期刊论文详细信息
BMC Musculoskeletal Disorders
Treatment of pelvic fractures through a less invasive ilioinguinal approach combined with a minimally invasive posterior approach
Ai-min Chen2  Liang-yu Zhao2  Tian-wen Ye2  Di Shen2  Lu Wang1  Lei Zhu2 
[1] Department of Orthopedic Surgery, Zhoushan Hospital, Zhejiang, China;Department of Orthopedic Trauma Surgery, Changzheng Hospital, The Second Military Medical University, 415 Fengyang Rd., Huangpu District, Shanghai, China
关键词: Ilioinguinal approach;    Minimally invasive approach;    Pelvic fractures;   
Others  :  1227720
DOI  :  10.1186/s12891-015-0635-x
 received in 2014-11-11, accepted in 2015-07-15,  发布年份 2015
【 摘 要 】

Background

Unstable pelvic fractures usually result from high-energy trauma. There are several treatment modalities available. The purpose of this study was to evaluate the clinical application of a new less invasive ilioinguinal approach combined with a minimally invasive posterior approach technique in patients with unstable pelvic fractures. We also address the feasibility, validity, and limitations of the technique.

Methods

Thirty-seven patients with unstable pelvic fractures were treated with our minimally invasive technique. The anterior pelvic ring fractures were treated with a less invasive ilioinguinal approach, and the sacral fractures were treated with a minimally invasive posterior approach. The clinical outcome was measured using the Majeed scoring system, and the quality of fracture reduction was evaluated. The patients were followed up for 13 to 60 months (mean, 24 months).

Results

Anatomical or near to anatomical reduction was achieved in 26 (70.3 %) of the anterior pelvic ring fractures and a satisfactory result was obtained in another 11(29.7 %). For the posterior sacral fractures, excellent reduction was obtained in 33 (89.2 %) of the fractures, with a residual deformity in the other 4 patients. One superficial wound infection and two deep vein thromboses occurred, all of which resolved with conservative treatment. The clinical outcome at one year was “excellent” in 29 patients and “good” in 8 patients (Majeed score).

Conclusions

The satisfactory results showed that a reduction and fixation of unstable pelvic fractures is possible through a combination of a limited ilioinguinal approach and posterior pelvic ring fixation. We believe our method is a new and effective alternative in the management of pelvic fractures.

【 授权许可】

   
2015 Zhu et al.

附件列表
Files Size Format View
Fig. 2. 79KB Image download
Fig. 2. 141KB Image download
Fig. 1. 92KB Image download
【 图 表 】

Fig. 1.

Fig. 2.

Fig. 2.

【 参考文献 】
  • [1]McMurtry R, Walton D, Dickinson D, Kellam J, Tile M. Pelvic disruption in the polytraumatized patient: a management protocol. Clin Orthop Relat Res. 1980;22–30.
  • [2]Mardanpour K, Rahbar M. The outcome of surgically treated traumatic unstable pelvic fractures by open reduction and internal fixation. J Inj Violence Res. 2013; 5:77-83.
  • [3]Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O'Brien PJ. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999; 13:107-113.
  • [4]Lindahl J, Hirvensalo E, Bostman O, Santavirta S. Failure of reduction with an external fixator in the management of injuries of the pelvic ring. Long-term evaluation of 110 patients. J Bone Joint Surg (Br). 1999; 81:955-962.
  • [5]Routt ML, Simonian PT, Grujic L. The retrograde medullary superior pubic ramus screw for the treatment of anterior pelvic ring disruptions: a new technique. J Orthop Trauma. 1995; 9:35-44.
  • [6]Gary JL, VanHal M, Gibbons SD, Reinert CM, Starr AJ. Functional outcomes in elderly patients with acetabular fractures treated with minimally invasive reduction and percutaneous fixation. J Orthop Trauma. 2012; 26:278-283.
  • [7]Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989;83–97.
  • [8]Collinge C, Coons D, Aschenbrenner J. Risks to the superior gluteal neurovascular bundle during percutaneous iliosacral screw insertion: an anatomical cadaver study. J Orthop Trauma. 2005; 19:96-101.
  • [9]Reilly MC, Bono CM, Litkouhi B, Sirkin M, Behrens FF. The effect of sacral fracture malreduction on the safe placement of iliosacral screws. J Orthop Trauma. 2003; 17:88-94.
  • [10]Routt ML, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma. 1997; 11:584-589.
  • [11]Tile M. Acute Pelvic Fractures: I. Causation and Classification. J Am Acad Orthop Surg. 1996; 4:143-151.
  • [12]Majeed SA. Grading the outcome of pelvic fractures. J Bone Joint Surg (Br). 1989; 71:304-306.
  • [13]Matta JM. Operative treatment of acetabular fractures through the ilioinguinal approach. A 10-year perspective. Clin Orthop Relat Res. 1994;10–19.
  • [14]Lindahl J, Hirvensalo E. Outcome of operatively treated type-C injuries of the pelvic ring. Acta Orthop. 2005; 76:667-678.
  • [15]van Veen IH, van Leeuwen AA, van Popta T, van Luyt PA, Bode PJ, van Vugt AB. Unstable pelvic fractures: a retrospective analysis. Injury. 1995; 26:81-85.
  • [16]Wild JJ, Hanson GW, Tullos HS. Unstable fractures of the pelvis treated by external fixation. J Bone Joint Surg Am. 1982; 64:1010-1020.
  • [17]Kregor PJ, Routt ML. Unstable pelvic ring disruptions in unstable patients. Injury. 1999; 30 Suppl 2:B19-B28.
  • [18]Patel VR, Menon DK, Pool RD, Simonis RB. Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg (Br). 2000; 82:977-983.
  • [19]Mason WT, Khan SN, James CL, Chesser TJ, Ward AJ. Complications of temporary and definitive external fixation of pelvic ring injuries. Injury. 2005; 36:599-604.
  • [20]Tucker MC, Nork SE, Simonian PT, Routt ML. Simple anterior pelvic external fixation. J Trauma. 2000; 49:989-994.
  • [21]Riemer BL, Butterfield SL, Diamond DL et al.. Acute mortality associated with injuries to the pelvic ring: the role of early patient mobilization and external fixation. J Trauma. 1993; 35:671-675.
  • [22]Letournel E. Fractures of the acetabulum. A study of a series of 75 cases. 1961. Clin Orthop Relat Res 1994:5–9.
  • [23]Letournel E. The treatment of acetabular fractures through the ilioinguinal approach. Clin Orthop Relat Res. 1993;62–76.
  • [24]Zobrist R, Messmer P, Levin LS, Regazzoni P. Endoscopic-assisted, minimally invasive anterior pelvic ring stabilization: a new technique and case report. J Orthop Trauma. 2002; 16:515-519.
  • [25]Vaidya R, Colen R, Vigdorchik J, Tonnos F, Sethi A. Treatment of unstable pelvic ring injuries with an internal anterior fixator and posterior fixation: initial clinical series. J Orthop Trauma. 2012; 26:1-8.
  • [26]Hiesterman TG, Hill BW, Cole PA. Surgical technique: a percutaneous method of subcutaneous fixation for the anterior pelvic ring: the pelvic bridge. Clin Orthop Relat Res. 2012; 470:2116-2123.
  • [27]Yu X, Tang M, Zhou Z, Peng X, Wu T, Sun Y. Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury. Int Orthop. 2013; 37:1547-1554.
  • [28]Routt ML, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995; 9:207-214.
  • [29]van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma. 2002; 53:44-48.
  • [30]Sar C, Kilicoglu O. S1 pediculoiliac screw fixation in instabilities of the sacroiliac complex: biomechanical study and report of two cases. J Orthop Trauma. 2003; 17:262-270.
  文献评价指标  