BMC Research Notes | |
Single incision device (TVT Secur) versus retropubic tension-free vaginal tape device (TVT) for the management of stress urinary incontinence in women: a randomized clinical trial | |
Magali Robert1  Lorel Dederer1  Stephen Kaye3  Jose Goncalves4  Magnus Murphy1  Jane Schulz2  Selphee Tang1  Sue Ross5  | |
[1] Department of Obstetrics and Gynecology, University of Calgary, Calgary, Alberta, Canada;Department of Obstetrics and Gynecology, University of Alberta, Edmonton, Alberta, Canada;Department of Obstetrics and Gynecology, Lions Gate Hospital, North Vancouver, British Columbia, Canada;Department of Obstetrics and Gynecology, Penticton Regional Hospital, Penticton, British Columbia, Canada;Cavarzan Chair of Mature Women’s Health Research and Innovation, Department of Obstetrics and Gynecology, Lois Hole Hospital, Royal Alexandra Hospital, University of Alberta, Edmonton, Alberta, Canada | |
关键词: Surgical treatment; Stress urinary incontinence; Single incision device; Randomized controlled trial; Effectiveness; | |
Others : 1091209 DOI : 10.1186/1756-0500-7-941 |
|
received in 2014-03-21, accepted in 2014-12-15, 发布年份 2014 | |
【 摘 要 】
Background
In 2006, Ethicon Inc. introduced a new minimally invasive single incision sling device for the surgical treatment of stress urinary incontinence, the Gynecare TVT Secur®. For device licensing, no new evidence of TVT Secur efficacy and safety was needed: rather evidence was provided of the long-term follow-up of patients who had a procedure using a predecate retropubic tension-free vaginal tape device. Before adopting TVT Secur into our routine clinical practice, we decided to evaluate it. The objective of our Canadian multi-centre pragmatic randomized controlled trial was to compare the effectiveness of the new single-incision device, TVT Secur, to the established TVT device, in terms of objective cure of stress urinary incontinence (SUI) at 12 months postoperatively. Other outcomes included: complications, symptoms, and incontinence-related quality of life.
Results
The sample size estimate for our trial was 300, but the trial stopped early because of poor recruitment. 74 women participated (40 allocated to TVT Secur, 34 to TVT). At 12 months postoperatively, 27/33(82%) of TVT Secur group were cured, compared with 25/28(89%) of the TVT group (relative risk 0.92, 95% confidence interval 0.75 to 1.13, p = 0.49). Most women reported little or no SUI symptoms (35/37(95%) vs 29/30(97%), >0.999). Quality of life improved significantly from baseline for both groups (IIQ-7 mean change −25 for both groups) but did not differ between groups (p = 0.880).
Conclusion
Our small randomized trial did not find statistically significant differences in outcomes between women allocated to the TVT Secur device versus those allocated to the TVT device for stress urinary incontinence. Despite the discontinuation of TVT Secur in March 2013 for commercial reasons, the importance of our study lies in making evidence available for the many women who had a TVT Secur device implanted and their physicians who may be considering alternative treatments. Our experience illustrates the difficulty of undertaking research on new licensed devices in a rapidly changing surgical specialty, and further highlights the need for research before licensing if surgeons and their patients are to be confident in the effectiveness and safety of new surgical devices.
Trial registration
ClinicalTrials.gov NCT00685217, 22 May 2008.
【 授权许可】
2014 Ross et al.; licensee BioMed Central.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
20150128170337165.pdf | 459KB | download | |
Figure 1. | 46KB | Image | download |
【 图 表 】
Figure 1.
【 参考文献 】
- [1]Santos IC, Gazelle GS, Rocha LA, Tavares JM: Medical device specificities: opportunities for a dedicated product development methodology. Expert Rev Med Devices 2012, 9(3):299-311.
- [2]Ostergard DR: Lessons from the past: directions for the future. Do new marketed surgical procedures and grafts produce ethical, personal liability, and legal concerns for physicians? Int Urogynecol J Pelvic Floor Dysfunct 2007, 18(6):591-598.
- [3]Ross S, Robert M, Harvey M-A, Farrell S, Schulz J, Wilkie D, Lovatsis D, Epp A, Easton B, McMillan B, Schachter J, Gupta C, Weijer C: Ethical issues associated with the introduction of new surgical devices or just because we can doesn't mean we should. J Obstet Gynaecol Can 2008, 30(6):508-513.
- [4]Abrams P, Blaivas JG, Stanton SL, Andersen JT: The standardization of terminology of lower urinary tract function recommended by the International Continence Society. Int Urogynecol J 1990, 1(1):45-58.
- [5]Farrell SA, Epp A, Flood C, Lajoie F, MacMillan B, Mainprize T, Robert M, Urogynaecology Committtee: The evaluation of stress incontinence prior to primary surgery. J Obstet Gynaecol Can 2003, 25:313-324.
- [6]Uebersax JS, Wyman JF, Shumaker SA, McClish DK, Fantl JA, Continence Program for Women Research Group: Short forms to assess life quality and symptom distress for urinary incontinence in women: the incontinence impact questionnaire and the urogenital distress inventory. Neurourol Urodyn 1995, 14:131-139.
- [7]Rogers RG, Coates KW, Kammerer-Doak D, Khalsa S, Qualls C: A short form of the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12). Int Urogynecol J Pelvic Floor Dysfunct 2003, 14(3):164-168.
- [8]Ross S, Robert M, Swaby C, Dederer L, Lier D, Tang S, Brasher P, Birch C, Cenaiko D, Mainprize T, Murphy M, Carlson K, Baverstock R, Jacobs P, Williamson T: Transobturator tape compared with tension-free vaginal tape for stress incontinence. a randomized controlled trial. Obstet Gynecol 2009, 114(6):1287-1294.
- [9]Ward KL, Hilton P, Browning J, for UK & Ireland TVT trial group: Prospective multicentre randomized trial of tension-free vaginal tape and colposuspension as primary treatment for stress incontinence. BMJ 2002, 325:67.
- [10]Ward KL, Hilton P, Browning J, for UK & Ireland TVT trial group: A prospective multicentre randomized trial of tension-free vaginal tape and colposuspension for primary urodynamic stress incontinence: Two-year follow-up. Am J Obstet Gynecol 2004, 190:324-331.
- [11]FitzGerald MP, Kenton K, Shott S, Brubaker L: Responsiveness of quality of life measurements to change after reconstructive pelvic surgery. Am J Obstet Gynecol 2001, 185:20-24.
- [12]Harvey M-A, Kristjansson B, Griffith D, Versi E: The incontinence impact questionnaire and the urogenital distress inventory: a revisit of their validity in women without urodynamic diagnosis. Am J Obstet Gynecol 2001, 185:25-31.
- [13]Robinson D, Pearce KF, Preisser JS, Dugan E, Suggs PK, Cohen SJ: Relationship between patient reports of urinary incontinence symptoms and quality of life measures. Obstet Gynecol 1998, 91:224-228.
- [14]Ross S, Soroka D, Karahalios A, Glazener CMA, Hay-Smith EJC, Drutz HP: Incontinence-specific quality of life measures used in trials of treatments for female urinary incontinence: a systematic review. Int Urogynecol J Pelvic Floor Dysfunct 2006, 17(3):272-285.
- [15]Staskin D, Kelleher C, Avery K, International Consultation on Incontinence Committee 5: Patient-reported outcome assessment. In Incontinence. 4th edition. Edited by Abrams P, Cardozo L, Khoury S, Wein A. Paris: Health Publications Ltd; 2009:363-412.
- [16]Schulz KF, Altman DG, Moher D, CONSORT Group: CONSORT 2010 statement for reporting parallel group randomized trials. Obstet Gynecol 2010, 115(5):1063-1070.
- [17]Barber MD, Weidner AC, Sokol AI, Amundsen CL, Jelovsek JE, Karram MM, Ellerkmann M, Rardin CR, Iglesia CB, Toglia M, Foundation for Female Health Awareness Research Network: Single-incision mini-sling compared with tension-free vaginal tape for the treatment of stress urinary incontinence: a randomized controlled trial. Obstet Gynecol 2012, 119(2 Pt 1):328-337.
- [18]Hanley J, Capewell J, Hagen S: Validity study of the severity index, a simple measure of urinary incontinence in women. BMJ 2001, 322(7294):1096-1097.
- [19]Andrada Hamer M, Larsson PG, Teleman P, Etén-Bergqvist C, Persson J: Short-term results of a prospective randomized evaluator blinded multicenter study comparing TVT and TVT-Secur. Int Urogynecol J 2011, 22(7):781-787.
- [20]Andrada Hamer M, Larsson PG, Teleman P, Bergqvist CE, Persson J: One-year results of a prospective randomized, evaluator-blinded, multicenter study comparing TVT and TVT Secur. Int Urogynecol J 2013, 24(2):223-229.
- [21]Wang YJ, Li FP, Wang Q, Yang S, Cai XG, Chen YH: Comparison of three mid-urethral tension-free tapes (TVT, TVT-O, and TVT-Secur) in the treatment of female stress urinary incontinence: 1-year follow-up. Int Urogynecol J 2011, 22(11):1369-1374.
- [22]Oliveira R, Botelho F, Silva P, Resende A, Silva C, Dinis P, Cruz F: Exploratory study assessing efficacy and complications of TVT-O, TVT-Secur, and Mini-Arc: results at 12-month follow-up. Eur Urol 2011, 59(6):940-944.
- [23]Hinoul P, Vervest HA, den Boon J, Venema PL, Lakeman MM, Milani AL, Roovers JP: A randomized, controlled trial comparing an innovative single incision sling with an established transobturator sling to treat female stress urinary incontinence. J Urol 2011, 185(4):1356-1362.
- [24]Masata J, Svabik K, Zvara K, Drahoradova P, El Haddad R, Hubka P, Martan A: Randomized trial of a comparison of the efficacy of TVT-O and single-incision tape TVT SECUR systems in the treatment of stress urinary incontinent women-2-year follow-up. Int Urogynecol J 2012, 23(10):1403-1412.
- [25]Hota LS, Hanaway K, Hacker MR, Disciullo A, Elkadry E, Dramitinos P, Shapiro A, Ferzandi T, Rosenblatt PL: TVT-Secur (Hammock) versus TVT-Obturator: a randomized trial of suburethral sling operative procedures. Female Pelvic Med Reconstr Surg 2012, 18(1):41-45.
- [26]Maslow K, Gupta C, Klippenstein P, Girouard L: Randomized clinical trial comparing TVT Secur system and trans vaginal obturator tape for the surgical management of stress urinary incontinence. Int Urogynecol J 2014, 25(7):909-914.
- [27]Bianchi-Ferraro AM, Jarmy-Di Bella ZI, Castro RD, Bortolini MA, Sartori MG, Girão MJ: Single-incision sling compared with transobturator sling for treating stress urinary incontinence: a randomized controlled trial. Int Urogynecol J 2013, 24(9):1459-1465.
- [28]Tommaselli GA, D'Afiero A, Di Carlo C, Formisano C, Fabozzi A, Nappi C: Tension-free vaginal tape-O and -Secur for the treatment of stress urinary incontinence: a thirty-six-month follow-up single-blind, double-arm, randomized study. J Minim Invasive Gynecol 2013, 20(2):198-204.
- [29]Tang X, Zhu L, Liang S, Lang J: Outcome and sexual function after transobturator tape procedure versus tension-free vaginal tape Secur: a randomized controlled trial. Menopause 2014, 21(6):641-645.
- [30]Bernasconi F, Napolitano V, Natale F, Leone V, Lijoi D, Cervigni M: TVT SECUR System: Final results of a prospective, observational, multicentric study. Int Urogynecol J 2012, 23(1):93-98.
- [31]Nambiar A, Cody JD, Jeffery ST: Single-incision sling operations for urinary incontinence in women. Cochrane Database Syst Rev 2014, 6:CD008709.
- [32]Mostafa A, Lim CP, Hopper L, Madhuvrata P, Abdel-Fattah M: Single-incision mini-slings versus standard midurethral slings in surgical management of female stress urinary incontinence: an updated systematic review and meta-analysis of effectiveness and complications. Eur Urol 2014, 65(2):402-427.
- [33]National Institute for Health Care Excellence: Single-incision sub-urethral short tape insertion for stress urinary incontinence in women. NICE interventional procedures guidance 2008. IPG262. http://www.nice.org.uk/guidance/ipg262 webcite (Accessed 11 December 2014)