K, Kimura N, Miki A, Sasakawa Y, Wakabayashi H, Satoh K, Ohkawa M: Dual-time-point 18F-FDG PET for the evaluation of gallbladder carcinoma. J Nucl Med 2006, 47:633-638.
- [94]Zhu Z, Wang B, Cheng W, Cheng X, Cui R, Huo L, Dang Y, Fu Z: Endometrial and ovarian F-18 FDG uptake in serial PET studies and the value of delayed imaging for differentiation. Clin Nucl Med 2006, 31:781-787.
- [95]Nishiyama Y, Yamamoto Y, Kimura N, Miki A, Sasakawa Y, Wakabayashi H, Ohkawa M: Comparison of early and delayed FDG PET for evaluation of biliary stricture. Nucl Med Commun 2007, 28:914-919.
- [96]Núñez R, Kalapparambath A, Varela J: Improvement in sensitivity with delayed imaging of pulmonary lesions with FDG-PET. Rev Esp Med Nucl 2007, 26:196-207.
- [97]Xiu Y, Bhutani C, Dhurairaj T, Yu JQ, Dadparvar S, Reddy S, Kumar R, Yang H, Alavi A, Zhuang H: Dual-time point FDG PET imaging in the evaluation of pulmonary nodules with minimally increased metabolic activity. Clin Nucl Med 2007, 32:101-105.
- [98]Alkhawaldeh K, Bural G, Kumar R, Alavi A: Impact of dual-time-point (18) F-FDG PET imaging and partial volume correction in the assessment of solitary pulmonary nodules. Eur J Nucl Med Mol Imaging 2008, 35:246-252.
- [99]Arena V, Skanjeti A, Casoni R, Douroukas A, Pelosi E: Dual-phase FDG-PET: delayed acquisition improves hepatic detectability of pathological uptake. Radiol Med 2008, 113:875-886.
- [100]Basu S, Mavi A, Cermik T, Houseni M, Alavi A: Implications of standardized uptake value measurements of the primary lesions in proven cases of breast carcinoma with different degree of disease burden at diagnosis: does 2-deoxy-2-[F-18] fluoro-D-glucose-positron emission tomography predict tumor biology? Mol Imaging Biol 2008, 10:62-66.
- [101]Chen YM, Huang G, Sun XG, Liu JJ, Chen T, Shi YP, Wan LR: Optimizing delayed scan time for FDG PET: comparison of the early and late delayed scan. Nucl Med Commun 2008, 29:425-430.
- [102]Chen CJ, Lee BF, Yao WJ, Cheng L, Wu PS, Chu CL, Chiu NT: Dual-phase 18F-FDG PET in the diagnosis of pulmonary nodules with an initial standard uptake value less than 2.5. AJR Am J Roentgenol 2008, 191:475-479.
- [103]Dirisamer A, Halpern BS, Schima W, Heinisch M, Wolf F, Beheshti M, Dirisamer F, Weber M, Langsteger W: Dual-time-point FDG-PET/CT for the detection of hepatic metastases. Mol Imaging Biol 2008, 10:335-340.
- [104]Hu M, Yu JM, Liu NB, Liu LP, Guo HB, Yang GR, Zhang PL, Xu XQ: Significance of dual-time-point 18F-FDG PET imaging in evaluation of hilar and mediastinal lymph node metastasis in non-small-cell lung cancer. Zhonghua Zhong Liu Za Zhi 2008, 30:306-309.
- [105]Imbriaco M, Caprio MG, Limite G, Pace L, De Falco T, Capuano E, Salvatore M: Dual-time-point 18F-FDG PET/CT versus dynamic breast MRI of suspicious breast lesions. AJR Am J Roentgenol 2008, 191:1323-1330.
- [106]Lan XL, Zhang YX, Wu ZJ, Jia Q, Wei H, Gao ZR: The value of dual time point (18) F-FDG PET imaging for the differentiation between malignant and benign lesions. Clin Radiol 2008, 63:756-764.
- [107]Nishiyama Y, Yamamoto Y, Kimura N, Ishikawa S, Sasakawa Y, Ohkawa M: Dual-time-point FDG-PET for evaluation of lymph node metastasis in patients with non-small-cell lung cancer. Ann Nucl Med 2008, 22:245-250.
- [108]Uesaka D, Demura Y, Ishizaki T, Ameshima S, Miyamori I, Sasaki M, Fujibayashi Y, Okazawa H: Evaluation of dual-time-point 18F-FDG PET for staging in patients with lung cancer. J Nucl Med 2008, 49:1606-1612.
- [109]Yen RF, Chen KC, Lee JM, Chang YC, Wang J, Cheng MF, Wu YW, Lee YC: 18F-FDG PET for the lymph node staging of non-small cell lung cancer in a tuberculosis-endemic country: is dual time point imaging worth the effort? Eur J Nucl Med Mol Imaging 2008, 35:1305-1315.
- [110]Zytoon AA, Murakami K, El-Kholy MR, El-Shorbagy E: Dual time point FDG-PET/CT imaging. Potential tool for diagnosis of breast cancer. Clin Radiol 2008, 63:1213-1227.
- [111]Basu S, Kung J, Houseni M, Zhuang H, Tidmarsh GF, Alavi A: Temporal profile of fluorodeoxyglucose uptake in malignant lesions and normal organs over extended time periods in patients with lung carcinoma: implications for its utilization in assessing malignant lesions. Q J Nucl Med Mol Imaging 2009, 53:9-19.
- [112]Chin BB, Green ED, Turkington TG, Hawk TC, Coleman RE: Increasing uptake time in FDG-PET: standardized uptake values in normal tissues at 1 versus 3 h. Mol Imaging Biol 2009, 11:118-122.
- [113]Hu Q, Wang W, Zhong X, Yuan S, Fu Z, Guo H, Yu J: Dual-time-point FDG PET for the evaluation of locoregional lymph nodes in thoracic esophageal squamous cell cancer. Eur J Radiol 2009, 70:320-324.
- [114]Inoue A, Tomiyama N, Tatsumi M, Ikeda N, Okumura M, Shiono H, Inoue M, Higuchi I, Aozasa K, Johkoh T, Nakamura H, Hatazawa J: (18) F-FDG PET for the evaluation of thymic epithelial tumors: Correlation with the World Health Organization classification in addition to dual-time-point imaging. Eur J Nucl Med Mol Imaging 2009, 36:1219-1225.
- [115]Kim IJ, Kim SJ, Kim YS, Lee TH, Jeong YJ: Characterization of pulmonary lesions with low F-18 FDG uptake using double phase F-18 FDG PET/CT: comparison of visual and quantitative analyses. Neoplasma 2009, 56:33-39.
- [116]Laffon E, de Clermont H, Begueret H, Vernejoux JM, Thumerel M, Marthan R, Ducassou D: Assessment of dual-time-point 18F-FDG-PET imaging for pulmonary lesions. Nucl Med Commun 2009, 30:455-461.
- [117]Mavi A, Basu S, Cermik TF, Urhan M, Bathaii M, Thiruvenkatasamy D, Houseni M, Dadparvar S, Alavi A: Potential of dual time point FDG-PET imaging in differentiating malignant from benign pleural disease. Mol Imaging Biol 2009, 11:369-378.
- [118]Schillaci O, Travascio L, Bolacchi F, Calabria F, Bruni C, Cicciò C, Guazzaroni M, Orlacchio A, Simonetti G: Accuracy of early and delayed FDG PET-CT and of contrast-enhanced CT in the evaluation of lung nodules: a preliminary study on 30 patients. Radiol Med 2009, 114:890-906.
- [119]Shinya T, Rai K, Okumura Y, Fujiwara K, Matsuo K, Yonei T, Sato T, Watanabe K, Kawai H, Sato S, Kanazawa S: Dual-time-point F-18 FDG PET/CT for evaluation of intrathoracic lymph nodes in patients with non-small cell lung cancer. Clin Nucl Med 2009, 34:216-221.
- [120]Suga K, Kawakami Y, Hiyama A, Sugi K, Okabe K, Matsumoto T, Ueda K, Tanaka N, Matsunaga N: Differential diagnosis between (18) F-FDG-avid metastatic lymph nodes in non-small cell lung cancer and benign nodes on dual-time point PET/CT scan. Ann Nucl Med 2009, 23:523-531.
- [121]Suga K, Kawakami Y, Hiyama A, Sugi K, Okabe K, Matsumoto T, Ueda K, Tanaka N, Matsunaga N: Dual-time point 18F-FDG PET/CT scan for differentiation between 18F-FDG-avid non-small cell lung cancer and benign lesions. Ann Nucl Med 2009, 23:427-435.
- [122]Suga K, Kawakami Y, Hiyama A, Matsunaga N: Differentiation of FDG-avid loco-regional recurrent and compromised benign lesions after surgery for breast cancer with dual-time point F-18-fluorodeoxy-glucose PET/CT scan. Ann Nucl Med 2009, 23:399-407.
- [123]Su MG, Fan QP, Tian Y, Li FL, Yang XC, Li L, Fan CZ, Tian R: Differentiation of malignant and benign superficial lymph nodes by dual time point 18F-FDG PET. Sichuan Da Xue Xue Bao Yi Xue Ban 2009, 40:517-520.
- [124]Tian R, Su M, Tian Y, Li F, Li L, Kuang A, Zeng J: Dual-time point PET/CT with F-18 FDG for the differentiation of malignant and benign bone lesions. Skeletal Radiol 2009, 38:451-458.
- [125]Yamamoto Y, Kameyama R, Togami T, Kimura N, Ishikawa S, Yamamoto Y, Nishiyama Y: Dual time point FDG PET for evaluation of malignant pleural mesothelioma. Nucl Med Commun 2009, 30:25-29.
- [126]Wong CY, Noujaim D, Fu HF, Huang WS, Cheng CY, Thie J, Dalal I, Chang CY, Nagle C: Time sensitivity: a parameter reflecting tumor metabolic kinetics by variable dual-time F-18 FDG PET imaging. Mol Imaging Biol 2009, 11:283-290.
- [127]Zytoon AA, Murakami K, El-Kholy MR, El-Shorbagy E, Ebied O: Breast cancer with low FDG uptake: characterization by means of dual-time point FDG-PET/CT. Eur J Radiol 2009, 70:530-538.
- [128]Caprio MG, Cangiano A, Imbriaco M, Soscia F, Di Martino G, Farina A, Avitabile G, Pace L, Forestieri P, Salvatore M: Dual-time-point [18F]-FDG PET/CT in the diagnostic evaluation of suspicious breast lesions. Radiol Med 2010, 115:215-224.
- [129]Cloran FJ, Banks KP, Song WS, Kim Y, Bradley YC: Limitations of dual time point PET in the assessment of lung nodules with low FDG avidity. Lung Cancer 2010, 68:66-71.
- [130]Kasai T, Motoori K, Horikoshi T, Uchiyama K, Yasufuku K, Takiguchi Y, Takahashi F, Kuniyasu Y, Ito H: Dual-time point scanning of integrated FDG PET/CT for the evaluation of mediastinal and hilar lymph nodes in non-small cell lung cancer diagnosed as operable by contrast-enhanced CT. Eur J Radiol 2010, 75:143-146.
- [131]Kim DW, Jung SA, Kim CG, Park SA: The efficacy of dual time point F-18 FDG PET imaging for grading of brain tumors. Clin Nucl Med 2010, 35:400-403.
- [132]Sathekge MM, Maes A, Pottel H, Stoltz A, van de Wiele C: Dual time-point FDG PET-CT for differentiating benign from malignant solitary pulmonary nodules in a TB endemic area. S Afr Med J 2010, 100:598-601.
- [133]Alkhawaldeh K, Biersack HJ, Henke A, Ezziddin S: Impact of dual-time-point F-18 FDG PET/CT in the assessment of pleural effusion in patients with non-small-cell lung cancer. Clin Nucl Med 2011, 36:423-428.
- [134]Chan WL, Ramsay SC, Szeto ER, Freund J, Pohlen JM, Tarlinton LC, Young A, Hickey A, Dura R: Dual-time-point (18) F-FDG-PET/CT imaging in the assessment of suspected malignancy. J Med Imaging Radiat Oncol 2011, 55:379-390.
- [135]Choi WH, Yoo IR, O JH, Kim SH, Chung SK: The value of dual-time-point 18F-FDG PET/CT for identifying axillary lymph node metastasis in breast cancer patients. Br J Radiol 2011, 84:593-599.
- [136]Horky LL, Hsiao EM, Weiss SE, Drappatz J, Gerbaudo VH: Dual phase FDG-PET imaging of brain metastases provides superior assessment of recurrence versus post-treatment necrosis. J Neurooncol 2011, 103:137-146.
- [137]Hsiao YC, Wu PS, Chiu NT, Yao WJ, Lee BF, Peng SL: The use of dual-phase F-18-FDG PET in characterizing thyroid incidentalomas. Clin Radiol 2011, 66:1197-1202.
- [138]Hu M, Han A, Xing L, Yang W, Fu Z, Huang C, Zhang P, Kong L, Yu J: Value of dual-time-point FDG PET/CT for mediastinal nodal staging in non-small-cell lung cancer patients with lung comorbidity. Clin Nucl Med 2011, 36:429-433.
- [139]Kim SJ, Kim YK, Kim IJ, Kim YD, Lee MK: Limited predictive value of dual-time-point F-18 FDG PET/CT for evaluation of pathologic N1 status in NSCLC patients. Clin Nucl Med 2011, 36:434-439.
- [140]Kim SJ, Kim BH, Jeon YK, Kim SS, Kim IJ: Limited diagnostic and predictive values of dual-time-point 18F FDG PET/CT for differentiation of incidentally detected thyroid nodules. Ann Nucl Med 2011, 25:347-353.
- [141]Lee JW, Kim SK, Lee SM, Moon SH, Kim TS: Detection of hepatic metastases using dual-time-point FDG PET/CT scans in patients with colorectal cancer. Mol Imaging Biol 2011, 13:565-572.
- [142]Macdonald K, Searle J, Lyburn I: The role of dual time point FDG PET imaging in the evaluation of solitary pulmonary nodules with an initial standard uptake value less than 2.5. Clin Radiol 2011, 66:244-250.
- [143]Nakamura S, Okochi K, Kurabayashi T: Dual-time-point fluorodeoxyglucose positron emission tomography for diagnosis of cervical lymph node metastases in patients with head and neck squamous cell carcinoma. J Comput Assist Tomogr 2011, 35:303-307.
- [144]Prieto E, Martí-Climent JM, Domínguez-Prado I, Garrastachu P, Díez-Valle R, Tejada S, Aristu JJ, Peñuelas I, Arbizu J: Voxel-based analysis of dual-time-point 18F-FDG PET images for brain tumor identification and delineation. J Nucl Med 2011, 52:865-872.
- [145]Wang ZX, Zhang B, Wu YW, Ni B, Pan LD: The clinic value of (18) F-FDG PET/CT imaging in differentiation of malignant from benign disease in lung. Zhonghua Yi Xue Za Zhi 2011, 91:2456-2458.
- [146]Abe Y, Tamura K, Sakata I, Ishida J, Ozeki Y, Tamura A, Uematsu K, Sakai H, Goya T, Kanazawa M, Machida K: Clinical implications of 18F-fluorodeoxyglucose positron emission tomography/computed tomography at delayed phase for diagnosis and prognosis of malignant pleural mesothelioma. Oncol Rep 2012, 27:333-338.
- [147]Chiu CF, Lin YY, Hsu WH, Chen CY, Yeh JJ, Kao CH: Shorter-time dual-phase FDG PET/CT in characterizing solid or ground-glass nodules based on surgical results. Clin Imaging 2012, 36:509-514.
- [148]Elboga U, Yılmaz M, Uyar M, Zeki Çelen Y, Bakır K, Dikensoy O: The role of FDG PET-CT in differential diagnosis of pleural pathologies. Rev Esp Med Nucl Imagen Mol 2012, 31:187-191.
- [149]Fuster D, Lafuente S, Setoain X, Navales I, Perissinotti A, Pavia J, Paredes P, Lomeña F, Pons F: Dual-time point images of the liver with (18) F-FDG PET/CT in suspected recurrence from colorectal cancer. Rev Esp Med Nucl Imagen Mol 2012, 31:111-116.
- [150]Hahn S, Hecktor J, Grabellus F, Hartung V, Pöppel T, Kimmig R, Forsting M, Antoch G, Heusner TA: Diagnostic accuracy of dual-time-point 18F-FDG PET/CT for the detection of axillary lymph node metastases in breast cancer patients. Acta Radiol 2012, 53:518-523.
- [151]Li M, Wu N, Liu Y, Zheng R, Liang Y, Zhang W, Zhao P: Regional nodal staging with 18F-FDG PET-CT in non-small cell lung cancer: Additional diagnostic value of CT attenuation and dual-time-point imaging. Eur J Radiol 2012, 81:1886-1890.
- [152]Mertens LS, Fioole-Bruining A, Vegt E, Vogel WV, van Rhijn BW, Horenblas S: Detecting primary bladder cancer using delayed (18) F-2-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography imaging after forced diuresis. Indian J Nucl Med 2012, 27:145-150.
- [153]Miyake KK, Nakamoto Y, Togashi K: Dual-time-point 18F-FDG PET/CT in patients with colorectal cancer: clinical value of early delayed scanning. Ann Nucl Med 2012, 26:492-500.
- [154]Schillaci O: Use of dual-point fluorodeoxyglucose imaging to enhance sensitivity and specificity. Semin Nucl Med 2012, 42:267-280.
- [155]Shinya T, Fujii S, Asakura S, Taniguchi T, Yoshio K, Alafate A, Sato S, Yoshino T, Kanazawa S: Dual-time-point F-18 FDG PET/CT for evaluation in patients with malignant lymphoma. Ann Nucl Med 2012, 26:616-621.
- [156]Shum WY, Hsieh TC, Yeh JJ, Chen JH, Su CC, Liang JA, Kao CH: Clinical usefulness of dual-time FDG PET-CT in assessment of esophageal squamous cell carcinoma. Eur J Radiol 2012, 81:1024-1028.
- [157]Xu XX, Cheng J, Xu WG, Dai D, Song XY, Ma WC, Zhu L, Zhu X: Value of dual-time-point (18) F-fluorodeoxyglucose integrated positron emission and computed tomography in differentiation of malignant from benign gastrointestinal diseases. Zhonghua Zhong Liu Za Zhi 2012, 34:364-368.
- [158]Carlson ER, Schaefferkoetter J, Townsend D, McCoy JM, Campbell PD Jr, Long M: The use of multiple time point dynamic positron emission tomography/computed tomography in patients with oral/head and neck cancer does not predictably identify metastatic cervical lymph nodes. J Oral Maxillofac Surg 2013, 71:162-177.
- [159]Cheng G, Torigian DA, Zhuang H, Alavi A: When should we recommend use of dual time-point and delayed time-point imaging techniques in FDG PET? Eur J Nucl Med Mol Imaging 2013, 40:779-787.
- [160]Choi EK, Yoo IR, Kim SH OJH, Choi WH, Na SJ, Park SY: The clinical value of dual-time point 18F-FDG PET/CT for differentiating extrahepatic cholangiocarcinoma from benign disease. Clin Nucl Med 2013, 38:e106-e111.
- [161]Choi H, Yoon HJ, Kim TS, Oh JH, Kim DY, Kim SK: Voxel-based dual-time 18F-FDG parametric imaging for rectal cancer: differentiation of residual tumor from postchemoradiotherapy changes. Nucl Med Commun 2013, 34:1166-1173.
- [162]Costantini DL, Vali R, Chan J, McQuattie S, Charron M: Dual-time-point FDG PET/CT for the evaluation of pediatric tumors. AJR Am J Roentgenol 2013, 200:408-413.
- [163]Kadaria D, Archie DS, Sultanali I, Weiman DS, Freire AX, Zaman MK: Dual time point positron emission tomography/computed tomography scan in evaluation of intrathoracic lesions in an area endemic for histoplasmosis and with high prevalence of sarcoidosis. Am J Med Sci 2013, 346:358-362.
- [164]Kaneko K, Sadashima S, Irie K, Hayashi A, Masunari S, Yoshida T, Omagari J: Assessment of FDG retention differences between the FDG-avid benign pulmonary lesion and primary lung cancer using dual-time-point FDG-PET imaging. Ann Nucl Med 2013, 27:392-399.
- [165]Nakayama M, Okizaki A, Ishitoya S, Sakaguchi M, Sato J, Aburano T: Dual-time-point F-18 FDG PET/CT imaging for differentiating the lymph nodes between malignant lymphoma and benign lesions. Ann Nucl Med 2013, 27:163-169.
- [166]Toriihara A, Nakamura S, Kubota K, Makino T, Okochi K, Shibuya H: Can dual-time-point 18F-FDG PET/CT differentiate malignant salivary gland tumors from benign tumors? AJR Am J Roentgenol 2013, 201:639-644.
- [167]Yoon HJ, Kim SK, Kim TS, Im HJ, Lee ES, Kim HC, Park JW, Chang HJ, Choi HS, Kim DY, Oh JH: New application of dual point 18F-FDG PET/CT in the evaluation of neoadjuvant chemoradiation response of locally advanced rectal cancer. Clin Nucl Med 2013, 38:7-12.
- [168]García Vicente AM, Soriano Castrejón A, Cruz Mora MA, Ortega Ruiperez C, Espinosa Aunión R, León Martín A, González Ageitos A, Van Gómez López O: Dual time point 2-deoxy-2-[(18) F] fluoro-d-glucose PET/CT: Nodal staging in locally advanced breast cancer. Rev Esp Med Nucl Imagen Mol 2014, 33:1-5.
- [169]Tahari AK, Lodge MA, Wahl RL: Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions. J Med Imaging Radiat Oncol 2014. doi:10.1111/1754-9485.12154. [Epub ahead of print]
- [170]Warburg O, Posener K, Negelein E: The metabolism of the carcinoma cell. In The Mechanism of Tumors. 1st edition. Edited by Warburg O. New York: Richard R. Smith, Inc; 1931:129-169.
- [171]Warburg O: On the origin of cancer cells. Science 1956, 123(3191):309-314.
- [172]Weber G: Enzymology of cancer cells. N Engl J Med 1977, 296:486-493.
- [173]Merrall NW, Plevin R, Gould GW: Growth factors, mitogens, oncogenes and the regulation of glucose transport. Cell Signal 1993, 5:667-675.
- [174]Pauwels EK, Ribeiro MJ, Stoot JH, McCready VR, Bourguignon M, Mazière B: FDG accumulation and tumor biology. Nucl Med Biol 1998, 25:317-322.
- [175]Gambhir SS: Molecular imaging of cancer with positron emission tomography. Nat Rev Cancer 2002, 2:683-693.
- [176]Buck AK, Reske SN: Cellular origin and molecular mechanisms of 18F-FDG uptake: is there a contribution of the endothelium? J Nucl Med 2004, 45:461-463.
- [177]Frangioni JV: The problem is background, not signal. Mol Imaging 2009, 8:303-304.
- [178]Hoffman EJ, Phelps ME: An analysis of some of the physical aspects of positron transaxial tomography. Comput Biol Med 1976, 6:345-360.
- [179]Hamberg LM, Hunter GJ, Alpert NM, Choi NC, Babich JW, Fischman AJ: The dose uptake ratio as an index of glucose metabolism: useful parameter or oversimplification? J Nucl Med 1994, 35:1308-1312.
PDF